Get complete information related to latest Gi Barbed Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gi Barbed Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gi Barbed Wire Tenders.
Tender For auction sale of depot ferrous scrap - 98050126]scrap cond./released/unserviceable ms scrap such as cbc coupler bodies, angels channels, signal rods, dash pot, yokes, draft gears sets, ms sheets, winch for lc gate, lever lock, lever rods, pull rods, suspension tube, bracket cl, housing axle bearing, chequered plates, cbc operating handle, rail cutter, rel hook, anti roll bracket, dredger drum, chain, centering disc, ms liners, center pivot washer, center pivot ring, side frame key, adopter narrow jaw, anti roll bar, wear plate, adopter wide jaw, suspension rods ,equalizing stay, erc clips, rail flange, chain hook, rotary shield with bearings, sab parts, ls beam, hangers, brake levers, brake hangers, adapter broken, center pivot top, anvil, workout sab, plate screws, transformer body and its ms parts, knuckle, fabricated test rig, gear wheel, anchor link, brake beam cut parts, axle box housing, bearing plates, rivette, chair plate, ms bed plate, ms gauge tie plate, structure bar, ms tie plates, slide chaires, center pivot, tamping tools, jim crow, cribs, track machine parts, locking plate, operating handle, cbc lock, cbc yoke, lower spring sheet beam, rail tong, center beams, screw couplings, lower spring sheet beam, cut pieces of pipes, buffers, buffer plungers, buffer casings, draw gear hooks, iron rods, wire, bolt & nut and other items coming under ms scrap on as is where is condition is available under the custody of cdms 08 ward ap. note: 1.pick and choose of the material are not allowed. loading to be started from one end and to be ended on other end only.(loc:bin no. 121 at scrap yard)
Tender For mazra khurd , anawas , sigri , group of 3 no. of habitations annual mtc.works for water supply - na cautionary sign boards gibarbedwire fencing 3. fencing with welded steel wire fabric 75 mm x 50 mm providing 1.20 metre high fencing with angle iron posts 50 mm x 50 mm x 6 mm at 3 metre centre to centre with 0.40 metre embedded in m15 grade cement concrete, corner, end and every 10th post to be strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or 75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and bolts etc. complete in all respects. i) adopt any one type of welded steel wire fabric 75 x 50 mm or 75 x 25 mm as per approved design. ii) the item of excavation and cement concrete in foundation shall be measured and paid separately
Tender For mazra khurd , anawas , sigri , group of 3 no. of habitations annual mtc.works for water supply - na cautionary sign boards gibarbedwire fencing 3. fencing with welded steel wire fabric 75 mm x 50 mm providing 1.20 metre high fencing with angle iron posts 50 mm x 50 mm x 6 mm at 3 metre centre to centre with 0.40 metre embedded in m15 grade cement concrete, corner, end and every 10th post to be strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or 75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and bolts etc. complete in all respects. i) adopt any one type of welded steel wire fabric 75 x 50 mm or 75 x 25 mm as per approved design. ii) the item of excavation and cement concrete in foundation shall be measured and paid separately
Tender For mazra khurd , anawas , sigri , group of 3 no. of habitations annual mtc.works for water supply - na cautionary sign boards gibarbedwire fencing 3. fencing with welded steel wire fabric 75 mm x 50 mm providing 1.20 metre high fencing with angle iron posts 50 mm x 50 mm x 6 mm at 3 metre centre to centre with 0.40 metre embedded in m15 grade cement concrete, corner, end and every 10th post to be strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or 75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and bolts etc. complete in all respects. i) adopt any one type of welded steel wire fabric 75 x 50 mm or 75 x 25 mm as per approved design. ii) the item of excavation and cement concrete in foundation shall be measured and paid separately
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For material supply for the installation of 4 line hanging solar power fence at rajapuram estate - hanging solar power fence, p.p reel insulator , must be of virgin plastic metirial. polypropylene or equivalent with break down voltage of 15 kv(weight 25gm avg, length 4.6 cm avg), strain insulator, must of poly polypropylene plastic rated for 15 kv uv stabillized ,(weight 40 gm avg, length 7 cm avg), gi post 12 feet , 2" gi pipe, 14 guage thickness,total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6 mm at end of bend pipe, intermediate post (t angle post) , 6ft., painted(25mm*25mm*3mm)having holes of size 6 mm at required interval of fencing installation, supporting post, 10ft.,gi-1,14 guage thickness,painted, stay (t angle), 2ft., painted(25mm*25mm*3mm), 12 swg ht wire, 12 guage,2.5 mm dia high tensile wire with zinc coating for use as conducting wires,binding strain insulator, 14 swg binding wire , high quality zinc coating wire for binding reel insulator, tighing support post with corner post, 1.5 mm stainless steel wire rop 304 grade, aluminium ferruel, aluminium ferruel 3 mm, wire tightner , permanat wire tightner made of special aluminium alloy designed for kv, uv stabillized, earth rod, copper plated earth rod 14 mm -3ft. length, earthing compound, earthing compound 8 kg, gate handle, gate handle and spring assembly, handle made of polyethylene, leadout cable,leadout cable for fence system double insulated gi cable inner core wire 2 sq.mm.hot dipped galvanised steel core, capaie of with standing 15kv should be provided to prevent bimetal salt formation at connections, single core 2.5 mm sq. cable, 2.5 mm2 single core copper cable for connecting the solar panel to the tubular battery through charge control unit with required terminal sockets,nut and bolt,washer, lightning diverter, 15kv -50kv rod gap arrester,must be capable of diverting stray lightning and adjustable for spark gaps adequate earthing to be provided, 100 watt solar panel, 100 watt/12 volt and above poly cristalline with 10 year warranty having iec/mnre certification, charge control unit, 20 a,12/24 pwm charge controller unit of standard make suitable to control the charging of the tubular battery, energizer, energizer with 10 kv output safety standards to be followed are bis 302-2-76 iec60335-2-76. switch-high, medium and low power setting., fence alarm system, fence alarm system covering area of 1.5 km, solar panel sapporting stand with metal box painted (for battery and energiser), 18 guage thickness metal box(lockable). gi-sheet, painted should be capable of housing battery, charge controller and energizer and fixed with reguired clamps and nut and bolt on solar panel suppoert stand made of gi pipe of 50mm diamere and b class type with suitable arreangement for holding the panel, warning sign, polyethylene plastic with satuatory wrning with signs, tubular battery 12v , 100ah, 12 v, 100 ah c10 rating with full 5 year replacement warranty (tower battery) for energising the energiser