Get complete information related to latest Gi Hook Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gi Hook Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gi Hook Tenders.
Tender For corrigendum : manufacture, fabrication, supply,erection, testing and commissioning with 1x8 mva pr.tr,stn transformer, associated equipments, accessories, control panels, control room and electrical works at o.krishnapuram in trichy metro under tkc thro e tener - electrical material supply, power transformer 33/11kv, 8mva power transformer with oltc, breaker along with ct for outdoor ss 33 kv (gc) vcb (out door) 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (600-300/1-1a) with structure and complete accessories with breaker platform., 11kv (lv) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulatedwith permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (1200-600/1-1a) with structure and complete accessories with breaker platform., 11kv (feeder) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (400-200/1-1a) with structure and complete accessories with breaker platform., potential transformer 33kv potential transformer with tc (single phase unit), 11kv potential transformer with tc (three phase unit), panels ac panel for 33kv ss, 110 v dc annunciation panel type b, 110v dc indoor c&r panel for gc breaker, 110v dc indoor c&r panel for lv breaker, 110 v dc indoor c&r panel for twin feeder, control cables, junction box and accessories 14c x 2.5 sq.mm copper cable armoured, 8c x 4 sq.mm copper cable armoured, 4c x 4 sq.mm copper cable armoured, 4c x 2.5 sq.mm copper cable armoured, 2c x 2.5 sq.mm copper cable armoured, isi mark 19 / 22 mm cable gland as directed by the field engineer., isi mark 25 mm cable gland as directed by the field engineer., isi mark cable 28 mm gland as directed by the field engineer., lugs, ferrules, sleeves, cable tie, insulation tape and other accessories for providing cable core end termination, supply of gi chequerred plate 6mm thickness, junction box supply of ct/pt junction box made out of 14swg (2mm) m.s.sheet wherever required as directed by the field engineer. the box shall be vermin proof shall have sturdy hinges, provision for mounting terminal blocks and locking arrangements including cost of all materials. 400w x 300h x 150d, supply of ac junction box of size 535x310x127mm of 18swg ms sheet including hrc fuse unit-18 nos. should be fitted with base, consumables etc. (the box shall be vermin proof, shall have sturdy hinges and locking arrangements), supply of mounting channel suitable for cbtm 5 terminal block in panel /box as required and as directed by the field engineer., supply of disconnected type terminal block suitable for ct circuits in panels/ box as required & as directed by the field engineer, supply of isi mark bakelite hrc fuse holder with fuse of 2/5/10/16 amps reputed make in panels/ boxes for ac/dc/pt circuits wherever required as directed by the field engineer. 16 amps - fuse holder with hrc fuse, 63amps - fuse holder with hrc fuse, bus & bus materials zebra acsr conductor, 2.0" / 50 mm aluminium bus bar (thickness:5 mm), 22/33 kv pt insulators, 11kv pt insulator, 11kv, 120kn disc insulators (antifog), strung bus eye bolt of 18 - 20 mm dia gi rod of required length suitable for 33kv, 22kv and 11kv strung bus including cost of gi rod and 2nos gi nuts & washer as directed by the field engineer., clamps and connectors tension fitting clamp 4 bolted for zebra, t clamp for 2" bus to single zebra, t clamp for zebra to zebra, switchend clamp for single zebra, switchend clamp for 2" busbar, reducer clamp for 2" bus to zebra, pg clamp for zebra, free end clamp for 2"busbar, corana bell for 50mm bus bar, switch end clamp for mink, seating block for 2" bus bar(for g
Tender For maintenance- repairs- replacement of electrical items for various projects executed under srinagar smart city limited for a period of 2 years. - supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage, delivery and erection of following sizes of distribution transformer at site., i) 630 kva distribution transformer, ii) 400 kva distribution transformer, iii) 250 kva distribution transformer, iv) 100 kva distribution transformer, v) 63 kva distribution transformer, fixing of fabricated gi angle/channel/flat/pole collars., fixing of galvanised nuts and bolts., supply, installation, testing, commissioning, insurance, unloading, carriage and delivery at site, laying, stringing and binding of conductor including joints with pg clamps of required following size of acsr conductor (0.1 /0.05/ 0.03), i) 100 sqmm acsr (dog), ii) 50 sqmm acsr (rabbit), iii) 30 sqmm acsr (weasel), supply, installation, testing, commissioning of ab (ht) cable of following sizes:, iii) 50 mm ab (ht) cable (3x50+1x70 mm ) xlpe(11 kv, 3c +earth), iv) 70 mm ab (ht) cable (3x70+1x95 mm ) xlpe(11 kv, 3c +earth), v) 95 mm ab (ht) cable (3x95+1x95 mm ) xlpe(11 kv, 3c +earth), vi) 120 mm ab (ht) cable (3x120+1x95 mm ) xlpe(11 kv, 3c +earth), mid span straight through jointing kit for 11 kv abc of following sizes:, i) 11 kv abc 50-95mm straight through jointing kit (3 core), ii) 11 kv abc 120-185mm straight through jointing kit (3 core), iii) 11 kv abc 240-300mm straight through jointing kit (3 core), heat shrinkable outdoor cable termination kit for ht/lt abc of following sizes:, i) 11 kv abc 70-95 mm outdoor cable termination kit, ii) 11 kv abc 120 mm outdoor cable termination kit, iii) 11 kv abc 150-185 mm outdoor cable termination kit, iv) 11 kv abc 240-300 mm outdoor cable termination kit, supply, installation, testing, commissioning of ab (lt) cable of following sizes:, ii) 50 mm ab (lt) cable ( 3x50 + 1 x 16 + 1 x 35) mm xlpe (1.1kv, 3+1 c, al), iii) 70 mm ab (lt) cable (3 x 70 + 1 x 16 + 1 x 50) mm xlpe (1.1kv, 3+1 c, al), iv) 120 mm ab (lt) cable (3 x 120 + 1 x 25 + 1 x 95) mm xlpe (1.1kv, 3+1 c, al), straight through cable jointing kit for lt abc of following sizes:, ii) 50 mm ab (lt)straight through cable jointing kit, iii) 70 mm ab (lt)straight through cable jointing kit, iii) 120 mm ab (lt)straight through cable jointing kit, dismantling, i) dismantling, stacking of 9/8 mtr st poles and transportation back to divisional store as per the instruction of electrical incharge., ii) dismantling of 0.03/0.05/0.1 acsr conductor and transportation to divisional stores (servicible), servo voltage stabilizer, i) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 63 kva, 3-phase oil cooled servo (complete job), ii) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 50 kva, 3-phase oil cooled servo (complete job), rmu, supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 4 way type,two isolators and two circuit breakers 11 kv, ring main unit ,sf6 insulated, out-door type, extensible type,breaking capacity 25 ka for one second with sf6 circuit breaker / vcb self powered with o/c + e/f relay comprising of a) 11kv 630 amp motorised isolator including earthing switches with making capacity 52ka, having mechanical on/off, earth indications with fault current indicator.b) 11kv ,400 amp motorised spring operated, circuit breakers with earthing switches, connecting the rmu to supply transformer. c). copper bus bar of 630 amp rating.d). 1 no numerical aux. powered relay having non directional o/c and e/f protection (for each ciruit breaker).d). the circuit breaker enclosures shall be outfitted with a communicable-type numerical (feeder p