Get complete information related to latest Girth Gear Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Girth Gear Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Girth Gear Tenders.
Tender For supply of supply installation and commissioning of 20 mtr polygonal high mast lighting with gear box , providing fabrication supply erection and fixing of gi pipe frame for flood light mounting , supply installation of 195w led flood light fitting with narrow beam optics , supply and installatiion of double drum winch with 3 hp motor and control panel for high mast lightinh system , 4 sqmm 5 core copper flexible cable , 1 point 5 sqmm 3 core cpper flexible cable
Tender For supply of motorized hydraulic stacker with stand 2 tontrolly width 545 x length 1150mm trolley normal conduction height 80 to 90mm, lifting total height 190 to 200mm m34 bolt stock length 150mm, chain drive make gear box motor 220v 1 32a 50hz, single phase rpm control 0 to 10 rpm refer attached drawing for further details. drawing no. j & td/cw/per/sk-1737 [ warranty period: 12 months after the date of delivery ] ]
Tender For spare parts of scania - connector 1/4" part no 140523, oil collector part no 257319, hand brake valve part no 249914, switch, foot dipper part no 159656, stop light switch part no 158717, t-connector part no 229020, air dryer part no 258985, charging valve part no 215619, elbow connector part no 146235, elbow connector part no 229704, pressure regul. valve part no 5360042991(230787), safety valve part no 293542, valve seat part no 229358, repair kit part no 263664, repair kit part no 263667, bumper part no 249727, stop part no 217280, contact holder part no 235650, sliding contact part no 130770, cap lower part part no 1102372, cap upper part part no 1102371, oil container part no 197804, hydraulic oil pump part no 259310, relay part no 371912, comp circuit part no 259240, relay part no 173554, block terminal part no 353489, socket part no 255080, starting socket part no 231631, battery main switch part no 197811, gear selector (gear box) part no 6695000734(393779), gear selector (transfer box) part no 5895022571(393777), tandom driving cable part no 1149732, bulb 2w/24v part no 258491, panel, switches part no 248821, panel, control lamps part no 248820, map reading lamp part no 218412, control lamp oil pressure part no 239170, control lamp full beam part no 239173, light filter part no 246680, control lamp (direct indicator i) part no 239174, control lamp (gear box oil temp) part no 255073, control lamp coolant temp part no 246856, control lamp (reversing light) part no 249300, plate, blackout lighting part no 391567, techometer part no 258660, comb instrument part no 268353, oil pressure gauge part no 259794, water temp gauge part no 249108, fuel gauge part no 249109
Tender For supply of cooling tower spares & service cooling tower no. 1, spares parts of cooling tower ,ac b eliminator 71 ,ac b eliminator 58 ,r.c.c. spacer ,s.s. wire grid 44 y76 (14 swg )(4 x 12 ) 1hw01194 ,pvc v bar 8 8 , code mpf01047 ,cable tie 6 ,target nozzle ,s.s. wire 14 swg ,work details;- *dismantling & re- fitting of s.s. wire grid & pvc v bar properly in all respect. *dismantling & re-fitting after cleaning of acb drift eliminator along with ,rcc spacer complete in all respect. *binding of s.s. wire grid with rcc beam should be properly done. *fitting of target nozzles at position should be done. *cell ,repairing all work should be done completely to insure the trouble free working of cooling tower during the season. *minor repairing jobs for other cells also to be done. ,spares for paharpur cooling tower model 1400-02-(16 at) ,spare coupling with distance shaft pipe (for gear box to motor connection)flange, flow control (f.c) valve size 12 dia.
Tender For supply of bush holder , back light switch , armature assy , field coil assy , solenoid valve , hose pipe , exhaust break cyl assy , oil seal , air compressor ring , rod spring bush , centre bolt , break booster kit , needle bearing , vane pump , packing kit , distributor head assy , knuckle bush , thrust bearing , hand control valve , air filter , oil filter , fuel filter , gear box seal kit
Tender For corrigendum : annual operation & day to day maintenance of internal & external e&m installations at goa international airport for the year 2026-2028. - servicing, testing and checking of breakers , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 800-1600 a " , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 2000 a - 2500a " , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 3200a - 4000a , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. schneider make acb of following rating , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. ge make acb of following rating , one time servicing, checking and testing of 33kv vaccum circuit breakers (vcb) including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. make jyoti , servicing, checking and calibration of the following relays as per recommended standards and submission of calibration report complete as required through authorised agency of oem / agency approved by engineer-in-charge. , servicing of 3x 4kw grundfos make hydropneumatic pumps along with control panel which includes cleaning, safety check, motor, gear box, drive check, vfd parameters check etc. as per oem recommendation through oem or authorised service partner of oem. , servicing of 0.55 kw - 5kw grundfos make pumps which includes cleaning, safety check, motor, gear box, drive check etc. as per oem recommendation through oem or authorised service partner of oem. , dehydration & filteration of transformer oil of 1000 kva transformer of aai residential colony to improve the breakdown voltage of oil up to 50 kv by oil filtration machine and carrying out bdv test of oil, top up of transformer oil etc. by keeping the dehydration equipment out side the 33kv yard including transportation of filtration machine up to site etc. complete as required (excluding the cost of transformer oil). , "the execution of items mentioned in cpwd, delhi schedule of rates (e&m) 2025 for electrical repair and maintenance of electrical e&m installations as and when required as per direction of engineer-in-charge at goa airport for period of two years. agency will quote against basic rate of rs. 5,00,000.00 (say x) (including gst) in ""rate column"" for examples : (i) if bidder is quoting rs. 4,00,000.00 (including gst) (y1) then it will be