Tender For supply of 25 kv drop out fuse element capacity 1 amp,tie rod insulator used in manually operated 25kv isolator and capacitor bank support insulator 24 kv
Tender For the work of shifting of line full deposite scheem at various place under edd-sadabad hathras. - safe carriage of following material from electricty store center hts to pit site of work through the kacha and pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, t&p, etc. which required for proper completion of work.(distance 00-50 kms.), 8.5/9 mtr. long pcc poles., 9/11 mtr. s.t. poles, acsr weasel conductor, earthing complete, shackle insulator, stay set complete, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, 50/95/120 sqmm. ab cable, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, guarding angle with clamp, g.i wire 6/8/10 swg, neutral cum earth wire, cable jointing kit, 11 kv xlpe cable, 25 kva t/f, 63 kva t/f, 100 kva t/f, errection of following poles including cutting of kharanja/mettalic road/concrete portion while digging pit & complete h.t./l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work., pcc poles 8.5/9 mtr., stp 9.0/11 mtr., errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost., fixing of earthing rod as per respo norms and as per direction of supervising engineer., safe installation of following new/repaired cousted t/f on newly constructed double pole in proper alignment direction & making all ht/lt connection., 25 kva t/f, 63 kva t/f, 100 kva t/f, laying, sagging and stringing and jumpering / binding etc. of new & old acsr weasal conductor / gi in 11 kv / lt lines as per respo manual and as per direction of supervising engineer., acsr weasal conductor, 50/95/120 sqmm. ab cable, xlpe cable, providing & fixing of following clamps, 11 kv x arms clamps for stp/pcc pole, nut,bolt & washer, 11 kv f clamp for stp/pcc pole, earthwire clamps, lt clamp with nut & bolt, cable jointing kit, cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer, guarding/reguarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x-guards (tillis) of gi wire at distance of 3 mtr., installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the "t" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material., dismentlling and removal of existing line from the various area, dismentlling of pole stp/pcc, back cartage, acsr weasel conductor scrap, iron scrap
Tender For the work of construction of line and other associate work under full deposite scheme at various place under eudd-hathras. - safe carriage of following material from electricty store center hts to pit site of work through the kacha and pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, t&p, etc. which required for proper completion of work.(distance 00-50 kms.), 8.5/9 mtr. long pcc poles., 9/11 mtr. s.t. poles, acsr weasel conductor, earthing complete, shackle insulator, stay set complete, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, 50/95/120 sqmm. ab cable, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, guarding angle with clamp, g.i wire 6/8/10 swg, metering cubicle, ct-pt, 11 kv xlpe cable, 25 kva t/f, 63 kva t/f, 100 kva t/f, errection of following poles including cutting of kharanja/mettalic road/concrete portion while digging pit & complete h.t./l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work., pcc poles 8.5/9 mtr., stp 9.0/11 mtr., errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost., fixing of earthing rod as per respo norms and as per direction of supervising engineer., safe installation of following new/repaired cousted t/f on newly constructed double pole in proper alignment direction & making all ht/lt connection., 25 kva t/f, 63 kva t/f, 100 kva t/f, fixing/ errection of following item, cost of labor, material and t&p which required for completion of work, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, metering cubicle, ct-pt, laying, sagging and stringing and jumpering / binding etc. of new & old acsr weasal conductor / gi in 11 kv / lt lines as per respo manual and as per direction of supervising engineer., acsr weasal conductor, 50/95/120 sqmm. ab cable, xlpe cable, providing & fixing of following clamps, 11 kv x arms clamps for stp/pcc pole, nut,bolt & washer, 11 kv f clamp for stp/pcc pole, earthwire clamps, lt clamp with nut & bolt, cable jointing kit, cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer, guarding/reguarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x-guards (tillis) of gi wire at distance of 3 mtr., installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the "t" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material., dismentlling and removal of existing line from the various area, dismentlling of pole stp/pcc, back cartage, acsr weasel conductor scrap, iron scrap
Tender For corrigendum : manufacture, fabrication, supply,erection, testing and commissioning with 1x8 mva pr.tr,stn transformer, associated equipments, accessories, control panels, control room and electrical works at o.krishnapuram in trichy metro under tkc thro e tener - electrical material supply, power transformer 33/11kv, 8mva power transformer with oltc, breaker along with ct for outdoor ss 33 kv (gc) vcb (out door) 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (600-300/1-1a) with structure and complete accessories with breaker platform., 11kv (lv) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulatedwith permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (1200-600/1-1a) with structure and complete accessories with breaker platform., 11kv (feeder) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (400-200/1-1a) with structure and complete accessories with breaker platform., potential transformer 33kv potential transformer with tc (single phase unit), 11kv potential transformer with tc (three phase unit), panels ac panel for 33kv ss, 110 v dc annunciation panel type b, 110v dc indoor c&r panel for gc breaker, 110v dc indoor c&r panel for lv breaker, 110 v dc indoor c&r panel for twin feeder, control cables, junction box and accessories 14c x 2.5 sq.mm copper cable armoured, 8c x 4 sq.mm copper cable armoured, 4c x 4 sq.mm copper cable armoured, 4c x 2.5 sq.mm copper cable armoured, 2c x 2.5 sq.mm copper cable armoured, isi mark 19 / 22 mm cable gland as directed by the field engineer., isi mark 25 mm cable gland as directed by the field engineer., isi mark cable 28 mm gland as directed by the field engineer., lugs, ferrules, sleeves, cable tie, insulation tape and other accessories for providing cable core end termination, supply of gi chequerred plate 6mm thickness, junction box supply of ct/pt junction box made out of 14swg (2mm) m.s.sheet wherever required as directed by the field engineer. the box shall be vermin proof shall have sturdy hinges, provision for mounting terminal blocks and locking arrangements including cost of all materials. 400w x 300h x 150d, supply of ac junction box of size 535x310x127mm of 18swg ms sheet including hrc fuse unit-18 nos. should be fitted with base, consumables etc. (the box shall be vermin proof, shall have sturdy hinges and locking arrangements), supply of mounting channel suitable for cbtm 5 terminal block in panel /box as required and as directed by the field engineer., supply of disconnected type terminal block suitable for ct circuits in panels/ box as required & as directed by the field engineer, supply of isi mark bakelite hrc fuse holder with fuse of 2/5/10/16 amps reputed make in panels/ boxes for ac/dc/pt circuits wherever required as directed by the field engineer. 16 amps - fuse holder with hrc fuse, 63amps - fuse holder with hrc fuse, bus & bus materials zebra acsr conductor, 2.0" / 50 mm aluminium bus bar (thickness:5 mm), 22/33 kv pt insulators, 11kv pt insulator, 11kv, 120kn disc insulators (antifog), strung bus eye bolt of 18 - 20 mm dia gi rod of required length suitable for 33kv, 22kv and 11kv strung bus including cost of gi rod and 2nos gi nuts & washer as directed by the field engineer., clamps and connectors tension fitting clamp 4 bolted for zebra, t clamp for 2" bus to single zebra, t clamp for zebra to zebra, switchend clamp for single zebra, switchend clamp for 2" busbar, reducer clamp for 2" bus to zebra, pg clamp for zebra, free end clamp for 2"busbar, corana bell for 50mm bus bar, switch end clamp for mink, seating block for 2" bus bar(for g
Tender For supply of 4500nos of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure pole [excluding c
Tender For corrigendum : supply of 11kv abs components - 11 kv 400 a abs components ( please refer technical details on general terms and conditions of the tender), hot dip galvanized base channel, hot dip galvanized ms cast iron roller, hot dip galvanized side plate for roller assembly, brass bush bearing, hot dip galvanized contact guard, 6 turns phosphorous coiled spring, hot dip galvanized fixed arching horn, hot dip galvanized moving arching horn, hot dip galvanized pentograph assembly, 12 turns coiled spring, hot dip galvanized top clavis assembly, hot dip galvanized intermediate guide, hot dip galvanized operating handle assembly, hot dip galvanized 25mm sq operating shaft 2 meter, hot dip galvanized ms l clamp for moving contact, hot dip galvanized ms l clamp forterminal pad, 33.7 mm outer dia 30mm inner dia b class gi pipe 6 mtr, hot dip galvanized polymer insulator end fittings, copper rivet, hot dip galvanized ms rivet for spring guide, frp rod, silicon polymer raw material for injuction moulding