Get complete information related to latest Glow Plug Timer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Glow Plug Timer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Glow Plug Timer Tenders.
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; repair of large screen display model db 55e 55 inch; service provider
Tender For supply of main board logic card , sensor cable , pickup rubber , head cable , gear set roller , hp all in one display screen 24 inch , teflon , pressure roller , fuser assy gear set , dvd writer , right plate unit , head carriage , asf assy unit , heat roller , ops drum , cleaning blade , spare lock set , pcb board , slim dvd writer , key board and mouse
Tender For supply of wire rope , wiper moter , horn 12 volt , fuel cock assy , display assembly , assy front screen , glass left side quarter , glass right side , glass top , beading glass , beading glass top , fan cabin , glass upper door , horn , rock breaker moil bit
Tender For bid to ras supply of procurement of ied simulated range d d - desktop with software monitoring and controlling ieds with 55 inch 4k screen , rf network infrastructure , wireless transmitter or receiver unit with transponder for per ied , wireless transmitter or receiver unit with gps transponder for per person , single use device incendiary units , wireless ied identification and diffuser units device with a display to verify the mechanism and handling methods against each ied , battery li-ion 5200mah for wireless transmitter or receiver units , chargers , carry boxes , ied mechanisms different triggering , cctv system with nvr for monitoring the activation , preparation of control room , monitoring 55 inch screen , public address system , body cameras , display board of ied mechanism , warranty , amc
Tender For e-procurement of laboratory equipments and other items at coa, kumher (deeg) - food grain cleaner machine, three phase, dalia making machine, sieving machine (for size grading), roaster (40-180 deg.), storage bins and silos, pasta extruder machine, dryer (for semi-dried and dried pasta), pasta cutting and shaping tools, digital moisture analyzer, dough mixer (planetary mixer), proofing chamber, deck oven, bread slicer (31 pieces, 6 inch loaf length, electric), cake molds and baking trays 20 nos., pastry tools 10 nos., digital weighing m/c capacity - 250 gm, display type lcd, digital weighing m/c capacity - 30 kg platform size: 300*300 mm, cooling racks, packaging machine, dough sheeter, color analyzer, protein analyzer, double distillation unit, double beam spectrophotometer, ph meter, hot air oven, fat analyzer, texture analyzer, air conditioner (ac) 2 ton star rating, bod incubator (temperature range: 05 c to 70 c, display: digital lcd / led), desert cooler - (plastic body) 150 lit water tank capacity 3 side honeycomb pads, refrigerator ( energy efficiency-3-5 star, total capacity- 415 liter ), autoclave - (working pressure: 15 to 22 psi working temperature: 121 c to 132 c, pressure control device: piezostat, size/capacity (liter ): 70), laminar flow - (velocity 90 fpm 20% hepa filter 99.999 % efficiency for particles >0.3 m cabinet laminated high quality wooden board /pcrc sheet powder coated/stainless steel ss 304 (optional 316 grade) work table 304 stainless steel (optional 316 grade) airflow speed control speed controller (three step speed controller), steel racks (20-gauge c.r. sheet), digital weight balance (0-50 kg), bag closer machine, iron rack, spade, bucket, sieve, refrigerator 300 ltr, automatic digestion & distillation unit for protein estimation, automatic seed/grain counter, trinocular microscope with photography attachment with computer, stereo binocular microscope, water bath, electronic weighing machine, seed displayer (4 cavity), seed displayer (12 cavity), artificial vagina set, california mastitis test kit (cmt) including paddle-500 ml, poultry drinker, poultry feeder, display models of cattles (sahiwal & gir), display models of buffalos (murrah & surti), display models of goats (jamunapari & sirohi), display model of sheep (merino), display model of poultry (kadaknath & white leg horn), lab display model of reproductive system of cattle (male & female), lab display model of digestive system of cattle, chargeable battery-operated hedge trimmer, chargeable battery lawn mower, premium hedge shear, lopping shear, grafting and budding knife, secateur, saw, stain less khurpa, hoe, rake, fruit and vegetable dehydration machine, electronic weighing balance, pan balance, microscope, digital ph meter, deep freezer, poly pouch sealer, binocular microscope, insect collection box, insect collection big boxes for museum, insect killing bottle, insect collection nets (hand nets), bee keeping unit equipment s (unit), thermometer maximum, thermometer minimum, digital anemometer, robinsons cup anemometer, soil thermometer 5 cm, soil thermometer 10 cm, soil thermometer 15 cm, ordinary rain gauge, double stevenson s screen, soil heat flux plate, digital lux meter, solar pyranometer, thermograph, hygrograph, chlorophyll meter, meter scale, brix meter, diesel engine pump set 10hp with iron frame fitted and accessories as per technical specification, tractor pto operated water pump set and accessories as per technical specification, sprinkler irrigation system and laying of underground pipe line for supply of irrigation water and other items for an area of 9 ha as per technical specification (ha. area)
Tender For corrigendum : purchase of sports exercise physiology lab equipments - cardiopulmonary exercise testing system (including treadmill & cycle ergometer) (2 years warranty)(pac), portable telemetric metabolic analyzer for field and laboratory use.metabolic analyzer portable telemetric system for metabolic analysis should have the following specifications:designlatest generation, single body - weather and dust proof to suit our requirement of tough testing conditions. it should operate in standalone, holter and direct connection to pc modes.weight on subjectless than 1 kg including battery and ergonomically designed multi-size adjustable harnesstesting capabilitypulmonary gas exchange (vo2, vco2), vo2 max, sub-max vo2, thresholds (at, rcp), heartrate with hr belt, resting energy expenditure (ree, rmr), indirect calorimetry w/ face mask, substrates analysis (rq, %fat, %pro, %cho)analysis method breath by breathmotion sensorsinbuilt gps, altimeter, accelerometer (3d + 8g range), gyroscope (3d + 2000 o/s range) andmagnetometer/compass (3d + 1000 t range)wireless connectivitywireless data transmission: bluetooth 2.1 + edr class ii (range >900 meters line-of-sight)connectivityusb, audio, heart rate (aux), wireless device interface (bluetooth for integration with compatible optional peripherals like spo2, ecg etc.)data storagestorage: 512 mb flash > 2,000,000 breathsadditional: sd-hc card 32gb/fat32 - internal slot user accessibledisplay lcd: 3.5 lcd transflective colour - high visibility with led-backlit tfttouch-screen: resistive technology, that allows gloves and wet fingersanalysersoxygen: gfc 0-25% range, lifespan approximately 12 months (very easily user replaceable) response time 120 mscarbon-dioxide: digital ndir 0-10% range, response time 100 msbarometer: range -600 to +5500mflowmeter: bi-directional digital turbine ventilation range 0 to 300 l/min powerbattery: rechargeable li-ion smart battery w/ lcd charge status indicator. 2 packs backup battery: embedded to allow main battery replacement during testing without loss of datamain: 100-240v ac/dc adapter, for direct/main power supply and battery charging. essential accessories / consumablesthe system should be supplied with a compatible treadmill and ergo cycle as per specs below. list of standard items supplied and details of consumables including o2 sensor with their life span should be provided. a compatible laptop pc, colour deskjet printer, 3 litre calibration syringe & calibration gas mixture cylinder with regulator should be supplied with the systemquality assurancemust have european ce, us fda and iso certifications. treadmill running machine with user terminal (display & keyboard) stand- alone and remote control with cpet via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 300 kg (660 lbs) speed range: 0-25 km/h elevation: 0 to 28% reverse belt rotation motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v - belt, very quiet operation safety arch should be provided with harness of 5(five) different sizes (small to large) safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10 to +40 degrees c, humidity 30 to 70% display: touch screen display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs para control software for pc must have ce certificationergo cycle functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat adjustment easy to control and calibr
Tender For corrigendum : purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopa
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer- the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.warranty must be one year., electronic balance- the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. warranty must be one year., vaccum pump - the pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted withvacuum and filter cartridge., hot air oven- the inner chamber should be made of stainlesssteel and the outer chamber should be m.s powdercoated. the maximum capacity of the oven shouldbe 100 ml or more. the operational temperatureshould be between ambient to 250oc or more witha temperature accuracy of 1o c. pid based digitaltemperature control., double distillation unit- the unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil bath- the oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240oc (0.1oc increment) with a temperature stability of 1oc, water bath- the water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars., ph/ condutivity meter - operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range shouldbe in between 0.00 to 29.99 s/cm, uv cabinet- operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometer- application: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca 2+ :0-99.9 ppmli 2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required