Get complete information related to latest Glycolic Acid Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Glycolic Acid Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Glycolic Acid Tenders.
Tender For corrigendum : sch 6 laboratory chemicals, stains, reagents, etc. by tender - sch vi (supply of laboratory chemicals, stains & reagent solutions) - sch vi (supply of laboratory chemicals, stains & reagent solutions), hydrochloric acid l.r., salicylic sulphonic acid a.r., sulphuric acid a.r.assay 96-98%, mac conkey s agar with 0.15% bile salt, with crystal violet and nacl., nutrient agar - bacteriological grade, ammonium sulphate a.r., dextrose (anhydrous) a.r., diethyl ether a.r. 99% pure, formaldehyde 40% a. r. (1x 25 ltrs), isopropyl alcohol a.r. 99-100%, potassium iodide a.r. 99.8%, xylol (extra pure) a. r., elisa kits for hbs ag.(3rd generation kits)- one step sandwich elisa using monoclonal antibody & conjug-ate coated wells., hydrochloric acid commercial grade for cleaning purpose., vdrl antigen kits containing stabilised emulsions of cardiolipin lecithin & cholesterol adjusted to required sensitivity.the result should be observable under microscope., elisa kit for detection igm antibody to pathogenic leptospirosis shelf life to be one year atleast at the time of receipt of kit., ultra sensitive hbsag elisa screening test capable of detecting escape mutants., direct bilirubin kit method-jendrassik & grofs end- point method (diazotised sulphanilic acid)reagent type-liquid stable / lyophilized minimum reconstitution stability-on board : 3 days after mixing r1 & r2 linearity -10mg/dl (ce mark on kit), blood urea nitrogenmethod-initial rate uv-kinetic methodreagent type-liquid stable / lyophilized minimum reconstitution stability-45 days at 2 to 8 degreeslinearity - 250mg/dl (ce mark on kit), creatinine method-initial rate alkaline picrate method reagent type- 2reagent liquid stable / lyophilizedminimum reconstitution stability-liquid stable reagentslinearity -30mg/dl (ce mark on kit), vibrio cholerase polyvalent 01 antisera, vibro cholerae ogawa antisera, vibro cholerae inaba antisera, salmonella polyvalent antisera (a-g), salmonella group 02 antisera, salmonella group 04 antisera, salmonella group 09 antisera, colistin mic (e-test) strips, mupirocin (200mcg), antisera clostridium species, antisera e. coli o157, spore strips (bacillus steothermophilus spores for steam sterilization-10 spores), iodine crystals, rapid test for detection of hiv-1 & hiv-2 ab s and p24 antigen from serum , plasma and whole blood. specificity and sensitivity of the test should be 100% for all sample types sample volume should be lessthan 50ulno buffer addition should be required for testing of serum and plasma samples.test should be who prequalified, nitrate reduction kit, dubos broth (tween 80), phenopthalein disulphate tripotassium, yeast nitrogen base agar (twin pack), rapid detection of salmonella typhi igg/igm antibody test, rapid detection of dengue ns1 antigen & igg/igm antibody test in same card (rapid dengue duo test), rapid test to detect mpt 64 antigen of mycobacterium tuberculosis complex, the test principlecould be immunochromatography or agglutination, dengue-chikungunya rtpcr kit, potassium tellurite blood agar, rtpcr kit for detecting dengue virus, rtpcr kit for detecting influenza a, h1n1, h3n2 & influenza b virus, viral rna extraction kit - automated,magnetic bead based compatible with kingfisher flex & hi media, rapid test for crypto+giardia+entamoeba, albumin bovine serum (a. r. grade ), sterile microtitre assay plate 96 well with lid clear round bottom non treated polypropylene, f-18 fdg (to be delivered to nuclear medicine department due to short half life when ordered ), colistin microbroth dilution test (ready to use predrug-coated plates), hepatitis b virus e antigen elisa (hbeag), cefotaxime e strip (0.016- 256 mcg/ml), ceftazidime avibactum e strip (0.016- 256 mcg/ml), chloramphenicol e strip (0.016- 256 mcg/ml), class v chemical indicators strips for steam sterilizers., distilled water, hepatitis b core igm elisa, manual nucleic acid extraction kit (silica column based), meropenem
Tender For corrigendum : sch 9 surgical sutures by tender - sch ix (supply of surgical sutures), absorbable surgical gut (catgut) chromic size 1, 3/8 circle, 63mm needle, blunt tipped length at least 70cm. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), absorbable surgical gut (catgut) chromic size 4-0 with 1/2 circle, round body needle in sterile foil pack, length atleast 70cm. range 12-16 mm. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), absorbable surgical gut (catgut) chromic size 4-0 with 3/8 circle, reverse cutting needle in sterile foil pack, needle size 12-16mm. length at least 76 cm. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), absorbable surgical gut (catgut) chromic size 4-0 with 3/8 circle cutting needle in sterile foil pack 16mm x 76cm. length at least 76 cm. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), absorbable synthetic suture a coated, braided, synthetic, absorbable suture material having absorption time range of 60-90 days. the suture material should be a glycolide/lactide co-polymer derived from glycolicacid & lactic acid.it must have a coating of glycolide/lactide/co-polymer & calcium stearate or calcium stearoyl lactylate or equivalent. size 1-0 with needle in sterile foil pack 40 mm taper point 3/8 circle or 1/2 circle reverse cutting heavy 90 cms. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), absorbable synthetic suture a coated, braided, synthetic, absorbable suture material having absorption time range of 60-90 days. the suture material should be a polyglyconate / glycolide/lactide co-polymer derived from glycolicacid & lactic acid.it must have a coating of glycolide/lactide/co-polymer & calcium stearate or calcium stearoyl lactylate or equivalent. size 4-0 with needle in 20mm, 3/8 circle reverse cutting, length 70cm, undyed. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), absorbable synthetic suture a coated, braided, synthetic, absorbable suture material having absorption time range of 60-90 days. the suture material should be a polyglyconate / glycolide/lactide co-polymer derived from glycolicacid & lactic acid.it must have a coating of glycolide/lactide/co-polymer & calcium stearate or calcium stearoyl lactylate or equivalent. size 5-0 with needle 12-16mm in 45cms 3/8 circle reverse cutting undyed. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), monofilament absorbable synthetic suture poly-diaxanone or polyglyconate size 5-0 with cutting / reverse cutting needle size 16mm in 45cms 3/8 circle. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), absorbable synthetic suture a coated, braided, synthetic, absorbable suture material having absorption time range of 60-90 days. the suture material should be a glycolide/lactide co-polymer derived from glycolicacid & lactic acid.it must have a coating of glycolide/lactide/co-polymer & calcium stearate or calcium stearoyl lactylate or equivalent size 6-0, 3/8 circle, 8mm double arm micropoint spatulated length 45cm. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), linen thread on spools size 20, linen thread on spools size 30, linen thread on spools size 40, linen thread on spools size 60, linen thread on spools size 80, linen thread on spools size 100, polyamide monofilament 8-0 on round body needle 6mm. length 35-40 cm. (*rate to be quoted per box containing 12 foils. *supply can be made with minimum of 12 foils per box.), polyamide monofilament 9-0, 6mm needle 3/8 circle round body micro point length 35-40 cm. (*rate to b