Web Analytics Made Easy - StatCounter

Granite Tile Repair Tenders

Get complete information related to latest Granite Tile Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Granite Tile Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Granite Tile Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43111326 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim

corporations/Associations/Others

CTN :43136003 Due date: 23 Dec, 202523 Dec, 2025 2.53 Lacs
Tender For installation of new distribution panel and cable laying at first floor of office of the executive engineer building under road roller department.

State Government

CTN :43111734 Due date: 17 Dec, 202517 Dec, 2025 NA
Tender For providing and laying vitrified floor tiles, repairing, painting work, 1st floor lab- s- 41, computer lab & installation of wash basin near dean of science office at department of physics, university of lucknow.

State Government

CTN :43111735 Due date: 17 Dec, 202517 Dec, 2025 NA
Tender For providing and laying vitrified floor tiles, laboratory sink, granite stone & painting work at lab no- s- 188 department of botany, university of lucknow

Central Government/Public Sector

CTN :43114287 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For supply of supply of stand mounted fabricated prefabricated sub main distribution board smdb , itc and labelling of floor mounted pre fabricated , supply of surface recess , itc of pre fabricated 3 phase 415v 6 way tp surface , supply of pre fabricated 240 v rated 6 way , itc of pre fabricated 240 v rate 6 way sp , supply of 4 pole 160a manual changeover switch disconnector , itc of 4 pole 160a manual changeover switch disconnector with terminal shrouds , laying of pvc insulated and pvc sheathed xlpe , laying of pvc insulated and pvc sheathed xlpe power cable , laying of one number pvc insulated and pvc sheathed xlpe , supply of 4c x 10 sq mm stranded copper conductor , laying of 4c x 10 sq mm stranded copper conductor , supply of indoor end termination , making indoor end termination , supplying 300 mm width x 50 mm depth x 1 6 mm , installing 300 mm width x 50 mm depth x 1 6 mm , supplying 100 mm width x 50 mm depth x 1 6 mm , installing 100 mm width x 50 mm depth x 1 6 mm , supplying 25 mm x 6 mm g i strip , laying 25 mm x 6 mm g i strip , supply of 6 swg dia g i wire , fixing 6 swg dia g i wire , supply of maintenance free earth kit , itc of maintenance free earth kit , supply of frls pvc insulated stranded copper conductor , drawing of frls pvc insulated stranded copper conductor , supply of 20mm size of isi marked hgms ms black painted conduit , installation of 20mm size of isi marked hgms ms black painted conduit , supply of 25mm size of isi marked hgms ms black painted conduit , installation of 25mm size of isi marked hgms ms black painted conduit , supplying 1 or 2 module 75mmx75mm size gi box with modular base , fixing 1 or 2 module 75mmx75mm size gi box , supplying 4 module 125mmx75mm size gi box , fixing 4 module 125mmx75mm size gi box , supplying 6 module ) /bid number: gem/2025/b/6962998 * /dated: 09-12-2025 & & / bid document1 / 49 & & ' ' /item category200mmx75mm size gi box , fixing 6 module 200mmx75mm size gi box , supplying 8 module 125mmx125mm size gi box , fixing 8 module 125mmx125mm size gi box , supplying 5 6 amps modular switch , fixing 5 6 amps modular switch , supplying 3 pin 5 6 amp modular socket outlet , fixing 3 pin 5 6 amp modular socket outlet , supplying 15 16 a modular switch , fixing 15 16 a modular switch , supplying 6 pin 15 16 a modular socket , fixing 6 pin 15 16 a modular socket outlet , supplying 3 pin 5 a ceiling rose , fixing 3 pin 5 a ceiling rose , supply of 1 phase 230v 35w or better batten type , installation of 1 phase 230v 35w or better batten , itc of ceiling fan , supply of 300 mm sweep heavy duty size exhaust fan , itc of 300 mm sweep , supplying 20 a 240 v spn industrial type socket outlet , fixing 20 a 240 v spn industrial type socket outlet , supply of 2cx1 5mm2 copper extruded pvc inner sheath armoured , laying of 2cx1 5mm2 copper extruded pvc inner sheath armoured , supply of addressable photo thermal multi sensor smoke detector ivory , itc of addressable photo thermal multi sensor smoke detector ivory , supply of addressable flex manual call point , itc of addressable flex manual call point , supply of addressable intelligent wall mounted sounder strobe , itc of addressable intelligent wall mounted sounder strobe , supply of junction box with elmex type terminal block , installation of junction box at ceiling wall surface recess , integration of the fire detectors mcp sounders , dismantling of one 01 no existing floor mounted electrical panels , dismantling of cables of size upto 150 sq mm , dismantling of incoming cables of size 16 35 sq mm , dismantling and removing of existing switchboard industrial sockets , dismantling of existing g i strip upto size of 25mm x 6mm , dismantling of existing conduits sizes 20mm 25mm 32 mm , dismantling of existing fire detector mcp sounder fire panel

CTN :42998990 Due date: 30 Dec, 202530 Dec, 2025 1.07 Crore
Tender For akankshi nagar yojanantargat nagar panchayat payagpur men block parisar ke andar khali bhoomi par adhyayan kendra ki sthapna hetu library ka nirman karya. - earth work in excavation by mechanical means (hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kinds of soil. as per dsr no.-2.8.1, filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m as per dsr no.-2.25, providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) as per dsr no.-4.1.8, supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. as per dsr no.-2.27, treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 coarse sand) to match the existing floor: with chlorpyriphos/lindane e.c. 20% with 1% concentration. as per dsr no.-2.35.3.1, reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). as per dsr no.-5.2.2, reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). as per dsr no.-5.3, ground floor, first floor, as per dsr no.-5.3b, as per dsr no.-5.3b, providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). as per dsr no.-5.1.2, centering and shuttering including strutting, propping etc. and removal of form for. as per dsr no.-5.9, foundations, footings, bases of columns, etc. for mass concrete. as per dsr no.-5.9.1, lintels, beams, plinth beams, girders, bressumers and cantilevers. as per dsr no.-5.9.5, columns, pillars, piers, abutments, posts and struts. as per dsr no.-5.9.6, brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in. as per dsr no.-6.1.1 & 6.1.2, cement mortar 1:4 (1 cement : 4 coarse sand), cement mortar 1:6 (1 cement : 6 coarse sand), cement mortar 1:6 (1 cement : 6 coarse sand), cement mortar 1:6 (1 cement : 6 coarse sand), providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) as per dsr no.-4.10, providing & applying a coat of residual petroleum bitumen of grade of vg-10 of approved

State Government

CTN :41162488 Due date: 12 Dec, 202512 Dec, 2025 NA
Tender For bid to ras corrigendum : supply of networking active and passive components with installation c c - managed layer 3 10 gig 48 ports with 4x40g slash 100g uplink ports 2x hot swappable load sharing power supplies , managed layer 3, 24 port 1 slash 10g sfp plus ports, 4x 100g uplinks ports , managed layer 2 24x1g copper ports with 4 x 10g sfp plus ports , 10g multimode transceiver , 10g singlemode transceiver , 1g copper transceiver , 6 core multimode optical fiber cable , 96 fiber rack mount liu loaded with lc adapter and lc pigtails multimode , 6 fiber rack mount liu loaded with lc adapter and lc pigtails multimode , lc-lc multimode fiber patch cord - 3 meter , 6 core singlemode os2 optical fiber cable , 48 fiber rack mount liu loaded with lc adapter and lc pigtails singlemode , 6 fiber rack mount liu loaded with lc adapter and lc pigtails singlemode , lc-lc singlemode fiber patch cord - 3 meter , cat6 utp cable 305 meter box , cat6 24 port patch panel - unloaded , cat6 information outlet - jack for patch panel , cat6 information outlet - jack for end user , face plate , surface mount box , cat 6 utp patch cord - 1 meter , cat 6 utp patch cord - 3 meter , 42u floor standing rack 800 x 1000 mm with accessories , 15u wall mount rack 600mm depth with accessories , plb hdpe pipe 40 x 33mm , 1.5inch pvc conduit isi - lms , laying of pvc conduit 1.5inch , laying of fiber , laying of hdpe pipe 40 x 33mm , treanchless digging though hdd machine , splicing of pigtail , fixing and termination of patch panel cat6 , fixing of rack , laying of utp cable , termination of i slash o , termination of patch panel , penta scanning of utp nodes , otdr of fiber, per core , installation and configuration of switches , 3 years camc of active components and modules ) /bid number : gem/2025/b/6469342 * /dated: 22-07-2025 & & / bid document 1 / 33

State Government

CTN :43111585 Due date: 15 Dec, 202515 Dec, 2025 19.60 Lacs
Tender For providing and laying floor tile in rooms and hall in commerce block) deposit work

State Government

CTN :42561196 Due date: 11 Dec, 202511 Dec, 2025 1.23 Lacs
Tender For corrigendum : laying cement concrete paver blocks in parking floor and near dormatry of rest house at rabs hps barginagar

Central Government/Public Sector

CTN :42945833 Due date: 29 Dec, 202529 Dec, 2025 NA
Tender For corrigendum : earthwork in formation, blanketing, trolley refuges and construction of various bridges (including miscellaneousellaneous works like pitching, toe wall, floor protection), construction of passengers platforms & circulating area, construction of lc gate lodges, lc roads, residual/balance works of robs, dismantling of robs, laying and linking of broad gauge main line, loops lines including points and crossings, tamping of track, destressing of lwrs, transportation of p.way material, supply and stacking of stone ballast and other miscellaneousellaneous& incidental works required for successful completion of work from chirai (including) to gandhidham (including) in connection with quadrupling of samakhiyali - gandhidham section of ahmedabad division on western railway.
 Loading, Please wait...

Connect us via What's Up