Tender For corrigendum : supply of driver display unit as per spec. no. clw/es/3/0487 alt.c, along with recording facility of 43p arameters of 3 phase locomotives and incorporating healthiness/isolation of each motor, rectifier and invert er module in gui (graphicaluserinterface) of home screen of ddu (driver display unit). [ warranty peri od: 30 months after the date of delivery ]
Tender For re e tender notice nit no 16 for purchase and installation of mdr analysis software and analysis station for icmr project under mru of nil ratan sircar medical college kolkata 14
Tender For re e tender notice nit no 16 for purchase and installation of mdr analysis software and analysis station for icmr project under mru of nil ratan sircar medical college kolkata 14
Tender For corrigendum : nfov module - mwir camera module, infrared (ir) detector, infrared (ir) optics module, video processing electronics card, power supply and communication controller electronics card, emi/ emc filter card, rugged mechanical housing for nfov sensor module, hd-sdi display (with two hd-sdi video inputs), graphicaluserinterface (gui), device drivers, software complete code (on dvd/ pen drive), field testing and integration equipment, complete vhdl code or processor code of video processing software module for customized video processing electronics card, mwir detector, variable dc power supply (18-36vdc, 30 a), hdsdi to ethernet converter full hd resolution upto 60 hz. (support for windows 10), hdsdi to usb recorder (support for windows 10), 02 channel hdsdi to fiber optics transceiver units with foc (200m), programming dongles interfaces for updating codes in processor / micro controllers etc., interconnecting connectors, cables and harnesses for all electrical interfaces. (internal and external), rugged carrying case, lens covers and protective covers, temperature controller system (hot and cold), test jig, fixtures, installation tool kits and mounting hardware., swir camera module, infrared (ir) detector, infrared (ir) optics module, emi/ emc filter card, proximity electronics, power module, interface card, rugged mechanical housing for nfov sensor module, hd-sdi display (with two hd-sdi video inputs), graphicaluserinterface (gui) software complete code (on dvd/ pen drive), field testing and integration equipment, complete vhdl code or processor code of video processing software module for customized video processing electronics card, swir detector, solidworks premium 2024 or higher (with simulation) node locked perpetual licensed software, version upgradable for minimum 3 years, for mechanical modeling & simulation, vivado xilinx enterprise software with perpetual license (latest version), rugged mechanical cabinet (shelf type) for clean storage of electro-optical instruments, test jig, fixtures, installation tool kits and mounting hardware., interconnecting connectors, cables and harnesses for all electrical interfaces. (internal and external), cables and connectors (assorted) with each nfov sensor module, application code / usergraphicalinterfaces (for swir and mwir): 1 set in dvd (graphicaluserinterface for camera control implementing control for all camera functionality interface to camera via rs422/232, focus, zoom, polarity, agc, int time etc, nuc calibration, matlab application for image quality assessment), documentation charges (as per specifications), nre charges (if applicable)
Tender For corrigendum : purchase of biomechanical lab - force platedimensions (w x d x h) in mm : 600 x 400 x up to 50 number of axes for force measurement: all 3 axes. x,y,z plate should be portable in naturesensor type: piezoelectricsampling frequency-(hz) =1000 hz or more force measured on each axis-fx,fy: 2,000 newton or more, fz: 10,000 newton or more hysteresis- (%fso): 0.5 linearity (%fso) 0.5 crosstalk (%) : 2water resistance rating: ip 50 or better.should be inclusive of installation.should be supplied with carrying case for 2 plates and noise free ups for on-ground assessment. the carrying case should be strong and sturdy.should be able to accommodate portable force plate 9286 ba, daq box 5695 and connecting cablesshould be able to protect the equipment from rain, impact and dust, should have rollers to move easilyshould be able to accommodate an ups also., isokinetic dynamometershould be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric ,eccentric, concentric ,and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees.should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda, nord boardit should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless conne
Tender For request for proposal (rfp) for analysis, design, development, and deployment of a web based medical claims software and mobile application with a 5-year on-site maintenance contract
Tender For providing of custom bid for services - daily collection and disposal of bio medical waste from 60 bedded divisional railway hospital ambala cantt for 2 years as per sow attached,custom bid for services - barcoding charges including the android app and mobile based scanning software for divisional railway hospital ambala cantt ,,custom bid for services - item rate for per piece bio hazard bar code labels red yellow white blue for divisional railway hospital ambala cantt for two years as per sow attached