Tender For erection of total 12 nos. 132 kv las along with earth pits for 132 kv tbvara- vontihadi feeder, 132 kv tbvara- garividi feeder, 132 kv tbvara- goldstar feeder, 132 kv tbvara- kothavalasa feeder at 132kv tb vara ss under rmi 24 25
Tender For supply of power contactor for feeder - 1 & feeder- 2 and bus coupler, 3 pole, 1000v ac, 50 hz, suitable for 500kva, 750v ac on load switching under ac-6a category at temperature of 70 degree celsius & coil voltage of 110v+25% -30% dc with surge suppressor, aux. contacts 2no+2nc as per rdso specification no. rdso/pe/spec/tl/0195-2019 (rev.0) suitable for switch board cabinet for hog compliant lslrd coaches.( as per attached specification) [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of parallel clamp for 193 sq.mm. contact wire to 129 sq.mm. catenary or 105 sq.mm. jumper or 150 sq.mm. feeder wire as per c.rly.elect/trd drg. no.fm/dc-ac/15. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]
Tender For nit 21 work of replacement of submersible pump sets and accessories of tubewell at various locations under uwss chomu under jen section chomu (urban) under sub div chomu in jurisdiction of executive engineer, phed district division ii, jaipur - 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.2 up to 5.5 kw (7.5 hp) & head above 120 mtr., 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.4 7.5 kw (10 hp) & head above 120 mtr., 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.6 9.3 kw (12.5 hp) & head above 120 mtr., 2.18 supply and fixing of electric control feeder panel comprising of suitable rating mccb , fully automatic star-delta starter, over load relay, ampere meter with cts, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. the panel should have space for energy meter ( supplied by discom). all these equipments shall be housed by panel box made out from 18 gauge m.s. sheet with powder coating. panel should be of minimum size 900 x 600 x 450 mm with stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18 and double door including in built locking system. the legs should be embedded in m-15 cement concrete plat form. the size of cc platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. the panel should have opening of suitable size in front of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt ac supply.2.18.1 above 5 hp and up to 10 hp, 2.18 supply and fixing of electric control feeder panel comprising of suitable rating mccb , fully automatic star-delta starter, over load relay, ampere meter with cts, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. the panel should have space for energy meter ( supplied by discom). all these equipments shall be housed by panel box made out from 18 gauge m.s. sheet with powder coating. panel should be of minimum size 900 x 600 x 450 mm with stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18 and double door including in built locking system. the legs should be embedded in m-15 cement concrete plat form. t
Tender For feeder selection rotary switch with marking "i-0-ii" net1-local main supply-net2(change over switch with 0-position 3-pole) rated voltage 690v ac rated current 16a confirming to rdso specificationrdso/pe/spec/ac/0185-2015 rev. 0 or latest, as per bom siemens catalouge no. 3sb5000-2db01+3sb5400-0a accepted make siemens, teknic, ge, salzer, kaycee [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of materials for commissioning of roots blower system with rotary feeder at unit#3, esp of gsecl-wtps. - 1" pulse valve of fly ash system, unit -7 , sequential timer for pulse jet sys, 10 channels
Tender For kkedc 1)eos to 1no addl st.light of 8 loc in railway to brandy shop road to the commissioner, nagercoil corporation under pvm section. 2)eos to 1no addl st.light of 9 loc the commissioner, nagercoil corporation at kamarajar nagar roadunder pvm section. 3)improvement estimate is proposed for the provision of an additional lt overhead line to the existing fii feeder at rajeev gandhi ss strengthening the existing 7/2.11 and 7/2.59 acsr conductores to 7/3.15 aaac conductor and insertion of 8mtr psc poles under parvathipuram section. 4)improvement estimate for 3nos 9 mtr insertion pole at loc fii/48, fi/5a and 6a and 9nos 8mtr insertion pole at fii/49a, 44a, 45a, fi/46a and 47a pandarathoppu ss 100 kva in kaliyankadu feeder 110/33-11 kv nagercoil ss under parvathipuram section. 5)replacement of deteriorated rcc pole 9mtr at loc fi/8,9 sarathanagar ss, 1no 9mtr inserting pole at loc a in ganganager and pandarathoppu ss under parvathipuram section.. in kanyakumari edc.
Tender For provn of step down transformer for dedicated electric supply from apdcl feeder alongwith allied work services for 5 afsb under ge (af) borjhar.