Get complete information related to latest Gravity Mains Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gravity Mains Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gravity Mains Tenders.
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds.
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds. , 2coat paint bcw,clr,bfp,cep,drip pump and line , 2coat paint cst,bcw pump ,swc tank,line,valve , 2coat paint hcplg,sw,bcw,cw exc clr line , 2coat paint air washer sys,cep or phos orhyd , 2coat spray paint syn super enamel lpc , 2coat spray paint front ped,barring gear , 2coat spray paint brg and housing turbine , 2coat spray paint cntl valve casing , 2coat spray paint condenser and line , 2coat spray paint main oil tank , 2coat spray paint main ejector , 2coat spray paint centrifuging machine , 2coat spray paint lube oil cooler , letter writing 2 inch size dia
Tender For restoration of rain damages of wss alsu kangoo dehar in tehsil sundernagar distt. mandi h.p. (sh:-restoration of various gravitymains and sub-main lines)
Tender For laying of roof slab and raising of rcc side walls for air valve, scour valve, butterfly valve and anti vacuum valve chambers in place of existing damaged roof slabs, and also raising of rcc sidewalls for the valve chambers due to widening and laying of new road work by the rand b department on 2200/2375mm dia ms pumping and gravitymains of kdwsp phase-i, ii and iiii from kodandapur to sahebnagar under sd-i of trans.div.iii, sahebnagar
Tender For construction of pressurized pipe distribution network lift irrigation scheme to supply water for irrigation to deliver at farmers field up to 1 ha with a duty of 0.70 lit/sec/ha and maintained up to 4 ha chak, keeping the discharge of minimum 3 times the duty at one hectare and at least 20 meter residual head at 1 ha for pressurized irrigation by rotation in village kapua, block -patharia ,dist. -mungeli in 160 ha. in kharif (right side of khairi anicut as indicated in index map), out of total gross command area 270 hectare fully covering the entire compact, contiguous possible arable area beyond 500m from submergence line (ftl line) of khairi anicut as indicated in the index map for irrigation system without exceeding total power requirement for solar pumps with solar panel of 100 kwp.it includes all activities starting from survey, investigation, designing, estimating costing, procurement, construction, laying, installing, energizing, etc. of pumping system, rising and gravitymains, main line, branch lines, distribution network, controlling and regulation system , scada work with automation etc. for supply of filtered water for irrigation under pressure. the work also includes construction of chowkidar quarter, pump house, installation of solar power plant and sub station with transformer of required capacity by liasoning with cseb, management, operation and maintenance (mom) and defect liability (dl) for the period of 05 years after completion and mom and dl period run simultaneously and work also including foundation stone laying ceremony and inauguration ceremony and as directed by engineer-in-charge as per details given in scope of work
Tender For construction of pressurized pipe distribution network lift irrigation scheme to supply water for irrigation to deliver at farmers field up to 1 ha with a duty of 0.70 lit/sec/ha and maintained up to 4 ha chak, keeping the discharge of minimum 3 times the duty at one hectare and at least 20 meter residual head at 1 ha for pressurized irrigation by rotation in village bandhapali, baghanpur, bundeli , baragaon and barpali block sarangarh ,dist. sarangarah-bilaigarh in 150 ha. in kharif (madhavpali anicut as indicated in index map), out of total gross command area 270 hectare fully covering the entire compact, contiguous possible arable area beyond 500m from submergence line (ftl line) of madhavpali anicut of dist- sarangarah-bilaigarh as indicated in the index map for irrigation system without exceeding total power requirement for solar pumps with solar panel of 110 kwp.it includes all activities starting from survey, investigation, designing, estimating costing, procurement, construction, laying, installing, energizing, etc. of pumping system, rising and gravitymains, main line, branch lines, distribution network, controlling and regulation system , scada work with automation etc. for supply of filtered water for irrigation under pressure. the work also includes construction of chowkidar quarter, pump house, installation of solar power plant and sub-station with transformer of required capacity by liasoning with cseb, management, operation and maintenance (mom) and defect liability (dl) for the period of 05 years after completion and mom and dl period run simultaneously and work also including foundation stone laying ceremony and inauguration ceremony and as directed by engineer-in-charge as per details given in scope of work.
Tender For corrigendum : supply of rpl no 10 c c - suppl and fixing of 1 exhaust fan for kitchen room with 15amp socket , supply and fixing of electric wiring in chamber no 02 , supply and fixing of 06 15amp combination board , supply and fixing of 05 led bulb 9 watt , supply and fixing of 01 switch board 10inch x 12inch , supply and fixing of 10 switch 5amp , supply and fixing of 06 socket 5 amp , supply and fixing of 02 security light , replacement of existing 02 ms icon pipe bend of toilet outlet of master cabin toilet of sbs as per existing specification , repair of sea water pipe line of 2hp motor , replacement of existing tapet cover gas kit of main engine of both sides as per existing specification , repair of radiator fan vibrating defect of sbs of main engine , replacement of existing 02 iron battery box as per existing specification including all changes , supply and fixing of 02 exhaust fan of aux engine room , repair of leakage defect of pt pump of sbs and replacement of existing fuel line as per exiting specification