Web Analytics Made Easy - StatCounter

Guide Vanes Tenders

Get complete information related to latest Guide Vanes Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Guide Vanes Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Guide Vanes Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45474888 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For corrigendum : gas turbine generator bearings rebabiting work at ntpc faridabad

Central Government/Public Sector

CTN :45719548 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For procurement of spares for gas turbine model 13d2 for upcoming c inspections at ntpc anta - shim stator,bst495439p0001,ge vernova, seal bush inner,bst495386p0001, cup spring,bst495442p0001,ge vernova, shim stator,bst575058p0001,ge vernova, seal bush,gmd5448017p0001,ge vernova, spring package,gmd5448018p0001, sealing strip,gmd5349000p0010,ge vernova, pressure regulator,r408690p0048, caulking wire,gmd0318067p0002,ge vernova, sight glass assy,gmd0886079r0002,ge

Central Government/Public Sector

CTN :45733590 Due date: 10 Jul, 202610 Jul, 2026 88.06 Lacs
Tender For repair of 12 mw gas expansion turbine rotor.

State Government

CTN :43656606 Due date: 23 Jul, 202623 Jul, 2026 3.44 Crore
Tender For corrigendum : implementation automatic generation control on 4 gas turbine generators of 1500 mw pps iii bawana

Central Government And Public Sector

CTN :45730207 Due date: 22 Jul, 202622 Jul, 2026 NA
Tender For supply of flowmwter of kromschroder make with model no dm 400 z100 40 or exactly equivalent in other makes krom schroder/madas/honeywell/maxon and eclipse with the following specifications nominal flow rate (qn): 400 cubic meter/h, measuring range: -32 - 650 cubic meter/h, display: mechanical counter with optional pulse output, maximum operating pressure (pu max): 4 bar (gas and air), pulse generator: e1 and e200 compatible for integration with monitoring/control systems, meter type: turbine/mechanical flow meter (dm series) with paddle or rotor mechanism that drives index display, dn (nominal size) 100 flange or intermediate connection size connection size 100 standard nominal connection (z100 indicates pipe 100 mm) length - 150 mm body length between connection faces height to top of counter - 165 mm vertical dimension to instrument/mechanical index body height - 80 mm height of the main body excluding index. weight: approx. 10 kg note: (1) tenderer shall quote along wiyh the technical/dimensional catalogue and adc. (2) only oem/authorised dealers of oem shall participate in the tender. [ warranty period: 18 months after the date of delivery ] ]

CTN :45700275 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For gt module support system-fuel filtering module gt module support system-hydraulic starting module gas turbine

CTN :45701957 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For gt module support system fuel filtering module gas turbine

CTN :45233864 Due date: 29 Jul, 202629 Jul, 2026 NA
Tender For corrigendum : supply of spares lm 2500gt module support system – fuel fitering module gas turbine - metal o-ring, gasket, nut, wt, wt, wt, gasket, o-ring, sensor, sensor,cit/cip, gasket, hydraulic filter (6 inch filter housing), 3/4" flexible hose, hose assys: manifold port to tank, hose assys: pump a to instrument panel, hose assys: pump b to instrument panel, pin, gasket, bolt, set, container, htr bld 1 - metal o-ring, gasket, nut, wt, wt, wt, gasket, o-ring, sensor, sensor,cit/cip, gasket, hydraulic filter (6 inch filter housing), 3/4" flexible hose, hose assys: manifold port to tank, hose assys: pump a to instrument panel, hose assys: pump b to instrument panel, pin, gasket, bolt, set, container, htr bld 1

CTN :45233865 Due date: 29 Jul, 202629 Jul, 2026 NA
Tender For corrigendum : supply of lm 2500 module support system-fuel filtering module , gas turbine - coalescer cartridge ca33-3, separator cartridge st629fd, duplex pre-filter- filtering cartridge mp5, brg, plc, filter element, charge pump, spin-on, packing, blade stg 11 wide platform, detector, vsvi, vai-48, vao-8, vdop-24, vlli-24, hose assys: supply pump to filter a & b, filtering basket, actuation hose, 1/4" id x 30"l, process valve & instrument - 1/2" hose assy, process valve & instrument - 3/4" hose assy, power filter, emi, 20a, 50vdc, circuit breaker, 20a 2 poles, vdmc/vme pentium sbc+one pmc card tab 08 (ps322875085268), 5a relay, ecu power supply, rugged panel mount 2in trackball, network interface switch, gasket, instrumentations (pumping skid) - pressure gauge 0 10 bar, loosen components - flow meter prosonic 92f50, instrumentations (filtering skid) - magnetic level indicator

corporations/Associations/Others

CTN :45345524 Due date: 06 Jul, 202606 Jul, 2026 10.97 Lacs
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds.
 Loading, Please wait...

Connect us via What's Up