Tender For tender for supply of computer hardware and networking systems - server primary and secondary (dell/hp/equivalent) , san storage (dell/hp/equivalent) , nas (long terms storage) (dell/hp/asustor/equivalent) , kvm switch , 24 port l3 switch with 4 sfp port , rack for above servers and storages , storage (dell/hp/asustor/equivalent) , dr server (dell/hp/equivalent) , 16u rack - 12 port 1 no. , network switches - 24 port with 4 sfp port , radiology work station cpu (dell/hp/equivalent) , 8 mp medical grade monitor - diagnostics , 8 mp medical grade monitor - clinical , viewing station cpu (dell/hp/equivalent) , tablet wifi only , voice recognition software and mike , voice recognition software server hardware , antivirus , 10 kva ups with 30 minutes backup for all server and storage for dc and dr , 600va ups for all the work stations , air conditions for dc and dr room , cd dvd publisher (100 disc capacity)
Tender For supply of rf analyzer or spectrum analyzer , sdr system complete usrp b210 and antennas and lna filter kit , rf signal generator , digital storage oscilloscope , logic analyzer , benchtop inductance capacitance resistance meter , smd rework station , esd work benches , precision esd toolkit and microscope , rf cables and adapters kit , vna calibration kit , high end desktop workstation for diagnostics mil grade , c two software , rf shielded enclosure faraday cage , bench power supply , building earth and earthing pit , centralised ups online system , mil grade electrical works , fire and smoke alarm system , rf safety devices , annual calibration year one
Tender For rate contract of supplement medicine and diagnostic - description of supplement medicine & diagnostics, albendazole tablet 400 mg, calcium tablet (500 mg elemental + vit d3 250 iu), ifa red: prophylactic (preventative) dose: typically one tablet daily (containing 60-100 mg elemental iron and 400-500 g folic acid), usually starting after the first 12 weeks of pregnancy and continuing for a minimum of 180 days.therapeutic dose: if you are diagnosed with anemia, your doctor may increase the dosage to two tablets daily.postpartum: it is often recommended to continue taking these supplements for at least three months after childbirth., digital hemoglobinometer: measurement range: typically 0 - 25.6 g/dl (or 0 - 256 g/l).methodology: reflectance photometry or absorbance spectrophotometry.sample type: capillary, venous, or arterial whole blood.sample volume: very small, usually between 8 l and 15 l.time to results: under 15 - 60 seconds.memory capacity: stores 500 to 1,000 test results with date, time, and patient id.power: rechargeable battery or aa batteries., digital hemoglobinometer strips: sample type: fresh capillary whole blood (finger prick) or venous whole blood.blood volume: 10 l to 30 l (approximately one drop).measuring range: usually 3.0 to 25.6 g/dl.result time: between 15 to 60 seconds, depending on the testing mechanism.operating temperature: stable between 2 c to 40 c.shelf life: typically 18 to 24 months from the date of manufacture when stored properly. digital hemoglobinometer will be free as per company policy., glucometer: measurement range: typically 10 mg/dl to 600 mg/dl (or 0.6 mmol/l to 33.3 mmol/l). results falling above or below this range are generally flagged as "high" or "low".testing method: usually employs electrochemical biosensors (like glucose oxidase or glucose dehydrogenase) to generate a detectable electrical current from the blood sample.accuracy standards: devices generally conform to en iso 15197:2015 performance criteria, which require 95% of results to fall within 15 mg/dl of lab values at concentrations 100 mg/dl, and within 15% at concentrations 100 mg/dl.hematocrit range: most meters accommodate blood hematocrit levels between 10% and 65%.power source: usually powered by 1 to 2 standard coin-cell batteries (e.g., cr2032).physical specs: lightweight and compact, typically weighing between 40g and 75g., glucometer strips: blood sample volume\(0.3\text{ \mu l}\) to \(1.0\text{ \mu l}\) (capillary blood)measurement time5 secondsmeasurement range10 mg/dl to 600 mg/dl (varies slightly by meter)enzyme technologyglucose oxidase (god) or glucose dehydrogenase (gdh)shelf life12 to 24 months (usually 3 to 6 months after opening)operating conditions4 c to 30 c (storage), 10-90% relative humidity. glucometer will be free as per company policy., ors: recommended by the world health organization (who) and unicef- sodium chloride (nacl): 2.6 gglucose (anhydrous): 13.5 gpotassium chloride (kcl): 1.5 gtrisodium citrate dihydrate: 2.9 gtotal weight: 20.5 g