Tender For rate contract of supply of aluminium- copper winding wires - strips of sizes and other allied material -t andp items required for repair of damaged distribution transformers of various capacities at electric central workshop division, pampore, kmr
Tender For tender of workshop material - white bit, carbide tip, h.s.s. power hacksaw blade, ss drill bits, ts drill bits, grinding wheel , tap set bsw, tap set bsp, drill chuck, boiler tube expander, thread gauge etc...
Tender For annual fixing of rates for supply of workshop material as per rec/is/pdd approved standard and rec drawings, in the jurisdiction of electric division(jpdcl) poonch for the financial year 2026-27 (all the items should be as per latest specifications and drawing adopted/approved by department) - items, se. aluminum winding wire (round) in sizes 12 to 21 swg, dpc aluminum winding wire (round) in sizes from 12 to 21 swg., dpc aluminum strip of sizes for lv winding of distribution transformers 25kva to 250kva, se. aluminum winding wire (round) in sizes 12 to 21 swg.( in exchange of one kg of scrap including insulation coverage ie salvaged conductor), dpc aluminum winding wire (round) in sizes from 12 to 20 swg.(in exchange of one kg of scrap including insulation coverage ie salvaged conductor), dpc aluminum strip of sizes for lv winding of dist. transformers 25kva to 250kva.( in exchange of one kg of scrap including insulation coverage i.e. salvaged conductor), se copper winding wire (round) in sizes 11 to 22 swg., dpc copper winding wire (round) in sizes 11 to 22 swg., dpc copper strip of sizes for lv winding of distribution transformers 25kva to 250kva., se copper winding wire (round) in sizes 11 to 22 swg.( in exchange of one kg of scrap including insulation coverage ie salvaged conductor), dpc copper winding wire (round) in sizes 11 to 22 swg.( in exchange of one kg of scrap including insulation coverage ie salvaged conductor ), dpc copper strip of sizes for lv winding of distribution transformers 25kva to 250kva. ( in exchange of one kg of scrap including insulation coverage ie salvaged conductor ), lv. brass bush rods 12 mm, lv. brass bush rods 20.mm, lv. brass bush rods 25.mm, lv. brass bush rods 30mm, hv. brass bush rods 12 mm, buy back of scrap/old brass bush rods, cork washer for lt bushings big / small, cork washer for ht bushings big / small, lt rubber washers (small m12 & m20) (large m12 & m20), ht rubber washers, ms washers for lt, gutka for ht bush, hv bushing (11kv) 12mm, lv bushing 12mm, lv bushing 20mm, lv bushing 25mm, cotton tape 1 (size), length 25 mtr, nawar tape 1 (size), old cotton sari / cloth, rubberized cork sheet 4mm thick, rubberized cork sheet 5mm thick, cork strip 5mm thick, lethoride paper, electrical grade kraft paper, packing sheet 1 mm, packing sheet 1.5 mm, varnish dr. beck, m seal, fevicol, glass wool sleeves of sizes, backlite tubes, inch inch(i mtr length), packing gutties, manual operated oil pump, transformer oilas per the specifiction of is-335 amended from time to time, ms nuts andd bolts full thread size 1/2 in to 3 in, ms plug and caps 1/2", 3/4", 1", 1.1/4", 1.1/2"confirming to relevant is code amended upto date, film paper 7milsconfirming to relevant is code amended upto date
Tender For supply, termination installation, testing and commissioning of ventilation system on roof of paint shop of lower parel workshop along with complete installation, frame work of suitable size with ms 50mmx 50 mmx 5mm, cabling, cable try work, wiring and protection system with 4 pole 20a mcb for each and mcb board along with 2.5 sqmm cable 4 core and 10 sqmm cable from panel to distribution board for main supply and power full exhaust system of length and height minimum 1 meter with width minimum 400 mm, diameter blades 900 mm, blades rotational speed -620 r/min or more. air flow 30,000 m?/h, noise level shall be less than 70 db, power shall be minimum 750 watt with the flap system and motor starter of 1 hp or as per suitable and confirming to s/iec 60947-4-1 or latest. all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt i) 1993 and is:8623/1993, amended to date. termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 2.5. type test certificate from nabl or any other govt agency lab report shall be attached along with the offer without which offer will be rejected. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : providing of custom bid for services - transportation of assembled trolleys (with wheel sets) & wheel set or any other material related to icf /lhb / vande bharat coaches from coaching depot rewa to nominated workshop depot over indian railway
Tender For providing of custom bid for services - manpower cost for the work housekeeping of various shops/sections, common areas & toilet/washing areas and intensive cleaning of incoming and outgoing coaches in carriage workshop nwr jodhpur(48 months),custom bid for services - material cost for the work housekeeping of various shops/sections, common areas & toilet/washing areas and intensive cleaning of incoming and outgoing coaches in carriage workshop nwr jodhpur(48 months)
Tender For providing of custom bid for services - e tender for transportation of material like ir wheels brake blocks and em pads etc minimum carrying capacity 6 and half m ton from mmlp dadri to indian railway workshop shed or other locations for total 429792 km for the pe..
Tender For w acting for and on behalf of the president of india invites e-tenders against tender no e-73-dyceekgpw-cbc-26-27 closing date/time 01/07/2026 15:00 hrs. bidders will be able to submit their original/revisedbids upto closing date and time only. manual o ers are not allowed against this tender, and any such manual o erreceived shall be ignored.1. nit headername of workupgradation of cbc overhauling section and corrosion repair shop of wagonrepair shop, kharagpur workshop.bidding typenormal tendertender typeopenbidding systemsingle packet systemtender closing datetime01/07/2026 15:00date time of uploadingtender09/06/2026 16:38pre-bid conferencerequirednopre-bid conference datetimenot applicableadvertised value 2402108.76tendering section elegenbidding style single rate for tender bidding unitabove/below/parearnest money (rs.) 48100.00validity of offer ( days) 60tender doc. cost (rs.)0.00period of completion 18 monthscontract type works - general contract category expenditurebidding start date 17/06/2026are jv allowed to bid nonumber of jv memberallowed0are consortium allowedto bidnonumber of consortiummember allowed0ranking order for bidslowest to highest expenditure typecapital (works)2. schedules.no. itemcodeitem qtyqty unitunit ratebasic value escl.(%) amount biddingunitschedule () a-cost of supply of material for electrical work1712792.421a12.00numbers383500.00 767000.00 at par 767000.00description:- supply of incoming 1x 630a,4p, 50ka mdo type microprocessor based acb withipr1+ release & outgoing (i)2 x 320a,4p, 36ka thermal magnetic release with adjustable thermal &fixed magnetic mccb (ics=100%icu),(ii)2 x 200a,4p, 36ka thermal magnetic release withadjustable thermal & fixed magnetic mccb (ics=100%icu),(iii)4 x 100a,4p, 36ka thermal magneticrelease with adjustable thermal & fixed magnetic mccb (ics=100%icu) tted in lt panel box14swg crca sheet powder coated 4way cu busbar of suitable rating, indicator lamp, digitalmultifunction meter & all other accessories. mccb & acb make:- havellls/ lk/ schneider/siemens.2a210.00numbers 400.02 4000.20 at par 4000.20description:- supply of mcb metal enclosure 4 pole3a380.00numbers 413.00 33040.00 at par 33040.00description:- supply of pyramid insulator as per drawing4a470.00numbers 531.00 37170.00 at par 37170.00description:- supply of pin type insulators as per drawing.5a550.00numbers1121.00 56050.00 at par 56050.00description:- supply of gi-angle (40 x 40 x 06 mm) bracket 4 way with porcelain insulator as perdrawing suitable for overhead light.6a610.00numbers 248.98 2489.80 at par 2489.80description:- supply of mcb metal box 2 pole7a720.00numbers1323.96 26479.20 at par 26479.20description:- supply of 16/20/25a power unit (containing 4 module plate, starter, socket and plug)for ac unit.8a85.00numbers11434.20 57171.00 at par 57171.00description:- supply and testing of oscillating type bldc pedastal fan, 230 v,400 mm sweep,multi speed, remote/button controlled make- atomberg, havells, crompton, bajaj, usha, orient.9a9 150.00 metre1150.50 172575.00 at par 172575.00page 1 of 18run date/time: 09/06/2026 16:38:46kgp-workshop-electrical/south eastern rlytender documenttender no: e-73-dyceekgpw-cbc-26-27closing date/time: 01/07/2026 15:009description:- supply of hot dip galvanized 2mm thickness perforated cable tray of size 300 mmwidth and 50 mm height and complete accessories as per is, ie rules and site requirement10a10 50.00 metre 575.25 28762.50 at par 28762.50description:- supply of cable trays 2mm thickness size 100 x 50 mm gi, perforated (rmt) withcover complete and as per is, ie rules and site requirement.11a11 10.00numbers 180.54 1805.40 at par 1805.40description:- supply of combined switch socket box - 16 a, capton 5-in-1 combined switch andsocket with isi mark,as per is:3854 or latest12a122.00numbers34700.26 69400.52 at par 69400.52description:- supply of 4 pole mccb ,release range (80-200)a, breaking capacity 36 ka,microprocessor release with inbuilt earth pr
Tender For bid to ras tender for supply of disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed