Get complete information related to latest Hand Dryer Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hand Dryer Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hand Dryer Scrap Tenders.
Tender For corrigendum : camc (comprehensive annual maintenance contract) of hvac system (heating, ventilation and air conditioning system) at knowledge consortium of gujarat, ahmedabad
Tender For supply of various items of lab equipments for govt. p g college guna district guna (m.p.) under p m usha pariyojna 4th call - supply of various lab equipments items for govt. p g college guna district guna (m.p.) 4th call, waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr co
Tender For corrigendum : design, fabrication,supply, installation,testing and commissioning of solar steam cooking system consisting of scheffler dish concentrator of total 630 peoples and 2000 lpd solar water heating system at srpf camp of nagpur and chandrapur district
Tender For corrigendum : supply of removal of existing preheating chamber, blasting chamber with fume system, spray painting chamber along with connected accessories and utilities as per tech spec , supply of pre-heating system along with connected accessories as per tech spec , supply of shot blasting system with dust extraction system along with connected accessories as per tech spec , supply of automatic spray painting system with air filtration and ventilation system along with connected accessories as per tech spec , installation, testing and commissioning of pre heating system and connected accessories as per tech spec , installation, testing and commissioning of shot blasting system and connected accessories as per tech spec , installation, testing and commissioning of automatic spray painting system and connected accessories as per tech spec , civil works as per tech spec , spares and consumables as per tech spec
Tender For supply of lab equipments - purchase of lab equipments, four stroke petrol engine test rig specifications: single cylinder, 4-stroke spark ignition, petrol engine. air cooled rope brake arrangement with spring balance for loading . speed :1500 3500rpm power 3 hp. panel board for measuring speed with power supply and tacho generator setup, burette with tank assembly. load test test rig kit . heavy-duty fabricated ms base frame anti-vibration mounting arrangement powder-coated / painted finish , saybolt viscometer apparatus specifications: glass type: high-quality borosilicate glass tube. control type: manual energy regulator control. shape: rectangular bath with cylindrical test chamber. temperature range: ambient to 240 c oil bath temperature. humidity: up to 80% rh (non-condensing). power supply: 230 v ac, 50 hz. measuring range: 32 to 1000 sus(saybolt universal seconds). accuracy: as per astm d-88( 0.2 seconds). mounting type:benchtop. capacity:one cup(approximately 60 ml). control mode:manual operation. port size:standard orifice sizeas per astmd-88. features:oil bath with heater, thermoregulator, insulated outer body, orifice, receiver flask., cleveland open cup (coc) apparatus specifications: standard compliance: astm d92 / is 1448 (part 69) test method: open cup flash and fire point determination test cup: brass, precision machined with heat resistant handle heater: electric heater (1000 w 10% nickel chromium) with variable control heating rate: 5 c per minute (as per standard) temperature range: (-6 to 400) c thermometer: astm 11c or equivalent flame applicator: gas test flame with fine control valve body: stainless steel housing display: analog / digital temperature indicator power supply: 230v ac, 50 hz safety: overheat protection heat insulation, pensky-martens closed cup apparatus specifications: standard compliance: astm d93 / is 1448 (part 21) type: pensky-martens closed cup (motorized, digital type preferred) test cup: brass cup diameter: 50.7 50.8 mm capacity: minimum 70 ml stirring system: heater: electric heater 650 w 10% heating rate: 1 12 c/min adjustable ignition: pilot flame with automatic shutter mechanism temperature measurement: thermometer or digital sensor(ip-28c or astm) digital temperature display power supply: 230v ac, 50 hz safety: over-temperature cut-off flame safety control
Tender For corrigendum : repair or maintenance of central heating system and maintaining the equal air pressure inside the command building , repair or replacement of street lights, post top lantern lights, garden lights and allied work for cantt-19 and repair or replacement