Web Analytics Made Easy - StatCounter

Hand Held Detector Tenders

Get complete information related to latest Hand Held Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hand Held Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hand Held Detector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45353428 Due date: 04 Jun, 202604 Jun, 2026 7.38 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at indoor ward, eye ward, blood bank, admin building of sdh, gunupur rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including al

State Government

CTN :45353431 Due date: 04 Jun, 202604 Jun, 2026 10.38 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at new chc building muniguda rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofeng

State Government

CTN :45353459 Due date: 04 Jun, 202604 Jun, 2026 10.87 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at opd/ipd building bissamcuttack rayagada vide addition/alterations letter no- 8078 dated 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction o

Central Government And Public Sector

CTN :45336842 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For supply of set of fire detection equipment cards consisting of 03 items. (1) display board for fdupt.no.pi 6340.18 (2) controller card for fdu pt.no.pi 6340.16 (3) power card for fdupt.no.pi 6340.14. [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45335917 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For supply of set of cards for fire detection equipment of trolex make as per(1) display board for fdu-part no. p1 6340.18, qty-1 no. (2) controller card for fdu part no. p1 6340.16, qty-1 no. (3) power card for fdu part no. p1 6340.14, qty-1 no. set consist of 03 items in 03 nos. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

corporations/Associations/Others

CTN :45328583 Due date: 02 Jun, 202602 Jun, 2026 1.23 Crore
Tender For providing annual maintenance contract (amc) and one time repair for various electromechanical equipment installed at patsan bhawan, kolkata, west bengal. - fire fighting system , fire hydrant system , fire extinguishers , fire detection & alarm system, public address system , water treatment plant , sewage treatment plant , hvac system , hvac pumps , electrical panels , 750kva dry type transformer , 750kva dry type transformer , main lt panel (cum dg changeover panel ) , 400kvar capacitor panel , hvac panel , ventilation panel , lift panel, , fire panel , stp panel , wtp panel , isolator panel, , floor db panel, , plumbing panel , sump pump panel , lift lobby pressurization panel , submersible pump panel , 11kv vcb (ht panel) , dbs , toilet inline fan , ventilation fan , exhaust fan , fda,pa,talkback,fire hydrant,extinguisher and sprinkler , stp & wtp plant and sump pump , cctv, intercom, access control , primary chilled water pump , secondary chilled water pump , condenser water pump , secondary controler , cooling tower , ahu with conrol panel , tfa with conrol panel

CTN :45307274 Due date: 02 Jun, 202602 Jun, 2026 NA
Tender For providing of annual maintenance contract of integrated security and surveillance system - theft prevention, remote video monitoring, facility/asset protection, monitor operations, personal protective equipment detection solution; non-comprehensive; hardware, software, wireless system, n..

CTN :45209555 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For supply of buzzer, over speed fire detection alarm/ vigilance warning of cab equipment of wag-9 loco as per clw's spec. no.-clw/es /3/ 0078 (alt.-c). [ warranty period: 30 months after the date of delivery ] ]

CTN :45284583 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For supply of buzzer, over speed fire detection alarm/ vigilance warning of cab equipment of wag-9 loco as per clw's spec. no.-clw/es /3/ 0078 (alt.-c)

Central Government / Public Sector

CTN :45128385 Due date: 29 May, 202629 May, 2026 NA
Tender For replacement of defective / aged non rdso fire & smoke detection alarm system with rdso type in relay room, equipment room and battery room at 30 no. of station / locations and fire aspiration system in kzj - sc - wd, vkb - prli, khnp-kukt, dkj-mugr, pshp-bdcr, mtmi-sslm section (b & d routes) over sc division.
 Loading, Please wait...

Connect us via What's Up