Get complete information related to latest Hand Spray Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hand Spray Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hand Spray Pump Tenders.
Tender For auction sale of mild steel,mt scrap,plastic scrap,tin scrap,textile old,tentage old,helmet , jerrican , bucket all type , tank mule etc,engine assy dozer, engine assy kraz, engine assy safari etc,net mosquito, cap water proof, overall combination, puncho etc,simulator ( plastic body),cover outer different size,fire extinguisher,batery different size,foot pump, rotary pump/ fip, self starter all type etc,radiator all type,blanket,boot dms,air compressor all type, compressor all type, air condione ect,alluminium,woolen rags,canvas old,lath machine,wheel drum,server, scanner, fax machine, cpu all type, tv, laptop ect
Tender For supply of emergency diesel engine driven fire pump 36tph_obs and documentation for yard 16101 , services of engineers for emergency dies_ operation and maintenance training for yard 16101 , monthly warranty extension charges for yard 16101 , extra man-days for 1st year and 2nd year for yard 16101 , emergency diesel engine driven fire pump 36tph_obs and documentation for yard 16401 , services of engineers for emergency dies_ operation and maintenance training for yard 16401 , monthly warranty extension charges for yard 16401 , extra man-days for 1st and 2nd year for yard 16401 , emergency diesel engine driven fire pump 36tph_obs and documentation for yard 16402 , services of engineers for emergency dies_ operation and maintenance training for yard 16402 , monthly warranty extension charges for yard 16402 , extra man-days for 1st and 2nd year for yard 16402 , emergency diesel engine driven fire pump 36tph_obs and documentation for yard 16403 , services of engineers for emergency dies_ operation and maintenance training for yard 16403 , monthly warranty extension charges for yard 16403 , extra man-days for 1st and 2nd year for yard 16403 , emergency diesel engine driven fire pump 36tph_obs and documentation for yard 16404 , services of engineers for emergency dies_ operation and maintenance training for yard 16404 , monthly warranty extension charges for yard 16404 , extra man-days for 1st and 2nd year for yard 16404 , emergency diesel engine driven fire pump 36tph_obs and documentation for yard 16405 , services of engineers for emergency dies_ operation and maintenance training for yard 16405 , monthly warranty extension charges for yard 16405 , extra man-days for 1st and 2nd year for yard 16405 , emergency diesel engine driven fire pump 36tph_obs and documentation for yard 16406 , services of engineers for emergency dies_ operation and maintenance training for yard 16406 , monthly warranty extension charges for yard 16406 , extra man-days for 1st and 2nd year for yard 16406
Tender For corrigendum : supply of establishment of watermanship training centre including electrrical engineer equipment - 1.1. modular construction, easy/ fast installation/ anti-skid surface/ uv protected/ more stable/ excellent buoyancy. 1.2. dimensions-8ft x 6.5ft x 1.5ft (length x width x height). 1.3. buoyancy-1000 kg. 1.4. railings- ms railings epoxy coated with nut and bolts. 2.1 hand held fire extinguisher (2 nos). 2.2. obm 90 hp suzuki outboard motor with accessories (fuel tank, steering remote system propeller, toolkit) & manufacture recommended list of spares (mrls). 3.1. dimensions-4.7m x 2.1m x 0.50m (length x width x buoyancy dia), 05 x chambers and 08 x person capacity. 3.2. hull construction fiberglass, u.v. resistance gelcoat, epoxy resin with vacuum infusion system and sandwich core material. 3.3. engine-90hp 4 stroke remote control engine with steering system. 3.4. accessories - pair of oars, foot pump (electric & manual), repair kit. 4.1. open covered mechanical storage shed (30 ft x 40 ft x 15ft). 4.2. profile sheet 40x30, iron pipe 3x3 inch, parlin 2x2 inch, brick wall 100ftx36inch and 08 x tube light. 5.1. rcc ramp 4m wide x 12m long, rcc pilar 12x12 inch, steell rat 18mm and 12mm. 5.2. reinforced concrete (m25) with non-slip finish. 5.3. ramp rcc thickness 6 inch
Tender For repair and maint to various firefighting pump sets diesel engine driven pump sets, control panels fire mains, fire hydrants including repair replat of connected accessories at svn nsv mo(v) wed, ncb nofra and adjacent area under ge (utility-ii) (v)
Tender For supply of e 058 engine room lagging and covering sheet , e 059 the hydraulic mechanism of the weather deck , e 060 two in nos 65 mm to 50 mm fire main connector , e 091 fire and bilge pump not taking suction and sea water leakage , l 98 port side engine room blower not working
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire