Get complete information related to latest Hanger Block Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hanger Block Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hanger Block Tenders.
Tender For supply and application of insulation materials on pipe, equipment for part a and part b as per standard specification by providing all required materials in connection with the composite work for setting upof hpg-2, butene-1 and psa units atlepetkata - legends / notes for insulation workstypes of insulation : ih = insulation for heat conservation it = insulation for steam traced lines is = insulation for personal safety ic = cold insulation for anti-condensation ie = insulation for electrically traced lines ij = insulation for jacketed lines ik = insulation for dual insulated lines basic line surface materials : cs = carbon steel (including lt carbon steel), as = alloy steel, ss = stainless steelnotes :1. for insulation type it,tracer size and tracer numbers shall be as per specification.2. insulation thickness for ic where insulation material is poly urethane foam (puf) / poly isocyanurate (pic) + cellular glass includes outer layer of 50mm of cellular glass and inner layer of balance thickness of puf/pic.3. insulation for ie consists of inner layer of rockwool and outer layer of puf / pic. the thicknesses have been specified as thk(i) and thk(o) for inner and outer layers respectively., part a, hot insulation (units)providing thermal insulation including supply of all insulating and ancillary materials, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required, including transportation of materials to work site, duly inspected by 3rd party inspector(llyods/bv/dnv or any other client approved party) at manufacturers shop & sample check/inspection at site by eil construction inspector, applying insulation on surfaces as specified including all preparatory work there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with sheet cladding as per spec. , providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions of engineer-in-charge. (refer legend for applicable eil specification), insulation type : ih ; surface material : cs & as ; operating temp. range : upto 125 (deg c) ; insulation material : rockwool, pipes, nb 00.75 inches; thickness 25 mm, nb 01.00 inches; thickness 25 mm, nb 01.50 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, nb 03.00 inches; thickness 25 mm, nb 04.00 inches; thickness 25 mm, nb 06.00 inches; thickness 25 mm, blind flange assemblies, nb 00.75 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, valve assemblies, nb 00.75 inches; thickness 25 mm, insulation type : ih ; surface material : cs & as ; operating temp. range : 126 (deg c) to 350 (deg c) ; insulation material : rockwool, pipes, nb 00.50 inches; thickness 25 mm, nb 00.50 inches; thickness 40 mm, nb 00.75 inches; thickness 25 mm, nb 00.75 inches; thickness 40 mm, nb 00.75 inches; thickness 50 mm, nb 01.00 inches; thickness 25 mm, nb 01.00 inches; thickness 40 mm, nb 01.00 inches; thickness 50 mm, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 40 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 02.00 inches; thickness 65 mm, nb 03.00 inches; thickness 25 mm, nb 03.00 inches; thickness 40 mm, nb 03.00 inches; thickness 50 mm, nb 03.00 inches; thickness 65 mm, nb 04.00 inches; thickness 25 mm, nb 04.00 inches; thickness 40 mm, nb 04.00 inches; thickness 65 mm, nb 06.00 inches; thickness 40 mm, nb 06.00 inches; thickness 65 mm, flange assemblies, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 03.00 inches; thickn
Tender For supply of polythene insulated polythene sheathed armoured jelly filled telephone cable with poly -al moisture barrier 0.63 mm dia 50 pair to tec specification no. gr/cug-01/03 aug 2003 with latest amendment [ warranty period: 30 months after the date of delivery ]
Tender For supply of hangerblock for bolster suspension conforming to rdso str no: c-k202 am endment 1 of aug 2002. drg no : dc/emu - 0-5-007, alt : g/nil, type drg: icf. [ warranty perio d: 30 months after the date of delivery ]
Tender For supply of polythene insulated polythene sheathed armoured jelly filled telephone cable with poly-al moisture barrier 0.63 mm dia. 20 pair to specification no.irs:tc-41-97 with latest amendment. insp ection: rdso. [ warranty period: 30 months after the date of delivery ]
Tender For supply of hangerblock for bolster suspension to icf's drg. no. cc05106,alt.no.-e and rdso's str no.c-k 202 with amendment slip no.-1 of august 2002. [ warranty period: 30 mon ths after the date of delivery ]
Tender For supply of solid polythene insulated jelly fully filled, polythene sheathed underground telecom ca ble armoured cables with poly-al moisture barrier, 10 pair 0.50 mm conductor diameter as per tec sp ecification gr/cug-01/03 aug 2003. [ warranty period: 30 months after the date of delivery ]
Tender For supply of hangerblock for bolster suspension as per (1) rcf drg. no. cc-05106 alt-e or (2) icf drg.no. t-o-5-638, alt- c/13 specn: t-0-5-638 [ warranty period: 30 months after the d ate of delivery ]