Get complete information related to latest Heat Shrink Sleeves Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Heat Shrink Sleeves Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Heat Shrink Sleeves Tenders.
Tender For supply of spare parts for bd 80 veh - anabond red (175 gm)part no nk, araldite 175 gmpart no nk, cloth emery - 120part no nk, cloth emery - 180part no nk, cloth emery - 60part no nk, cloth malmalpart no nk, cloth white muslinpart no h28305000243, cotton wastepart no nk, electrod (e 900) 4 mmpart no 3439000147, electrodes welding ms gp 2.50 mmpart no g23439000016, female pinpart no nk, feviquickpart no nk, franch chalk powderpart no nk, halide sheet 0.5 mmpart no nk, halide sheet 1 mmpart no nk, hingespart no nk, hollow pipe 12 mmpart no nk, insulation tapepart no nk, iron rod 8 mmpart no nk, lt wire 2.5 sq mmpart no nk, m sealpart no h18010000084, male pinpart no nk, muskin tape 2 "/3" inchpart no nk, paint aluminium (silver) 1/2 ltrpart no h18010000114, paint red oxidepart no h18010000110, paint rfu ogpart no hi8010007499, paint syn enamel blackpart no h18010007482, paint syn enamel bluepart no nk, paint syn enamel whitepart no h18010000014, plastic tagpart no nk, ps greenpart no nk, puttypart no nk, ring snappart no 116mc11526, rust cleaner(zorrik 180 gm)part no nk, sodium hydroxide(caustic soda)part no h18040000019, solder soft 40-60(200grm=1pkt)part no nk, steel 40c8 r/bar dia 20 mm to is : 1570part no nk, stop push bottonpart no nk, strap 2"part no nk, thermal sleeve 8 mmpart no nk, thinnerpart no nk, thread tapepart no nk, welding electrode cast iron 3.15mm e 115part no nk, welding electrode ms dia 3.15 mmpart no nk
Tender For supply of overhauling kit for poh of casnub bogie having kbi make bmbs system confirming rdso spec. no. wd-23-bmbs-2008 rev-1 of amend 1 of sept. 2016 and drg. no. wd-08093-s-02, alt. 3 (one kit contains following 15 items) 1). pin: kbi part no. c162088 =4 nos, 2).pin: kbi part no. c162086 =4 nos,3). pin: kbi part no. c162087 =4 nos, 4). pin: kbi part no. 778111 =4 nos 5). pin kbi part no. 778112 =8 nos, 6). washer: kbi part no. 778084 =4 nos, 7). washer: kbi part no. c162641 =8 nos, 8). washer: kbi part no. c162060 =4 nos, 9). dowel sleeve kbi part no. c140446 =4 nos, 10). bush kbi part no. c140445 =4 nos, 11). split pin with washer: kbi part no. 476858 =16 nos, 12). bulb cotter: kbi part no. c162098 =12 nos, 13). apd for push rod suitable for kbi make bmbs =4 nos, 14). apd for primary and secondary brake beam suitable for kbi make bmbs = 8 nos. 15). anti drop plate (z-apd) as per drawing no. kp1981443=4 nos. accepted description: - overhauling kit for poh of casnub bogie "suitable for knorr design bmbs" confirming to rdso spec.no. wd-23-bmbs-2008 rev-1 of amend 1 of sept. 2016 and rdso drg. no. wd-08093-s-02, alt. 3 (one kit contains following 15 items) [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heatshrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh