Get complete information related to latest Heat Sink Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Heat Sink Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Heat Sink Tenders.
Tender For auction sale of depot non ferrous scrap - p.l. no. 98230025. condemned and unserviceable aluminium scrap consisting of hhp loco top gear case housing , front and rear covers , 25 kw alternator fans , oil catchers , heatsinks , pistons , busbar, strainer , labyrinth ring, chase cover, acc housing,earthing device housing parts ,emd strainer , light fittings , distributor valve parts , gmts non drive end frame , end shields of hhp loco traction motors , after cooler core , main reservoir tanks , end shields of dynamic braking fan motor and other loco / c&w aluminium components of sorts and sizes with / without very meagre quantity of ferrous, plastic, rubber, wool, fibre , brass, copper and other orginal attachments. as is where is basis. segregation and removal of attachments not permitted. note- cssd/goc electronic weigh bridge to be used for weighment.
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heatsink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s