Get complete information related to latest Heat Insulation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Heat Insulation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Heat Insulation Tenders.
Tender For insulation monitoring relay (imr) to monitor 3 phase power supply of voltage range 110 v ac, measuring range 1 - 100 k ohm, control voltage 24 - 240 v ac / dc output 1 c / 0 (spdt) contact system leakage capacitance 10 micro farad, as per contrel model no. ir140y-4, ri-r22 or abb model no. cm.1ws.2s or schnieder model no. vigil ohm/1md-1m10 or siemens model no. 3ug4581-1aw30 or dold model no. 1l5880 or voka suitable for installation in s1a6 as per rdso/pe/spec/ac/0184-2015 rev-1 [ warranty period: 30 months after the date of delivery ]
Tender For supply,installation and commisioning of automatic oil cooled auto transformer starter panel for vt pumpupto 400 hp. make-bch, hotline switchgear and control noida, bhopal electrical insulation pvt. ltd. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 250 va single phase, h class, insulation-6 kv, 750/415 v control transformer with 4a fuse in primary make ael/ramayaa/nacei/bhasin/pack ard/trolex/trinitron per rdso specification no rdso/pe/spec/ac/0203-2020 (rev-0). [ warranty period: 30 months after the date of delivery ]
Tender For insulation resistance monitor relay according to iec 61557-8:- 1) rated control supply voltage: 220 v ac +/-10% (min tolerance). 2) voltage of distribution system to be monitored : 240v/415v ac+/- 10% (min tolerance). 3) mounting: din rail 35 mm. 4) maximum permissible overall dimensions(wxhxd): 52.5x85.6x115 mm. 5) adjustable tripping setting range: 10-100 kilo ohm. (firm is to mention maximum overall dimension of their offered item) [ warranty period: 30 months after the date of delivery ]
Tender For insulation monitoring relay, 415v ac, 3 phase, neutral isolated, voltage range 0-500v ac, insulation measuring range 10k ohm to 150k ohm, control supply 24-240v ac/dc, place of installation - s1a7, used for insulation control of 415v in lhb type ac coaches, confirming to rdso specification no. rdso/pe/spec/ac-0184-2015 (rev-1), suitable for switch board cabinet of lhb type ac coaches. accepted make & cat no.: as per sr. no. 68 of rdso letter no. el/7.1.108/mssbc, dated 17.09.2021, [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of three vessels hot case or similar: - three vessels hot case pulf insulated, double walled sturdy carrier molded out of virgin food grade plastic polymers consisting of fully insulated plastic body and lid with attached soft polypropylene carry belt for easy carrying purpose, consisting of three non-magnetic stainless steel containers with stainless steel lid stainless steel lifter as per the details given below. capacity: -i) volume of fully insulated plastic body only without top insulated plastic body lid=2750 ml or more. ii) volume of one single stainless-steel container with stainless steel lid=650 ml or more. weight: -i) weight of onesingle stainless-steel container with stainless steel lid=115 gm or more. ii)weight of stainless-steel lifter (forstainless steel containers) =60 gm (min) iii)total weight of empty fully insulated double wall plastic body along with top insulated plastic body lid and soft polypropylene carry belt=550 gm(min). identification marksmarking: molded logo/brand of the company should be provided on button of the product. railway marking: the manufacture to do ?rpf? logo printing on the outer body of the hot case red colour. colour: stainless steel/silver. strap: adjustable shoulder strap (a handle of sufficient length should be provided for easy carrying purpose. heatinsulation: the temperature of food should not be less than 10 degree centigrade approx. from storage temperature normally after 05 to 06 hrs. [ warranty period: 30 months after the date of delivery ]
Tender For supply of supply of vrv-vrf copper pipe and insulation , refrigerant piping 2.2 tr dx split ac wallmount stand , refrigerant piping 2.2 tr dx split ac copper piping , drain piping 32 mm dia , control and transmission wiring- 4c x 2.5sqmm cable , control and transmission wiring- shielded 2c x 1.0 sqmm , r410a-r32 refrigerant charging , factory fabricated gss 22 g rectangular ducts , acoustic insulation with 25 mm class 1 , damper controller , 300mm dia flexible duct , rectangular mixing boxes , alumnium lenier grill , timer for hiwall split ac , 4 way cassette type indoor ac units capacity- 6.36tr-2400cfm duct indoor with remote controller , 4 way cassette type indoor ac units capacity- 5.5tr-2047cfm duct indoor with remote controller , 4 way cassette type indoor ac units capacity- 3.0tr-1183cfm 4way cassette indoor with remote controller , 4 way cassette type indoor ac units capacity- 2.0tr-1183cfm 4way compact cassette indoor with remote controller , 4 way cassette type indoor ac units capacity- 2.2tr-non vrv hiwall split indoor and outdoor with remote controller , central remote controller , 60 hp - out door unit , 10 hp - out door unit , 60 puls 14 hp outdoor unit ms stand , vrv-vrf multi connecting piping kit for odu , refnet- y joints , cable trays - 300mm-w x 100mm d x 1.8mm-thickness gi perforated cable tray with cover , installation and service charges for low side works , installation and service charges for high side works
Tender For tender for supply of sitc of 1.5 tr split ac uits , copper pipe 6.4 mm dia with tube thickness 0.8 mm with insulation , copper pipe 12.7 mm dia with tube thickness 0.8 mm with insulation , 25 mm c-pvc pipe , ms stand of suiatble size for outdoor unit , supply & fixing of control cum transmission wiring and ac power supply cable 3x2.5 sqmm , supply & fixing of control cum transmission wiring and ac power supply cable 4x1.5 sqmm , supplying and fixing dp sheet steel enclosure complete
Tender For supply of insulation monitoring relay 110v ac, measuring range 1 k ohm to 100 k ohm,control voltage range 24-240v ac/dc, output 1c/o (spdt) contact, system leakagecapacitance 10 micro farad. conforming to rdso specification no. rdso/pe/spec/ac/0184- 2015 (rev-1), used for insulation control 110v of lhb type ac coaches, accepted make & cat. no.: as per sr. no. 67 of the common bom list issued vide rdso letter no. el/7.1.108/mssbc dated 17.09.2021, or any other rdso-approved make. [ warranty period: 30 months after the date of delivery ]