Tender For providing and making of outdoor and indoor cable end termination with heatshrinkablejointingkit of 3.3kv and 11kv grade xlpe power cable at different places inside and outside of plant and colony premises of sawang washery.
Tender For corrigendum : tender for supply of spare parts for the maintenance works of substation : : -supply of 120 sqmm , 3 core 33kv al armoured cable , supply of 35 sqmm , 3.5 core straight through joint with cast resin compound including ferrules and other jointing materials for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. , supply of 70 sqmm , 3.5 core straight through joint with cast resin compound including ferrules and other jointing materials for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. , supply of 240 sqmm , 3.5 core straight through joint with cast resin compound including ferrules and other jointing materials for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. , supply of 300 sqmm , 3.5 core straight through joint with cast resin compound including ferrules and other jointing materials for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. , supply of 70sqmm , 3 core straight through cable jointing with heatshrinkablejointingkit complete with all accessories including ferrules suitable for following size of 3 core , xlpe aluminium conductor cable of 11 kv grade as required , supply of 120sqmm , 3 core straight through cable jointing with heatshrinkablejointingkit complete with all accessories including ferrules suitable for following size of 3 core , xlpe aluminium conductor cable of 11 kv grade as required , supply of 70 sqmm , 3 core indoor cable end termination with heatshrinkablejointingkit complete with all accessories including lugs suitable for following size of 3 core , xlpe aluminium conductor cable of 11 kv grade as required , supply of 120 sqmm , 3 core indoor cable end termination with heatshrinkablejointingkit complete with all accessories including lugs suitable for following size of 3 core , xlpe aluminium conductor cable of 11 kv grade as required , supply of 70sqmm , 3 core outdoor cable end termination with heatshrinkablejointingkit complete with all accessories including lugs suitable for following size of 3 core , xlpe aluminium conductor cable of 11 kv grade as required , supply of 120sqmm , 3 core outdoor cable end termination with heatshrinkablejointingkit complete with all accessories including lugs suitable for following size of 3 core , xlpe aluminium conductor cable of 11 kv grade as required , supply of 11kv , 95 sqmm , 3 core al armoured cable indoor type heatshrinkable end termination joint kit , supply of 11kv , 95 sqmm , 3 core al armoured cable outdoor type heatshrinkable end termination joint kit , cie 4 digit lcd display auto ranging digital earth resistance meter , cable cutter ratchet heavy duty for armoured cable upto 300 sqmm
Tender For tender for supply of external electrical works c c -chmbr 60x60x75cm , chmbr 90x90x100cm , chmbr 120x120x100 , rcc pipe (see doc) , hdpe pipe (see doc) , 7m oct pole (ref) , erect metal pole , 35w solar light , supply 12m mast , mast light itc , lay power cable , lay power cable , cable end term. , outdoor junc box , 6 swg gi wire , wiring 2x2.5 cu , wiring 2x2.5 cu
Tender For supply of point wiring group c , wiring with 2c 1. 5 sq mm cu wire in medium class pvc conduit , wiring with 2c 2. 5 sq mm cu wire in medium class pvc conduit , wiring with 2c 4sq mm cu wire in pvc conduit with earthing , wiring with 2c 6sq mm cu wire in pvc conduit with earthing , wiring with 4c 2. 5 sq mm cu wire in pvc conduit with earthing , wiring with 4c 4 sq mm cu wire in pvc conduit with earthing , s drawing 1c 1. 5 sq mm cu wire in extg conduit , s drawing 2c 1. 5 sq mm cu wire in extg conduit , s drawing 2c 4 sq mm cu wire in extg conduit , s fixing 20 mm medium pvc conduit , s fixing 25 mm medium pvc conduit , s fixing modular switch 5 or 6 amp , s fixing modular switch 15 or 16 amp , s fixing modular 5 or 6 amp socket outlet 3 pin , s fixing modular 15 or 16 amp socket outlet 6 pin , s fixing bell push modular , s fixing metal box 100 x 100 x 60 mm , s fixing metal box 150 x 75 x 60 mm , s fixing metal box 180 x 100 x 60 mm , s fixing metal box with lamnated sheet cover 1 or 2 module , s fixing metal box with lamnated sheet cover 3 module , s fixing metal box with lamnated sheet cover 4 module , s fixing metal box with lamnated sheet cover 6 module , s fixing metal box with lamnated sheet cover 8 module , s fixing metal box with lamnated sheet cover 12 module , s fixing box with 5 or 6 a modular switch and 3 pin 5 or 6 a modular sockets , s fixing box with 15 or 16 a modular switch and 6 pin 15 or 16a modular sockets , s fixing call bell buzzer 230 v ac , itc of ceiling fan incl wiring , numbering fans etc as required , s fixing 8 way double door mcb db 240v , s fixing 12 way double door mcb db 240v , s fixing 4 way double door mcb db 415v , s fixing single pole 5 to 32 amp mcb , s fixing 40 amp dp mcb , s fixing 63 amp triple pole and neutral mcb , s fixing 25 to 32 amp dp mcb with db , s fixing single pole blanking plate , s fixing 20mm pvc casing capping , s fixing led 2x2 feet 36w , s fixing led fitting 11w , sitc energy efficient celing fan 1200 mm , s fixing 2 step electronic fan regulator , s f exhaust fan 200 mm sweep 1 phase , s fixing ms perforated poweder coated painted cable tray 150mm x 50 mm x 1. 6mm , s fixing ms perforated poweder coated painted cable tray 300mm x 50 mm x 1. 6mm , s fixing metallic wall mounted air circulator fan , laying cable on wall size upto 35 sq mm , s and lay alcond cable 4c 10 sqmm xlpe , endtermi for 4 c 10 sq mm alu cable with brass compression glands , s fixing brass battern or angle holder incl connections , s fixing spike guard for 230v ac supply with 4 socket outlets , pf 8 swg gi wire , itc of 1. 5 or 2 tr split ac units , gas topping with r 22 or r 134 gas in ac ckt