Tender For corrigendum : supply of frame plate liner insert stud plus nuts,part no.6, material- enb zinc plated , set screw mechanical seal, part no.21, material-aisi 316 , adjusting screws and nut and washer, part no.15, material-ms zink plated , clamp bolt, part no.3 material-ms zink plated , clamp washer, part no.2 material ms zink plated , cover plate bolt and nuts, part no.27, material- en 8 , discharge joint ring, part no-10, material- synthetic rubber , frame plate bolt plus nuts, part no.20, material- is 1363 , frame plate liner insert, part no.8, material-hichrome , impeller, part no.9 material- hichrome , intake joint ring, part no.14material-synthetic rubber , keeper plate, part no.29, material-ms zink plated , mechanical seal, material- mod ps 4.625 inch , o ring for impeller, part no.24, material- synthetic rubber , o ring for sleeve, part no.4, material- synthetic rubber , oil breather, part no.30, material- ms , seal adopter, part no.23 material- hichrome , seal ring, part no.7 material-synthetic rubber , shaft sleeve, part no.5, material-astma743 cf8m , tapper roller bearing-6535-6580, part no.1 material-steel , throat bush, part no.11, material-hichrome , volute liner seal, part no.25, material-synthetic rubber , volute liner, part no.26, material- hichrome
Tender For procurement of spares for antico centrifugal pumps - complete impeller with nose with o-rings of impeller & impeller nose for nsrp 40 tbg v1j, complete volute casing including suction & discharge flanges with o-rings of suction and dischatge flanges for nsrp 40 tbg v1j, spring washer for impeller for nsrp 40 tbg v1j, complete impeller nose with o-ring for nsrp 40 tbg v1j, spring washer for casing for nsrp 40 tbg v1j, impeller screw o-ring for nsrp 40 tbg v1j, socket head cap screw of casing for nsrp 40 tbg v1j, impeller o-ring for nsrp 40 tbg v1j, casing body o-ring for nsrp 40 tbg v1j, shaft sleeve for nsrp 40 tbg v1j, complete impeller with nose with o-rings of impeller & impeller nose for nsrp 50 tbg v1j, complete volute casing including suction & discharge flanges with o-rings of suction and dischatge flanges for nsrp 50 tbg v1j, spring washer for casing for nsrp 50 tbg v1j, complete impeller nose with o-ring for nsrp 50 tbg v1j, impeller screw o-ring for nsrp 50 tbg v1j, impeller o-ring for nsrp 50 tbg v1j, spring washer for impeller for nsrp 50 tbg v1j, casing body o-ring for nsrp 40 tbg v1j, socket head cap screw of casing for nsrp 50 tbg v1j, shaft sleeve for nsrp 50 tbg v1j, complete impeller for vgp 160 pp, expeller with sleeve for vgp 160 pp, casing cover (back plate) for vgp 160 pp, complete volute casing for vgp 160 pp
Tender For supply of discharge hose assy,brush gear assy,assy sleeve cylinder,assy kit lined shoe,assy timing belt tensioner,electronic valve,hose with end ftg js,assy hose,check nut
Tender For tender for supply of tubes for condensor , gasket set for evaporator , oil separator for p28 class refrigeration plant , globe valve for liquid feed line to evaporators , safety relief valve for condenser/oil tank separator , angle valve 3-4inch npt for vent drain , globe valve for liquid line from condenser , core for filter drier filter drier c-r424 , globe cum check valve for discharge line , globe valve for oil line , check valve discharge line , thermostatic expansion valve , thermostatic expansion valve - cool room 7f potato , thermostatic expansion valve , thermosatatic expansion valve danfoss teat 20-20 , thermostatic expansion valve size-3-8inch x 1-2 flare , hex headed bolt m 8x1.25px 40l is1367ci8.8 , shock mounts for compressor -motor , impeller for sw pump , wearing ring for cw pump , shaft for sw pump , shaft sleeve for sw pump , shaft sleeve for cw pump , mechanical seal for sw pump , mechanical seal for cw pump , set of bearings for sw pump , set of bearings for cw pump , impeller ke for cw pump , beraing set for seawater pump motor , nab gate valve size-125nb pressue 6kg-cm2 , non driving end bearing deep groove ball-6319 pno 0029 , bearing set for 315 kw motor , pressure transmitter 0 to 16 kg-cm-2
Tender For supply of spacer sleeve suc wl 65 moc ci 44.7x61.35 model wl 65 8 hwd , blance disc wl 652 moc cl model wl 68 8 hwd , sft prot sleev discharge wl 50 65 hqd moc ci model wl 65 8 hws , sft prot sleev suction wl 50 65 hwd moc ci model wl 65 8 hwd , casing wear ring wl 65 moc ci 100 11.5 8 model wl 65 8 hwd , stage sleeve 44.7 30 wl 50 65 moc ci model wl 65 8 hwd , immpeller 185 11 wl 65 moc ci model wl 65 8 hwd , set of gasket and orings wl 65 8 hwd model wl 65 8 hwd
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heatshrinkablesleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh