Get complete information related to latest Heating Rod Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Heating Rod Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Heating Rod Tenders.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For supply of boiler plant job work automatic drum level control system of boiler no 1 2 and 3 complete penal overhauling calibration and recommissioning , re wiring of multichannel temp. monitoring laying of temp compensating cable jo fixing of temp series and recommissioning of panels , power turbine pannel job work repairing, calibration of digital temp jo monitoring panel avr acb for power turbine pannel and re wiring of the complete panel and its recommissioning , boiling house job work repairing, overhauling, complete re wiring and recommissioning desuper heating system in the exhaust line sto automatically control temp , repairing overhauling and recommissioning automatically control system jo super heated wash water for c by f machine , repairing and calibration of temp monitoring panels for rj by sj by inj c and exhaust steam and its commissioning after laying cable and fixing temp sensor * /bid number : gem/2026/b/7717241 + /dated: 27-06-2026 ' ' / bid document 1 / 11
Tender For auction sale of depot miscellaneous scrap - 98414501: cond. & u/s. electrical scrap consiting of inverter ,transformer for pre cooling, battery charger sorts and size, stabilizer, current regulators,ac/dc welding rectifier/plant,chokes, meters, capacitors, led lights/tube, vacuum cleaner, knob, torch lights of sorts and sizes, coach guidence parts, switches of various types, electrical parts, ballast, street lights, nugger, chokes, chargers, regulator, pre cooling switch,roof mounted electric loco ac cab,frequency controller, starter, fuse, terminals,timer relay, kwh meters, circuit board, amplifier, panel board, led light,socket,tube light holder, multi colour lamp, digital tempreature meter, chargeable lamp, soldering iron, tester, volt meter, various type of meters, insulation tester, megger,solar board and water heater,solar sets, analog starter,tlb instrument,different type of dlb instrument,boost charger, sms alert,holder, electric detector, ethernet card, relay panel, ups, smps atx, lan extender,port switch, media converters, optical fiber cable equipment, ethernet switch,ara terminal/fuse, recttifier,dc dc converter, earth electrod,vhm charger,head lamp, relay timer ,led lamp,led shunt routesolar panel,spd,spt, trasmitter,receiver,alarm system,smr ei, cab ac,pressure gauge, multimeter, heating elements, speaker, amplifier, lamp shades, speedometer,vcd,different type of relay,base assembly,pcb card,program switch,bl box,different type of ammeter,pedal switch,ups various,fl choke,single phase meter,mcb various amps,electronic timer switch,single phasing preventer, ballast off size,capacitors of various sizes,fan regulater, and such other similar electrical scrap as is where is condition. note: 1).if any non ferrous items found in loose conditon should be returned to the custodian,(2) pick and choose not permitted. (3) crane/jcb loading permitted.location: tree no.04 ,middle of scrap yard /ssd/ptj.