Tender For augmentation of central heating system by way of s.i.t.c of hot water generator of capacity 06 lac kcal/hr along with allied works at govt. super specialty hospital, srinagar
Tender For repair and maintenance of central/ package type ac plants, duct and cooling tower/ hot water generator etc at various places at af station bhisiana under ge (af) bhisiana
Tender For corrigendum : design, supply, installation testing and commissioning of hsd fired hot water generator based central heating system for tb hospital kargil
Tender For procurement of equipment, instrument, machineries, tools etc. related to laboratories and workshops of mechanical, electrical, civil, chemical engineering and science and humanities departments of hooghly inst of tech. - v notch channel test section: size: 250mm wide, 180mm deep; 600mmlong.materials : made with m.s lined with fiber or s.s 304baffle and deepened entry section for steadying water supply.arrangement for 7 fixing interchangeable notches.set of three brass notchesv notch (60 , 45 ).rectangular notch, electric oven size: 24 x 24 x 24- 03 shelvesspecification: vertical model , triple walled construction: front opening door, top mounted control panel for easy access, inner wall made of stainless steel with mirror polish, outer body made of mild steel with powder coat finish electrically operated thermostat with corresponding indicators. nichrome made long lasting heatingelements, high grade glass wool insulation, g.i. made wire mesh shelves with adjustable runners., adsorption isotherm apparatusmagnetic stirrer in multi-position 6 and erlenmeyer flasks with lids (125 ml. - six nos.), distillation unit 1.distillation column : material stainless steel, dia 110mm, seven sieve trays.pressure gauge: bourdon type, 0-2 kg/cm2.rotameter: for cooling water flow rate measurement.steam generator: made of stainless steel, provided with pressure gauge & level indicator, safety valve & insulated with ceramic wool and cladding with aluminium foil.reflux divider: special arrangement to change r/d ratio automatically. condenser: shell & tube type made of stainless steel.bottom product tank: made of stainless steel, capacity 5 ltrs.distillate tank: made of stainless steel, capacity 5 ltrs.heater: nichrome wire heater.temp. sensors: rtd pt-100 typecontrol panel comprises of:digital temp. controller : 0-199.9 c, for steam reboilerdigital temp. indicator : 0-199.9 c, with multi-channel switchwith standard make on/off switch, mains indicator etc.2. flow measurement: rotameter for cold water for condenserdistillation still: material- stainless steel, capacity 5 ltrs (approx.) insulated with ceramic wool and cladding with aluminum foil.condenser: concentric tube type (material- stainless steel)distillate tank: material- stainless steel, capacity 2 ltrs.heater: nichrome wire heater.control panel comprises of :digital temp. controller: 0-199.9 c, rtd pt-100 type (for steam generator)digital temp. indicator: 0-199.9 c with multi-channel switch.temp. sensors: rtd pt-100 typewith standard make on/off switch, mains indicator, set up to determine the linear expansion co-efficient of a metal rod.material of metal bar: copper, length of metal bar(total):500mm, dia: 25mm, no of thermocouples mounted on the bar:6 , no of thermocouples in the insulated shell: 2, heater: band type, cooling jacket dia:75mm, no of thermocouples:10, ammeter: 0-5amp, voltmeter: -0-300v, dimmerstate:1000w, temp indicator: 0-300oc, experimental set up of bricks/walls in series for conductivity measurementdiameter of slab:0.3 m, thickness of bakelite, wood and ms plates: 0.012 m, temp of indicator: 0-300oc, ammeter - 0-5amp, voltmeter- 0-300v,heater: mica type, dimmer state: 1000w, vacuum filtration apparatus with buckner funnel apparatus.material porcelain, for use with (application)suction filtration, product type buchner funnel, glass reciver - 2000 ml, 5000ml , (customised), grade 41 filter paper pkt/ 100, concentric tube heat exchanger apparatusinner copper tube i.d, 12.7mm. and outer g. i. pipe i. d. 15mm. approx. and 1.5m. length.2. thermometers - 4 nos.3. measuring flask - 1 lit. capacity.4. geyser-3 kw. single phase.services required-1. 220v, 15a, stabilized single-phase ac supply.2. floor area - 3m x i m x 1 m height.concentric tube heat exchanger: (a)plain tube ( water to water ):the apparatus consists of two concentric tubes. inner tube consists of copper tube through which hot water flows. while the outer tube consists of gi pipe through which cold wat
Tender For corrigendum : special repair/ upgradation of e.i in the civil hospital (block-a, b, c and d), sec.-6, panchkula. (upgradation / special repair of existing 3 x 300 tr. water chilling units plant with primary / secondary pumps and hot water generator only).
Tender For repair and maintenance of solar water heating system, hot water generator plant, water disinsfection, water treatment chemicals including connected works at various water supply installation under ge ima dehradun.
Tender For supplying all labour, material and t&p for laying of pipe lines, supplying & fiting of sluice valves, construction of valve chamber, providing fhtc in connection with pws to tumbagada, andanda & sapuakhata under patrapur block. - annexure - a, laying of pipe lines, fiting of sluice valves construction of valve chamber providing fhtc in connection with pws to tumbagada, supplying all labour and t&p for earth work in all kinds of soil within 50 m initial lead and 1.5 m initial lift including rough dressing and leveling etc., in foundation and plinth as per direction of engineer in-charge., supplying all material, labour , t&p for laying of following od hdpepipes conforming to is 4984-2016 and specials of the following outside diameter and class-4 to class-5 and jointing by fusion welding method including testing etc. all complete as per direction of engineer-in-charge, 160mm dia o.d. hdpe. pipe (including pipe cost) pe100, pn-06, 110mm dia o.d. hdpe. pipe (including pipe cost) pe100, pn-06, 90mm dia o.d. hdpe. pipe (including pipe cost) pe100, pn-06, supplying all labour, t&p for filling in pipe line trenches with excavated materials including watering etc., all complete including proper care to the laid pipe lines to prevent damages of pipes and specials as per the direction of engineer-in-charge., supplying all labour, materials, and t&p for drilling perfectly horizontal bore of required dia so as to accommodate following size hdpe. pipe line into the hole including inserting the pipe with out disrupting the traffic or cutting road including jointing with water main pipe lines etc, (excluding cost of pvc pipe) and as per the direction of engineer-in-charge, 160 mm dia hdpe pipe, supplying all labour and t&p for cutting cement concrete road for taking pipe line etc., complete and as per direction of engineer-in-charge., supplying all materials, labour t&p for making good to the damages of cutting of cement concrete road for taking pipe line and with 40 mm size crusher broken metal concrete etc., cc (1:4:8) of thickness 0.10 mtr and top 12 mm size crusher broken chip;s concrete cc(1:2:4) of thickness 0.075 mtrs including all cost, conveyance, royality of materials including watering, curing and ramming etc., all complete and as per specification and direction of engineer-in-charge, supplying all materials, labour and t&p for fixing of following sizes of c.i. sluice / non return valves with double flanged ends for water works purpose for following nominal diameter including cost of nuts and bolts, rubber insertion as per specification etc., complete., 150 mm dia c.i s.v, 150 mm dia c.i n.r.v, 100 mm dia c.i s.v, 80 mm dia c.i s.v, supplying all materials, labour and t&p for fixing of 15mm to 25 mm dia single air valve including fitting of required pvc service saddle for water works purpose for following diameter, including drilling the water main as per specification etc., complete., supplying all materials, labour, t&p for construction of brick masonry sluice valve and non return valve chambers of internal size 90x90x120cm with all lead royalty etc. such as earth work excavation, bed concrete with c.c. (1:4:8), kb brick in c.m. (1:6), 12mm cement plaster with c.m. (1:4), rcc cover slab with cc 1:2:4 etc., and as per approved p.h. drawing and design etc., complete and direction of engineer-in-charge., supplying all materials, labour and t&p for fabricating, fitting and fixing with specials at the required site using hot dip galvanized pipes of medium class and standard weight of reputed make (tata / zindal make) confirming to is 1239(p.1)2004/is:1161 of the following dia including cutting the pipes and flanges drilling the bolt holes matching the pipes flanges and jointing with proper gradient and alignment, welding with using electrodes, fitting, fixing using mobile diesel generator set etc., complete as per direction of engineer-in-charge to be used to cross drainage work incl