Web Analytics Made Easy - StatCounter

Hectometer Tenders

Get complete information related to latest Hectometer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hectometer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hectometer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :43946001 Due date: 27 Feb, 202627 Feb, 2026 38.71 Lacs
Tender For corrigendum : supply of digital mr nursery -digital terrain modeling data topographical features , digital topographical led 32 inch smart 512 mb panel 4k , digital conventional sign led 32 inch smart 512 mb panel 4k , direction finding iso resin realistic 3d models , digital directional finding led 32 inch smart 512 mb panel 4k , soft vertical cladding supply and installation , soft celling cladding supply and installation , led controlled illumination with installation for creation required lux level on each model , portable pedestal mode of hdmr 12mm and 18mm having wall mounted male female system led illumination embedded type size 3 x 3 x 2. 5 ft , digital astro navigation

CTN :44107948 Due date: 12 Mar, 202612 Mar, 2026 NA
Tender For supply of jrs bagging machine spares - pan support bracket for load cell assembly of ubm-85 bagging machine make : jasubhai engineering pvt. ltd , spares for bagging machine equipment : jrs bagging machine model : ubm-85 make : jrs supplier : jasubhai material handling systems pvt ltd flexible jaw connection (rubber) area : bag holding , swinging baffle for inlet assembly (spout assembly) of ubm -85 bagging machine make : jasubhai engineering pvt.ltd , digital bag counter mounting : flush panel mounting panel cut out size: 29mm x 71mm. (+/- 2mm) display : digital led display (seven segment) display size : 6 digit, 0. 3 inch height display colour : red. number of input channels: one input : potential free contact range : 999999 counts. counting direction : upward reset option : required i) on front panel. ii) remote reset ( via rear terminals) output : not required power supply : 24 vdc power comsumption : 5 va max. temperature : 20 to 50 deg.c humidity : 95% rh. housing : flame retardent plastic. protection level: ip 65 weight : approx 110 grams , pneumatic cylinder, 40 x 100 stroke with ct(female)with mounting, piston rod end block and piston rod end pin for dribble valve, piston shaft thread-npt , pneumatic cylinder, 40 x 100 stroke with rc mounting, piston rod end block and piston rod end pin, for bomb pan door, piston shaft thread-npt , pneumatic cylinder, 80 x 60 stroke with ct with mounting, piston rod end block and piston rod end pin, for bb80, piston shaft thread-npt , repair kit for 80 x 60 ct cylinder including cup, gland o-ring, guide and wiper , relay board for jasubhai jb07 bagging machine controller / control panel, plc relay for jasubhai jb07 bagging machine controller / control panel, timer for jasubhai jb07 bagging machine controller / control panel, emi filter for jasubhai jb07 bagging machine controller / control panel , repair kit for 40 x 100 ct cylinder including cup, gland o-ring, guide and wiper , repair kit for 40 x 100 rc cylinder including cup, gland o-ring, guide and wiper , complete pneumatic bb – 80 bag holder assembly with 2 nos. cylinder, bag feeler sensor, bag clamp sensor assembly material of construction : ss for jasubhai bag. machine- ubm 85) , spare ocp indicator for ubm 85 net weighing/bagging machine make : jasubhai engg. pvt ltd model: jb rd 01 , ss 316 weigh pan with cylinders for jasubhai bagging machine-ubm 85) , smps for jasubhai jb07 bagging machine controller / control panel , inductive slot sensor make : pepperl + fuchs model : sj 15 - e2 slot width : 15 mm operating voltage: 10-30 vdc connection type : 2 meter pvc cable protection : ip 67

CTN :44010360 Due date: 24 Feb, 202624 Feb, 2026 NA
Tender For tender for supply of m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after re

corporations/Associations/Others

CTN :43864268 Due date: 26 Feb, 202626 Feb, 2026 54.98 Lacs
Tender For arm electrical works esic and esis campuses at thathaneri, ponnagaram, maninagaram under madurai region for a period of 12 months - engaging of 1 no charge electricean having c licence holder of day to day maintenance of electrical maintenance works and to monitor these works are properly attended and to take care of complaints arised related to repairs / replacement of damaged fittings / fixtures in the campus such as switches, sockets, switch boards, ht/lt panels , mcbs, mcb dbs, mccbs, sfus, fsus etc., and all types of fans / light fittings, ug cables etc., complete all as directed by the engineer-in-charge. ( 01 no.) (qualification: diploma in electrical engineering with 10 years related experience/iti with 12 years or experience (supervisory) in maintenance job) (qualification: iti certificate with 03 years experience in operation of 11kv / 415v substation and equipment and dg sets along with valid 11kv /415v supervisor permit /c- certificate/grade c-license holder) (higly skilled). he is resposonsible to maintain & update the all logbook of preventive maintenace e&m equipment(lifts,panels,substation,dg sets,fire equipment,ro,stp&etp etc...) with respective staff.[1 no c licence holder ( highly skilled)]. note:-1. he is the responsible for ht metering cubicle to monitor & maintain all parameter readings.2. he is the responsible for timely calibration of ht vcbs, lt acbs/mccbs and earth fault relays and over current relays.3. he is the responsible for ht panels, transformers, acbs, mccbs, apfc panels with connected capacitor banks, power contactors & relays, up keep & maintain records for earth results in the ht & lt installations as per the direction of engr-in-charge.4. during main eb supply failure to monitor the running of stand by dg sets and maintain the plant running record book with all parameters and earth test register & insulation test register, fire alaram, smoke detection and fire fighting register all as directed.5. to maintain the eb shutdown register & obtain the necessary signature from eb authorities . (it should be talley with stand by dg set prrb), engaging lift operator cum electrician for day to day ( 1 shift /day in gen shift) lift operator is responsible for the safe operation of elevators/ lifts.checking of lift condition, to carry out rescue operation and following up with oem for pm & break down calls etc.., to make it in proper working condition etc.., here are some common duties and tasks associated with this roleof lift operator is to assist passengers in safely while loading and unloading and to ensure the safety and comfort of passengers during lift operations.maintenance: operators maintain the lift area, keeping it clean and organized. they also implement emergency procedures when necessary.evacuation: in case of disabled lifts or emergencies, lift operators evacuate passengers as per established protocols.qualification of lift operator: iti electrician with 3 years experience operation & maintain of lifts.- 1 nos (01 lift operator cum electrician for esih thathaneri), engaging electrician cum substaion attendant cum dg operator cum panel opearator for day to day ( in 3 shifts /gen shift) operation of substation, dg sets, lt panels , mcbs, mcb dbs, mccbs, sfus fsus etc and maintenance of electrical works like repairs to internal and external electric supply by replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, lt panels , mcbs, mcb dbs, mccbs, sfus fsus etc and all types of fans/ light fittings, oh lines, ug cables, dg set etc complete all as directed by the engineer-in-charge. and maintain logbooks along with shift register to be updated daily etc to be maintained as directed by engineer-incharge..electrician skilled (iti certificate with 3 years experience)- 4 nos note:1. he will maintain the shut down cum log book register and duly enter all the parameters.2. duri
 Loading, Please wait...

Connect us via What's Up