Web Analytics Made Easy - StatCounter

Helium Tenders

Get complete information related to latest Helium Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Helium Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Helium Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45731389 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of refrigerant gas r407c as per is:5610/1993(second revision) in 10 kgs capacity cylinder to is:3196 part 1 .(note: cylinders are in non returnable basis only and gas should be in 10 kg cylinder). [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45737322 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of eco-friendly refrigerant gas r-407c suitable for rmpu. note: gas is to be supplied in firms own 45kg cylinder on a returnable basis as per drg.no. na specn: rdso/pe/spec/ac/0134-2009(rev-0)/ na [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

Central Government/Public Sector

CTN :45713891 Due date: 20 Jul, 202620 Jul, 2026 20.00 Lacs
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20

corporations/Associations/Others

CTN :43775908 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : supply erection and commissioning of 03 nos of refrigerant type h2 gas driers for 2 x 600mw rtps dvc

Central Government/Public Sector

CTN :45739529 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For procurement of helium gas for b-05

CTN :45358214 Due date: 13 Jul, 202613 Jul, 2026 18.60 Lacs
Tender For corrigendum : tn-18368 supply of various electrical items at kstps, kota - supply of 3 phase, 415v lt motors for unit #1 to 7 at kstps, kota., supply and retrofitting of oltc of unit auxiliary transformer-4b at kstps, kota., supply of conveyor carrying idler frame & carrying idler frame troughing trainer for conveyor system in chp area., supply, installation, testing & commissioning of vaccum type gaseous chlorinator system capacity up to 20kg/hr with all accessories for pre treatment plant clarifier-iii for u# 6 & 7 of kstps, kota., supply of submersible dewatering/ mud pumps for cw, bcw & dmcw area of kstps, kota. kst, supply of middle collectors (laterals/intrabed distributors) for strong acid cation vessels of dm plant, stage-ll, kstps, kota., supply of various electrical items at kstps, kota., supply of portable and trolley mounted fire-extinguisher of different capacities for first-aid fire fighting system (extinguisher) installed at kstps, kota., supply of valves at kstps, kota., supply of misc. rubber items at kstps, kota., repair/machining of components of turbine & auxiliaries of unit 1 to 7 of kstps, kota, online helium leak detection test of condenser vacuum zone of unit # 1 to 7 (stage i to v) of kstps, kota, day to day joinery works inside & outside plant site, kstps, kota, capital, routine & breakdown maintenance of c&i instruments and equipments of stage-i to v, analyser, dm plant, clarifier, ics and cctv systems at kstps, kota., annual rate contract for 6.6kv vpi and non vpi ht motor rewinding from 175 kw to 4000 kw with new coils of insulation class 'f' and other additional works of stator and rotor.

CTN :45357098 Due date: 13 Jul, 202613 Jul, 2026 18.60 Lacs
Tender For corrigendum : supply of various electrical items at kstps, kota- supply of 3 phase, 415v lt motors for unit #1 to 7 at kstps, kota. , supply and retrofitting of oltc of unit auxiliary transformer-4b at kstps, kota. , supply of conveyor carrying idler frame & carrying idler frame troughing trainer for conveyor system in chp area. , supply, installation, testing & commissioning of vaccum type gaseous chlorinator system capacity up to 20kg/hr with all accessories for pre treatment plant clarifer-iii for u# 6 & 7 of kstps, kota , supply of submersible dewatering/ mud pumps for cw, bcw & dmcw area of kstps, kota , supply of middle collectors (laterals/intrabed distributors) for strong acid cation vessels of dm plant, stage-li, kstps, kota , supply of various electrical items at kstps, kota , supply of portable and trolley mounted fire-extinguisher of different capacities for first-aid fire fighting system (extinguisher) installied at kstps, kota , supply of valves at kstps, kota. , supply of misc. rubber items at kstps, kota. , repair/machining of components of turbine & auxiliaries of unit 1 to 7 of kstps, kota , online helium leak detection test of condenser vacuum zone of unit # 1 to 7 (stage i to v) of kstps, kota , day to day joinery works inside & outside plant site, kstps, kota , capital, routine & breakdown maintenance of c&i instruments and equipments of stage-i to v, analyser, dm plant, clarifier, ics and cctv systems at kstps,kota , annual rate contract for 6.6kvvpi and non vpiht motor rewinding from 175kw to 4000 kw with new coils of insulation class fand other additional works of stator and rotor
 Loading, Please wait...

Connect us via What's Up