Web Analytics Made Easy - StatCounter

High Performance Liquid Chromatograph Tenders

Get complete information related to latest High Performance Liquid Chromatograph Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic High Performance Liquid Chromatograph Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding High Performance Liquid Chromatograph Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45347363 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply of ultra high performance liquid chromatography (uplc)

CTN :45692458 Due date: 15 Jul, 202615 Jul, 2026 75.91 Lacs
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r

CTN :45695198 Due date: 15 Jul, 202615 Jul, 2026 285
Tender For supply of lab consumables to sub-divisional govt. hospital kundapura, udupi district for the year 2026-27. - rapid competitive immunochromatographic assay (multidrug kit)_ _ _, bovine albumin 22 percentage_ _ _, normal saline 500 ml_ _ _, coombs reagents/ anti human globulin reagents - 5ml_ _ _, anti h lectin - 5ml_ _ _, anti a1b lectin - 5ml_ _ _, anti a 1 lectin - 5ml_ _ _, abd blood group kit ( blend of igm & igg) - 5ml_ _ _, ahg (coombs) test card_ _ _, octoplus complete grouping card_ _ _, diluent 2 liss solution 250 ml_ _ _, abo/rho (d) forward grouping confirmation cards_ _ _, gel card system - work station _ _ _, gel card system - catridge warmer_ _ _, gel card system - centrifuge _ _ _, hot air oven_ _ _, rubber teats _ _ _, test tube racks _ _ _, dropper_ _ _, blotting/ tissue paper_ _ _, glass tubes (7.5 to 10 mm)_ _ _, glass slides ( 1x 2 )_ _ _, heamotology reagents 7 part_ _ _, heamotology instrument with body fluid 6 part _ _ _, widal kit (1x 5 ml)_ _ _, micro tips box_ _ _, blue tips 1000s_ _ _, yellow tips 500s_ _ _, micro pipette 500ml_ _ _, micro pipette 10-100_ _ _, pasteur pipette_ _ _, urine analyser urine strips1/11 para -100s_ _ _, urine analyser _ _ _, slide lamp for blood grouping_ _ _, pap smear kit disposable (eto) sterile_ _ _, staining jar malaria (glass)_ _ _, slide preserving box (1-100 slides)_ _ _, needle dispensor (without burner)_ _ _, plastic container 3kg (wide mouth)_ _ _, plastic container 5 kg (wide mouth )_ _ _, tourniquet_ _ _, marker pens_ _ _, sample rack (vaccutainer)_ _ _, micropipette stand_ _ _, discarding jar_ _ _, arm rest pad_ _ _, rotator (slide)_ _ _, centrifuge brush less -12 tubes_ _ _, micropipette (1-100)_ _ _, micropipette (0-50)_ _ _, micropipette (100-500)_ _ _, micropipette (100-1000)_ _ _, binocular microscope (labomed)_ _ _, hot air oven 12x12x12_ _ _, incubator 12x12x12x12_ _ _, electrolyte analyser _ _ _, troponin rapid kit _ _ _, iron reagents_ _ _, prolactin reagents _ _ _, aptt reagents _ _ _, aptt coagulation instrument _ _ _, matrix warmer_ _ _, matrix centrifuge _ _ _, matrix instruments _ _ _, coombs test reagents _ _ _, reticulocyte reagents _ _ _, haematology machine with reticulocyte counter_ _ _, clia hiv reagents _ _ _, electropheresis machine _ _ _, rubella rapid kit _ _ _, procalcitonin reagents _ _ _, albert stain_ _ _, iron kit_ _ _, clia machine _ _ _, g6pd machine_ _ _, hplc reagents _ _ _, hplc with thalassemia (high performance liquid chromatography)_ _ _, fdp reagents _ _ _, fdp - coagulation automated machine _ _ _, rdt for kala azar _ _ _, via chemical _ _ _, sickle cell anemia reagent_ _ _, elisa machine - reader and washer _ _ _, throat swab sticks (100s)_ _ _, media plates (each)_ _ _, blood culture broth(bhi) bottles (1 each)_ _ _, formalin -10% (500ml)_ _ _, biochemical (1kit)_ _ _, ada(1kit)_ _ _, ldh(2 x 30ml)_ _ _, protein (kit)_ _ _, distilled water ( for pap smear)(5 litre)_ _ _, pap stains kit(100 ml)_ _ _, alcohol(500ml)_ _ _, ra factor reagent kit (35t)_ _ _, anti ccp reagent kit (96t)_ _ _, rubella igg reagent kit (96t)_ _ _, s vitamin d reagent (96t)_ _ _, total ige reagent (96t)_ _ _, s vitamin b12 reagent kit (96t)_ _ _, s psa reagent kit (10t)_ _ _, s procalcitonin reagent kit (25t)_ _ _, s cea reagent kit (96t)_ _ _, s ca-125 reagent kit (96t)_ _ _, s alfa feto protein reagent (96t)_ _ _, s anti mullerian hormone (amh) reagent kit (96t)_ _ _, s prolactin reagent kit (25t)_ _ _, s beta hcg reagent kit (50t)_ _ _, mantoux reagent 5tu/10tu(5ml)_ _ _, acetic acid (500ml)_ _ _, cavity slide (10s)_ _ _, thermocol box_ _ _, transport media and container (100s)_ _ _, throat swab stick (100s)_ _ _, eosin yellow stains (125ml)_ _ _, gram iodine (250ml)_ _ _, gram crystal violet stain (500ml)_ _ _, gram stain (4 x 125ml)_ _ _, serum magnesium reagent kit (25ml)_ _ _, ldh reagent kit (25ml)_ _ _, total iron binding capacity (1 kit)_ _ _, ggt reagent kit (25ml)_ _ _, iron & tibc kit(35ml)_ _ _, igm reagent kit for salmonella

State Government

CTN :45671317 Due date: 06 Jul, 202606 Jul, 2026 28.00 Lacs
Tender For supply and installation of high performance liquid chromatography hplc

CTN :45212680 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : providing of customized amc/cmc for pre-owned products - high performance liquid chromatography (hplc); waters india pvt ltd waters e2695 2010; annual maintenance contract (amc); as per scope of work; no

CTN :45675923 Due date: 07 Jul, 202607 Jul, 2026 12.80 Lacs
Tender For supply of high performance liquid chromatography to sharnbasva university kalaburagi, karnataka

CTN :45362402 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For corrigendum : supply of high performance liquid chromatography (hplc) system

CTN :45619225 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For ultra-high performance liquid chromatography (uhplc) with mass spectrometry

CTN :45516317 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For purchase of ultra high performance liquid chromatography system (uhplc) - 01 no.

CTN :45402993 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For supply, installation and commissioning of high-performance liquid chromatography (hplc) under pm usha 1st call
 Loading, Please wait...

Connect us via What's Up