Get complete information related to latest Hinges Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hinges Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hinges Scrap Tenders.
Tender For supply of set of return air duct for wjcc coaches of bangladesh railways., as per drawing: mplradblwjcc version 1, packing instruction: frp ceiling sheet/side wall panels/frp component self adhesive biodegradable plastic lamination sheet to be provided on each component. projected metallic parts to be protected with plastic/nylon/frpcaps/proper wrapping of biodegradable bubble sheet from all the sides. each component to be packed in biodegradable bubble sheet all around with proper tapping & then to be placed incardboard box followed by 3 nylon strips tightened from both sides. then collective packs of components to be packed in wooden cage made from wooden strips of size 100x20mm & gap between each strip should not be more than 100mm.on the wooden crate base 3 wooden pegs of size100x100mm (along the length) to be provided for ease in handling with fork lifter. all loose items of a set to be packed separately in cardboard boxwith list of loose items pasted on each box and collective packs of item to be packed inwooden cage made from wooden . roof ceiling (having curved surfaces) in addition to above packing should be stacked on a metallic frames before packing in the wooden boxes. one package should not contain material belonging to more than one coach set & grouping should be preferably of similar sizes. also packing should have indication like 1/4,2/4 etc. ( e.g. four packings will make one coach set) so that one complete coach set can be easly identified. the maximum weight of the wooden crate should not be more than 200 kgs. a list should be pasted on each wooden crate showing order no, pl no. description of item,drg no/spec no/set list no. with version, qty, firm's name & address,date of despatch etc. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of non ac area ceiling arrangement for lhb executive ac chair car (eog) coaches to drg. no. 1 10113.0.21.420.001, alt-br, anx-1. industrial lock to drg. no.lw44158,alt-d , lw 44318, alt- c and adhesive u bond 301 to be used where ever adhesive is being used. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : repair replacement of internal wiring point wiring and sub main wiring including connected items at zone b otm and md accn at ins rajali under ge m arakkonam - taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed., material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor wire drawn into existing concealed conduit including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :- make of cable : plaza/polycab/finolex/ havells, one light/ fan/ exhaust fan/ buzzer point controlled by one switch., one 3 pin socket outlet 6 amps, independent board with cables 1.5 sqmm size., one 3 pin socket outlet 6 amps,same board with cables 1.5 sqmm size., one light point controlled by two 2- way switches, with cable 1.5 sqmm size., all as per item ser no-2 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size.make :- polycab/finolex/plaza/havells, material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor drawn into pvc conduit and casing & caping fixed on wall/roof/ceiling including wall cutting etc of size not less than 20 mm dia including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :- make for pvc casing & caping: sudhakar / avon plast /plaza , make for copper cable: finolex/polycab / plaza., one light point controlled by one switch., one 3 pin socket outlet 6 amps, indipendent board with cables 1.5 sqmm size., all as per item ser no-4 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size. make :- polycab/finolex/plaza, m&l for sub main wiring for phase and neutral with pvc frls insulated unsheathed multi stranded along with earth wire frls pvc insulted copper conductor, single core cable in and including surface/concealed /pvc conduit appropriate size including cutting chases on brick walls concrete if required/ necessary surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carryiing out the concealed wiring including necessary finishesas specified for the following sizes. make for copper cables: finolex/polycab / plaza/ havells. make of pvc conduit: sudhakar/finolex/avon plast., 2x 1.5 sqmm and 1x 1.5 sqmm as earth wire, 2x 4.0 sqmm and 1x 4.0 sqmm as earth wire, 2x 6.0 sqmm and 1x 6.0 sqmm as earth wire, 2x 10.0 sqmm and 1x 10.0 sqmm as earth wire, 4x 10.0 sqmm and 2x 10.0 sqmm as earth wire, 4x 16.0 sqmm and 2x 16.0 sqmm as earth wire, taking down existing rusted switch board sunken box from site including removing fixtures and fittings such as switch, socket fan regulator complete, removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces necessary plaster, white wash matches with existing colour of wall, floors, etc. all as specified and as directed., supply and fixing in repair of gi metal flush box suitable for mounting moduler plate of following modules:-, 1 or 2 module, 3 module, 4 module, 6 module, 8 module, 12 module, supply and fixing in repair of combined both frame and cover plates fixing on mounting boxes for followin
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For procurement of materials and repairing of pump house, internal wiring at fatepur-i hdtw( ml no 238) mouza, jl no 35, plot no 634, fatepur-ii hdtw( ml no 3) jl no 35, plot no 78 under fatepur mouza, at old malda block, malda. - procurement of materials, c.i. sluice valve with hand wheel, 151marked,15:14846. ) 150 rnrn dia. (sor wrdd ch)13.00 rates of materials for the program 2021-2022 item no-18a) page- 3), 150 mm dia ms plate flange ( rate approved by se dated 14.05.2020), repairing of pump house, stripping off worn out plaster and raking out joints of walls, celings etc. up to any height and in any floor including removing rubbish and stacking anywhere within the compound as directed., dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m in ground floor including roof. (a) up to 150 mm. thick, dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. a) in ground floor including roof, single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand., cement concrete with graded stone ballast (40 mm size) excluding shuttering in ground floor. (a) pakur variety a) 1:3:6 proportion, hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood plank of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (a) 25 mmto 30 mm thick wooden shuttering as per decision and direction of engineer-in charge., reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial strightening and removal of loose rust (if necessary), cutting requisite length, hooking and binding to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) for works in foundation, basement and upto roof of ground floor /upto 4 m. ( i ) tor steel/mild steel. ii. jsw/jspl/shyam/srmb/ bmasl/elecrosteel/ssl, ordinary cement concrete (mix 1:1.5:3) with graded stone chips ( 20 mm down ) excluding shuttering and reinforcement. if any,in ground floor. as per is 456-2000. a) pakur variety (rate analysis), plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary (ground floor)(b) with (1:4) cement mortar. (ii) 15 mm thick plaster, neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc., artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners and including application of cement slurry before flooring works, using cement @ 1.75 kg/sq.m all complete including all materials and labour. in ground floor. 3 mm thick topping (high polishing grinding on this item is not permited) with ordinary cement. (iii) 25 mm thick, applying interior grade acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive distemper/ acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the eic. (in ground floor)applying interior grade acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive distemper/ acrylic emulsion paint
Tender For corrigendum : supply of set of frp ceiling sheet assemblies for lhb chair car, as per drawing: mplcesljsczac version 2. packing instruction: pi112 ver-2. packing instruction: mcf spi (fur)-001 [ warranty period: 78 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of set of frp ceiling sheet assemblies for lhb chair car, as per drawing: mplcesljsczac version 2. packing instruction: pi112 ver-2. packing instruction: mcf spi (fur)-001 [ warranty period: 78 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of set of roof panels for 3-phase memu/tc coaches. coating type pu paint system to mdts-118,colour shade to ral-9001,matt finish gloss value 10-12 at 45degree,ventilator duct grill to ral ds 240 70 05 as per lno.md22151 dated 18.06.19 & 09.07.19. as per design office l.no. md21896 dated 03/10/2022 mdts-133 rev. 05 is applicable in lieu of icf/md/spec-167a mentioned in the drawings as per set list no-: mcfmprp3-phtc version 0. colour shade ral-9001 with matt finish gloss value 10-12 at 60 degree for frp ceiling panels however colour shade for roof ventilator shall be ral ds 240 70 05. packing instruction no.pi112 ver2.0. [ warranty period: 78 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of vestibule ceiling mounting for lhb ac hot buffet coaches., as per drawing: lh44157 alt-g, colour shade of hpl sheet may be ral-ds-9000, packing instruction: - pi019 ver1.0 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of sitc of ceiling mounted ductable type split ac units as per clause 16 schedule of quantities sl no 1 of atc , dummy line item 2 sellers no need to quote for this line item , dummy line item 3 sellers no need to quote for this line item , dummy line 4 item sellers no need to quote for this line item , dummy line item 5 sellers no need to quote for this line item