Get complete information related to latest Hoods Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hoods Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hoods Tenders.
Tender For supply, installation and commissioning of rlp toughened float glass fume hoods for laboratory with cupboard as per attached technical specification, annexure-b. [ warranty period: 30 months afterthe date of delivery ] ]
Tender For supply of 24101c 860mm dia astm516 casing side duct suction eye , 24101c 860mm dia inlet silencer moc ms , 24101c 860mm dia astm filter casing with ss rain hood , 24101c 400 mm dia semi circular damper 860mm dia fan moc astm and ss , 24101c singel blade damper 860mm dia fan moc astm and ss , 24101c aluminium coupling guard 860mm dia fan , 24101c ms igv damper support foor 860mm dia fan , 24101c ss extension arm for 860mm dia fan
Tender For fabrication and replacement of damaged mother plates, hoods, skirt boards, liner plates and deflector plates in various chutes available in mmsd-iii of chp/dr mvr rtpp for the period from the date of issue of loi to 30.09.2026
Tender For miscellaneous items for hpb and liver transplant surgery ot - radiopaque gauze :-should be sterile gauze & made up of 100% cotton gauze fabric type ep 17- x ray detachable should be weaved x ray 100% barium sulphate or metal it should be lint free, non irritating, latex free, and tissue size:- 10*10 cm*12 ply lint free non pack size 1*4 pc., vircyl sutupac 1, 1-0, 2-0 ,3-0 ,4-0, cautery pincil size 9 , electro surgical cautery tip cleaner, micro suction tip canula, liver biopsy gun, c. arm camera cover, usg prob cabel and camera cover, trolley covers, mayo trolley covers, pounch- opsite drap pouch drape:- 2 incise film provides continuous broad-spectrum antimicrobial activity to help reduce the risk of surgical site contamination incise drape adheres to the operative site, creating a sterile surface at the beginning of surgery 360-degree pouch provides optimal fluid collection to minimize contact with fluid and helps reduce the risk of contamination to or team pouch allows for easy clean-up and saves time comes with tube and cord organizers. a clear, plastic, 360-degree fluid collection pouch with tube and cord organizers. size 30*30 cm, steridrip (basic surgical pack), inj. methylene blue 1.0% 10ml ampoule, inj. albumin 5% (100ml), inj. calcium chloride (100 mg/ml), inj. diltiazem (5 mg/1ml, inj. phenylephrine (10mg/1ml) in ampoule size, inj. dns 500ml (double layered sterile plastic polybag), inj. dns 500 ml ( in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), 0.33 ns (double layered sterile plastic polybag), 0.33 dns (double layered sterile plastic polybag), 3% ns (double layered sterile plastic polybag), inj gelofusion 500ml, single arterial & cvp pressure transducer ( compatible with edwards continuous cardiac output monitor ) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 2 three way stopcocks it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern. it should have a flow rate of 3 +/- 1 ml/hr under 300 mm hg iv bag pressure. should be usfda approved., arterial catheter 3fr-l-8cm usfda approved, gamjee roll, ky jelly, l-70 for fluid warmer set, d1-100 tubings for rapid fluid transfusion, hd catheter (size : 11.5 | 8.5 | 9 | 9.5 |10 | 10.5 ), et tube with suction port (size : 7 | 7.5 | 8 | 8.5), single pressure transducer with closed blood sampling system adult(vamp kit) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 1 shutoff valve, 60 patient pressure tubing along with inbuilt inline 12 cc reservoir & 2 self-sealing z-site sampling ports located 13 and 55 from patient for closed blood sampling; pole mountable. it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern, patient dress anti-bacterial ,anti-virus and anti-fungi :- fabric should be effective against bacteria , viruses, fungi, absorbency factor of less than 1 sec as per aatcc-79.has moisture wicking factor of 5 sec as per aatcc 197, fabric made up of 94% polyester ,6% spandex and 180 gsm +/-5% , free from toxin substances , breathable , skin friendly, antiseptic property ,should be iso 13485, cdsco & ce approved. size :- small to xl, pressure
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For auction sale of depot ferrous scrap - cond. and u/s ferrous fabricated materials of ms/ci scrap in nature such as weld mesh, ms duct, anti slip arrangement, earthen bond, galvanized (gi) sheet, ms sheet of various sorts and sizes, blower rotary forging, liner, guide fixtures, side frame fixtures, trolley of various sorts and sizes, trolley wheel & frame, battery fixing iron tray, ms pipe, coach/wagon stand, conveyor belt, ferrous body of auto change over panel, wire mesh, emu coach cut parts, ferrous portion of cab window assembly, sign on iron stand,castiron tems,girder base with concrete adhearings,gearset,grill,vcb panel boxes,gipipes,nuts and bolts,angles,rails,panel boxes,fissureplates,wheels,cupboard, structural items, different type of packing channels, trolley, lat, coach cut up parts, head stock, ms tank, grill gate, rolling shutter,wheel with plate, bins,regulator empty box, dolley, fob fencing, corrugated sheets, rectangular square tube &galvanised sheets, bogie mounted brake beam,brake blocks, gi sheets, pipe,square &rectangular tubes,stair case and handle,ferrous body of various types of motor, angle and channel fabricated with nut, bolt with or without brick and concrete,ladder,plate,grill, barricade, bolts, nuts, tray under frame, cut rod, rails of various sorts and sizes with/without concrete/brick/mud adhering,cut rails or rails used in support structures, coach head stock, coach parts,battery tray, ladder, all types of trolley wheels with minor nfs attachments, screens, channel post, sheets, stand, track machine cut up parts, ms pipes covered with or without rope &with or without parts of rubber, dome, vrla rack, vcb in dismantled condition, vrla battery box & clamp, stand, dtmf way station equipment box, led line display board, hydraulic lifting table with available fittings, vrla battery empty container, bed/base plate, fabricated cut rods,gi pipes, ci pipes and fittings, ms plate, roofsheets, angle, plate, platform bench, spring plank, clamps, cabinet, ms grill, sheets, ladder, steel gate, trolley,ms water tank, fire tender tank,roof truss supporting columns,purlins, sand box, fencing, tl rod, vcb panel, train display board, battery stand, boards, tools box, empty regulator &empty battery container, cut rod, ticket punching cut parts, hand rail, fabricated post/pipe/rod, strips, hoods, impellor, base plates, meshes, battery box frame, grs box, control panel, fan down rod, ac window covers ,angle / channels with/without rails, angle of tld, rack, lt panels, ferrous electrical panel boxes,i beam,transmission rods,fissure plates, main switch panel board w/o nfs attachments, ebc & rbc frame &enclosure,emu sliding door, high beam, silencer, , garden light post, tap changer cover with fiber attachments, empty battery container, stretcher, cupboard, dust bin, iron step, empty rotary junction box, empty regulator box, iron metal box, air reserviour compressor cylinder of varous sorts & sizes, garden light post, stand, mdb w/o non ferrous attachments, st light tubular post, gi/ms window, luggage rack, ,bed portion of weighing scale l with or without any minor non-ferrous attachments and all other scrap excluding ms hand hold in fabricated nature of sorts and sizes full/broken with/without other fs/ci/gi fittings in as is where is condition.pl no 98050126. note:(1) cutting is permitted to loadable size and for heavy nature items only. 2) during delivery if any major non-ferrous items found the same may be handed over to custodian. 3) jcb/crane loading permitted. location: (1)behind a row bin 3&4, (2)near old e-ii ward annexe
Tender For erection and fabrication work a c c - mill mein lage scraper hetu discharge chute ke jo bhag kamzor evam kat gaye hain. unhe kaatkar hatana tatha nai 12 mm ki plate se taiyar kar punah sthapit karna. sath hi scraper ko baandhne hetu profile ke anusar hole wali plate lagakar/welding karke fix karna evam karya poorn hone ke pashchat trial dena. , cane carrier ke gale/ghise runner base ko kaat kar hatana. 100 mm ke channel se box banakar runner base ko lagana evam fit karna va purane channel ko nikal kar seedha karke palat kar lagana. , cane unloader ke purane ghise/kate 40/50 mm size ke sq. bar ko kaat kar hatana tatha yathasthan poorv ki bhanti naye sq. bar ko lagana evam santoshjanak trial dena. , cane carrier/rake carrier/bagasse elevator/r.b.c. ke ghise/kate runner ko kaatkar hatana. uske sthan par purane ko palat kar athva naye runner ko poorvanusar lagana. , cane carrier/rake carrier/r.b.c. ityadi chains ke side ki kati/ghisi/kamzor plate ko kaatkar hatana. uske sthan par purani athva nai plate ko lagana. , fibrizer hood ki side ki ghisi/kamzor plates ko kaatkar nikalna tatha yathasthan nai plate ko lagakar andar va bahar se welding kar santoshjanak trial dena. , bagasse baling machine ki sampoorn overhauling. testing evam trial dena. , s.r.c./i.r.c. ki purani racks ki vanchhit marammat karna. , bagasse elevator/r.b.c. ki chains ki nai racks sample anusar taiyar karna. , t.r.p.f. ke gale/kamzor bottom/top cover ko badalne ke liye naye cover poorvanusar banakar lagana evam santoshjanak trial dena. , s.r.c./i.r.c. ke gale/kamzor tail end boots ko kaatkar hatana tatha sample anusar 8.0/10.0 mm moti purani/nai plate se taiyar kar lagana evam leak.proof welding kar santoshjanak trial dena. , cane unloaders ke panjon ke vibhinn parts ko dismantle karna. dismantle kiye gaye grabs ke sabhi parts ki vanchhit marammat karna. fingers par nirdeshanusar hardfacing kar panjon ka punah assembly karna. , mills ke compound imbibition hetu lagi juice tray mein se gali/kamzor juice tray ko kaatkar hatana. nai plate se sample anusar taiyar kar yathasthan lagana evam samast connection karna. , cane carrier/s.r.c./i.r.c. tatha bagasse elevator chains ko upar uthne se rokne ke liye lagi hui guides mein se ghisi/kamzor guides ko kaatkar hatana. nirdeshanusar nai guide taiyar kar yathasthan lagakar santoshjanak trial dena. , cane unloaders ke bridge/trolley drive ke ghise/kate wheels ko nirdeshanusar welding karna. , t.r.p.f. ke gale/kamzor donali chutes ko kaatkar hatana tatha purane anusar naye donali chute fabricate kar yathasthan erection karna. , cane carrier ke liye lagi idler wheel par nirdeshanusar m.s. ke ring fabricate kar lagana. , mill head stock evam t.r.p.f. head stock ke beech nirdeshanusar 25.0 mm plate se support banakar lagana. , fibrizer ke purane hammer shanks ko nirdeshanusar welding evam hardfacing kar marammat karna evam balance karna. , cane chopper/leveller ke gale hue/kamzor hoods ko kaatkar hatana tatha nai plate se naya folding type banakar lagana. , fibrizer ke pocketed type anvil plate ki pockets ki tooti plates ko nai plates se badalna. mudi hui plates ko seedha karna tatha welding kar taiyar karke nirdeshanusar hardfacing karna. , cane leveller/chopper ke rotor assembly ki ghisi hubbo ke working side evam top sides ko welding kar samatal karna evam nirdeshanusar hardfacing karna. , cane unloaders par lage reduction gear evam motors ke kamzor beds ko kaatkar naye modify karke naye bed banakar lagana tatha gear evam motor ka alignment kar trial dena. , cane carrier ki structure ke gale/kamzor columns ko nirdeshanusar plate lagakar welding kar majbooti pradan karna. , mill rollers mein sample anusar juice ring fabricate kar fit karna. , t.r.p.f. evam mill ke beech mein lage pressure chutes ki vanchhit marammat karna. , mills ke gale/kamzor juice receiving tank ko kaatkar hatana. 8.0/10.0 mm moti plate se sample anusar tank fabricate kar yathasthan fit karna evam samast connection kar leak.proof trial dena. , mill ke ju