Get complete information related to latest Hot Air Dryer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hot Air Dryer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hot Air Dryer Tenders.
Tender For supply, installation, testing & commissioning of set of electrically heated trolley type air baking oven heating load 60 kw with accessories, as per annexure-a attached. the supplier shall give warranty 24 months from the commissioning . acceptable make : shanti (india), jogeshwari, jhalani only.
Tender For consultancy services for preparation of architectural, structural, sanitary, electrical, mechanical, heating, ventilation and air conditioning (hvac) designs/drawings, detailed project reports (dprs), estimates and allied consultancy services for bu
Tender For corrigendum : supply of various types of tools & tackles and miscellaneous items for day to day maintenance works for tmd-ii gtps. - fevi kwik tube 3 grams, anabond rtv silicone 666, packing : 100 gms. for gasket sealing, metal cutting wheel (for stainless steel) size 105 x 1.2 x 16 mm., grinding disc (wheel) size 100x4x16 mm, mos 13750 high cut (a.36) ., mini angle grinder 100 mm, rust removing spray wd-40 in aersole packing of high pressure valves ., pipe vice no.6 size 12 mm to 150 mm, bench vice apex make -150 mm (6"), bench vice apex make -200 mm (8"), gi nipple 15 mmx4 long for civil work, gi nipple 1/2" x 2" long for civil work, gi nipple 1/2" x 3" long for civil work, washing powder ( 1 kg pack ), instametal (0.5 kg/pack), grinding stone (smooth) for 6"(dia.) bench grinder wolf., grinding stone (rough) for 6" bench grinder wolf, pipe wrench size 18" (450 mm) length, heavy duty pipe wrench size:24", heavy duty pipe wrench, length -200 mm, least max opening-33 mm, taparia product no- hpw 08, heavy duty pipe wrench, length -250 mm, least max opening-48 mm, taparia product no- hpw 10, white welding glass size 3.1/4"x4.1/4", atharmal (gremany) make dark green welding glass size:4 1/4x3 1/4 shed 11a 1 din, two stage two gauge oxygen gas pressure regulator - model no : dura 0-10 - esab make, two stage two gauge acetylene gas pressure regulator model : dura a-1.5 - esab make, welding electrode holder fully insulated 600 amp. current (hc 600) , make-esab., esab earthing clamp, cutogen-5 cutting blow pipe (cutting torch), esab/iol make gas heating torch, oxygen gas hose pipe blue 08 mm, make esab/dura., acetylene gas hose pipe red 08 mm, make esab/dura, cutting nozzle size 1/16", cutting nozzle size 3/64", needle file set jk make, taparia chisel 10" long, taparia flat chiesel 1046 150 mm length, hole punch set having 4 to 32 mm dia size, araldite 180 gram/tube, nylon braided pvc hose pipe suitable air/water handling ;at working pressure of 10kg/cm2 size-20mm, nylon braided pvc hose pipe suitable air/water handling ;at working pressure of 10kg/cm2 ,size; 12mm, nylon braided pvc hose pipe suitable air/water handling ;at working pressure of 15kg/cm2 ,size; 25mm id.
Tender For supply, installation, testing & commissioning of 60 kva, 3-phase, 750v/415v dry-type railwaytransformer with class h copper winding, air-cooled (an), vector group yy0, make: mb & company, complete with heating/dry-out and all required tests (ir, hv, ratio, vector group), suitable for lhb coach, complete in all respects as per rdso specification. [ warranty period: 30 months after the date of delivery ] ]
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For corrigendum : provision of electrical equipment against ber equipment held on charge of ge i cg goa - taking down existing industrial socket, indoor/outdoor unit of split type acs of any capacity and size with voltage stabiliser etc. contractor will carefully remove the aforesaid equipment from site and deposit to mes store under age e/m goa complete all as specified and directed., taking down old aluminium/copper sub main wiring of any type and capacity incl. all accessories and all as directed. note : (i) old dismantled wiring and accessories will be contractors property and credit will be charged against schedule of credit., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 1.5 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make: voltas, lg, bluestar, hitachi., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 2.0 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make : voltas, lg, bluestar, hitachi., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 4 kva. make: v-guard, luminious, microtek., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 5 kva. make: v-guard, luminious, microtek., m & l for sub main wiring with two runs of single core 4 sqmm frls copper conductor pvc insulated unsheathed cable as per is 694-1990 (third revision) drawn through & incl casing and caping of suitable size with all accessories such as tees, elbows,couplings, junction boxes etc, as required fixed on wall along with one run of 4 sqmm single core frls insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. note : (i) two runs of phase & neutral wire, one run of earth continuity conductor cable and one run of casing & capping will be measured as one unit for payment purpose.(ii) the wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads., s & f single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole c series mcb 20 amps complete all as specified., supply and fix refrigerators not less than 310 litres, electric driven (single phase), bee 5 star rate with the following features i.e frost free, double door, auto defrost to stop ice builtup, adjustable temperature controller, double door with separate compartment for freezer inverter type compressor with energy efficiency of 5 star rating, tuffened glass shelf complete with an overall product warranty of one year & 10 year on compressor complete including all as specified and directed. note - old removed item shall be deposited in mes store., supply and fix electric water heater, storage type fibre body with copper heating element upto 2 kw capacity 25 litre, bee 5 star rated complete with all accessories such as safety valve, thermostate, nrv, pvc connection pipe and plug top 15 amps etc. including taking out unserviceable one complete all as specified and directed. note - old removed geyser shall be deposited in mes store. make orient cat