Web Analytics Made Easy - StatCounter

Hot Water Generator Tenders

Get complete information related to latest Hot Water Generator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hot Water Generator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hot Water Generator Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45729034 Due date: 27 Jul, 202627 Jul, 2026 87.25 Lacs
Tender For cwek/t-34/864 ews/2026-27 provn of hot water generator for certain bldgs at bb cantt, srinagar in the aor of age e/m and age b/r-iii under ge 864 ews

Central Government/Public Sector

CTN :45716214 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For providing of customized annual maintenance contract/cmc for pre-owned products - non-comprehensive amc of 40 cu.mtr, hot, cold & humidity chamber (make: cm enviro, model: macro-40k-b-h-3k, sl.no:, 120535) located at bahadur/navigation building at hal, hyderabad as pergiven specifications and terms & conditions for period of two years. omc quantity: 8 qtr, controller modular csmstrv2 part code: el060551t2 quantity:1 number, heater cartridge (2000w) part code: el070251t1v2 30l200k2, quantity:10 numbers, controller hmi g07c0000 part code: el0603s1t1v2 4 quantity:1 numbers, single phase preventor k8ak-pm2 part code: el0501s1t1v4 15ph1ti1 quantity:2 numbers, inactive controller ppi omnix partcode: el0604s1t2m7 ri1 quantity:1 numbers, sensor pt100 75x3mm 10m cable partcode: el0401s1t1m1 l75d3cl10 quantity:5 numbers, oil separator helical 1 3/8" o. d.s. sn-5290-ce partcode: rf040254t2pr 31d13/8 quantity:1 numbers, power supply (230vac, 24vdc, 5a) part code: el1102s1t1a5i 230024 quantity:2 numbers

CTN :45516668 Due date: 01 Jul, 202601 Jul, 2026 6.48 Lacs
Tender For corrigendum : supply and erection of 5 kw hot water generator with all electrical connection water flow rate 15 lpw water temperature in 15b degrees , supply and erection of 4 row hot water coil suitable fitted in existing ahu complete , supply and fixing of ss 304 insulated drain tray complete all as specified , supply and fixing o6 kw heater bank with control system fitted in existing including cable and starter complete all as specified , generator heater bank commissioning charges including cabling and stsrter complete all as specified

CTN :45647762 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For supply of spare for generator transformer & cooling water system - winding temeperature transmitter, dual output: 4-20ma, 90-260v ac/dc, precimeasure , current converter unit ccu18, input-pt100 rtd, output: 4-20ma dc,90-260v ac/dc , digital winding temp. remote indicator, range-0-150°c, model no. 2245.t2, precimeasure , digital oil temp. indicator remote, range-o-150°c, model no. 2245.t2, precimeasure , mcb breaker 4 poles, 10a, 10ka, c-curve, 415v ac, siemens , mcb, 6a, 2 pole, 10ka, c-curve, 240vac, siemens , mcb, 16a, 2 pole, 10ka, c-curve, 2 40vac, siemens , mcb, 2a, 1p, 10ka, c-curve, 240v ac, siemens , mcb 10a, 1p, 10ka, c-curve, 240v ac, siemens , mcb, 6a, 2pole, 10ka, c-curve, 110v, ac, siemens , moulded case ckt breaker (mccb) 32a, 55ka, 4pole, 415v ac, siemens , power contactor, 4 poles, 415vac, 12a, 415v with add on 2no+2nc (aux. supply 110v ac)3tf31-10-0a , aux. contactor (ac supervision), 110v ac, 2no +2nc,3th30-22-0a , aux. contactor, 110v ac, 3no+1nc with add-on aux. contact block 2no+1nc,3th30-31-0a , motor thermal overload relay (4-6.3a),3ua50 001g , relay used in the cooler control circuit (minilec) minilec d1hls1 , time delay relay, 110v, 0.1-10h with 2 c/o contact, micon 2a5dt5 , selector switch 2 way with off, 6a, 240v 2 pole, type: s10-61025-bb, make: l&t/kaycee , selector switch, 10a, 440v, 2 ways with off 4 pole, make: l&t/kaycee , selector switch, 2way on off,10a, 440v, 10 pole , auxiliary transformer, 415v/55-0-55 (110v), 500va, make: l&t/kaycee , led (red, green) for pump on indicator suitable, 110v ac , differential pressure gauge (fiebig) 0-1.5 kg/cm 2 above to 380v 30w 50va , water leakage detector sapcon probe length 68mm , resistance temp. detector (rtd) for (wti and oti), pt 100, precimenasure , pump main & stan - by selector switch, , nylonwasher size 2.5tkx4 id x8 od , generator , carbon brush (50.8x38.1x25.4) mm, hm6 grd , brush holder , slip ring assembly (refer annexure-10) , insulation stud with epoxy with fire , retardant, shaft l= 315 from flange face, ø55, flange l 150, width 90, flange thickness 20, hole ø18, hole spacing(l) 108, hole spacing (w) 46 measurements in mm , duplex rtd pt/100 l-930, b-630, h 370 (mm) , dail type thermometer (dtt)l=35 m,.length of bulb--100mm, bulb coneection-standard p.f. 3/4 double union. 5 kg/cm2, type-gas filled, dial siz- 150 mm or 160 mm. accuracy+-2-degree celcus. (refer annexure-1) , thermostat for (guide bearing) , max operating voltage: 220v dc (±10%) , temperature range: 20°c to 100°c , max working temperature: 110°c , capillary tube length: 6 meters , switch action: 1 spdt for alarm and 1 for trip , (at two different temperatures) , differential temperature: 2°c to 5°c , accuracy: ±3°c of set point , repeatability: ±3°c , working temperature: 110°c ((refer annexure-2) , thermostat for lower guide bearing, (spec same as sl, 35) , thermostat for space heater (maximum current capacity: 1 amaximum operating , voltage: 250 vdc ±10%temperature range: 25°c to 90°ccapillary tube length (l): 5 meters switch action: spdtdifferential temperature: 3°c to 5°caccuracy: ±3°c of set pointsetting temperature:75°c for bearing & hot air40°c for heater controlrepeatability: ±3°c (refer annexure-3) , motorised valve, actuator type- k300 g1/g2a, enclosure -wt to ip 68, output speed-36 rpm, max tourque-305nm, motor 1.2 kw, 415v, average load-3.10a and locked rotor, 25a (roterz brand) , gate valve (1/2") brass , hex bolt m12*30 , hex bolt m12*50 , hex bolt m6*20 , hex bolt m16* 68 , stud m12*100 , cooling water system , moulded case circuit breaker (mccb), 500a 3p 50ka 415vac, mccb, with magnetic releases, dsine dn3-630m,500a, make-l&t , copper 220v mnx 550/650 spare coil cat no:cs94193(10 each) co , power contactor, 250a, 3p, power contactor with 240v ac coil, aux 2no+2nc contacts, mnx250, make-l&t latch relay, latch relay with 3no+1nc, 240vac coil aux supply with mechnical interlock electrical reset , aux contactor, auxilary contactor

Central Government/Public Sector

CTN :45403836 Due date: 30 Jun, 202630 Jun, 2026 50.00 Lacs
Tender For corrigendum : repair maintenance of ac plant infrastructure replacement of defective condenser tubes chiller tubes hot water generator system alongwith other accessories at naval station karanja

State Government

CTN :45612558 Due date: 01 Jul, 202601 Jul, 2026 16.77 Lacs
Tender For annual rate contract for descaling servicing of hot water generator and heat exchanger etc. at hotel samrat new delhi

Central Government/Public Sector

CTN :45564519 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For design, supply, installation, testing and commissioning (dsitc) of 250 kw hot water generator at bank’s office premises, rbi jammu

State Government

CTN :45542054 Due date: 06 Jul, 202606 Jul, 2026 2.42 Crore
Tender For up gradation of central eating system pf of hot water generators/radiators/fcus along with ms piping and allied works in govt. dental college hospital, srinagar phase 2nd

Central Government/Public Sector

CTN :45529880 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For providing of custom bid for services - cleaning of hot oil heater tubes, clamps replacement,preparation for ndt, insitu metallography & hydrotest of tubes/coils in position & shell repair

State Government

CTN :45531964 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For cleaning of hot oil heater tubes, clamps replacement,preparation for ndt, insitu metallography and hydrotest of tubes, coils in position and shell repair
 Loading, Please wait...

Connect us via What's Up