Tender For corrigendum : items - equipment accessories, abg machine ( as per model , make), 1. all card (as per req), 2. printing papers rolls (as per req), 3. cuvettes (as per req), 4. refill solution 100 ml (as per req), 5. controls, 6. syringe tips, 7. cleaning solution 100 ml, anesthesia machine ( as per model , make), 1. soda lime 5kg , 2. mask, 3. breathing circuits, 4. anesthesia agents, 5. bains circuit, 6. flow sensor, 7. oxygen sensor, 8. isoflurane inhaler 100ml, blood bank refrigerator ( as per model , make), 1. chart paper (as per req), 2. ink cartridge (as per req), 3. refrigerant gas, 4. oil filter, 5. air filter, defibrillator ( as per model , make), 1. pads, 2. jelly 100 gm, 3. paper, 4. leads, 5. battery, 6. bp cuff adult / neonation, 7. disposable electrodes, elisa reader washer ( as per model , make), 1. printing papers rolls (as per req), 2. cuvettes (as per req), 3. refill solution 100 ml (as per req), oxygen concentrator ( as per model , make), 1. o2 tubing (as per req), 2. face masks (as per req), suction machine ( as per model , make), 1. transparent cannula, 2. suction cannula, 3. holder, 4. filter, 5 jaar, 5. tube, x-ray machine ( as per model , make), 1. battery in hf, ventilator ( as per model , make), 1. disposable masks, 2. breathing circuits, 3. hme filter, 4. bacterial filter, 5. oxygen sensor, 6. flow sensor, 7. battery, microscope ( as per model , make), 1. immersion oil, deep freezer, walk in freezer, walk in cold room, walk in cold room, ice lined refrigerator ( as per model , make), 1. chart paper (as per req), 2. ink cartridge (as per req), 3. refrigerant gas, 4. oil filter, 5. air filter, 6. battery, usg machine ( as per model , make), 1. ups batteries, 1. jelly 100 gm, 2. thermal paper roll (as per requirement), autoclave ( as per model , make), 1. printer ribbon and rolls, 2. b & d test pack, 3. biological indicators, 4. water quality should be as per oem recommendations otherwise, 5 heating elements will be consumable., audiometer ( as per model , make), 1. ear tips, 2. electrodes, others items, multipara monitor lead ( as per model , make ), multipara monitor stand ( as per model , make ), multipara monitor prob ( as per model , make ), tabletop pulse oxymeter prob ( as per model , make ), tabletop pulse oxymeter adaptor ( as per model , make ), autoclave biological indicators tape ( as per model , make ), ecg machine lead ( as per model, make), ecg electrodes, nibp cuff (as per model , make ), silicone suction tube per meter, spo2 probe neonatal as per department equipment, spo2 probe pediatric as per department equipment, spo2 probe adult as per department equipment, stethoscope ( adult) dr. morepen, bpl, diamond
Tender For supply of lcd 2d 4k monitor 32 inch , 4k 2d 3d ir video processor , led light source , autoclavable 4k ir camera head , ultra 4k telescopes 10mm 30 degree , light guide cable , high flow co2 gas 45l per min or more insufflator , recording device , trolley , trocar set size 10 to 11mm , trocar set size 5 to 6 mm , bipolar forcep 5 mm 330 mm , maryland grasper 5mm 330 mm , plain grasping forcep 5mm 330 mm , toothed grasping forcep 5mm 330 mm , bowel grasper 5mm 330 mm , trumpet type suction irrigation 10 mm , trumpet type suction irrigation 5 mm , clip applicator with titanium clip 200 , clip applicator with titanium clip 300 , clip applicator with titanium clip, 400 , l hook , curved scissor , monopolar cable , bipolar cable , reducer 10 by 5 , reduction sleeve 10 by 5 , sealing cap for trocars 10 mm to 11 mm 10 pcks , sealing cap for trocars 5 mm to 6 mm 10 pcks , claw forcep 10 mm , claw forcep 5 mm , stone extractor , ovum forcep , aspiration needle , varies needle , laparoscopic needle holder , laparoscopic bab cock forcep , port closer needle , choledochoscope , dejerdin lithotomy forceps
Tender For miscellaneous items for hpb and liver transplant surgery ot - radiopaque gauze :-should be sterile gauze & made up of 100% cotton gauze fabric type ep 17- x ray detachable should be weaved x ray 100% barium sulphate or metal it should be lint free, non irritating, latex free, and tissue size:- 10*10 cm*12 ply lint free non pack size 1*4 pc., vircyl sutupac 1, 1-0, 2-0 ,3-0 ,4-0, cautery pincil size 9 , electro surgical cautery tip cleaner, micro suction tip canula, liver biopsy gun, c. arm camera cover, usg prob cabel and camera cover, trolley covers, mayo trolley covers, pounch- opsite drap pouch drape:- 2 incise film provides continuous broad-spectrum antimicrobial activity to help reduce the risk of surgical site contamination incise drape adheres to the operative site, creating a sterile surface at the beginning of surgery 360-degree pouch provides optimal fluid collection to minimize contact with fluid and helps reduce the risk of contamination to or team pouch allows for easy clean-up and saves time comes with tube and cord organizers. a clear, plastic, 360-degree fluid collection pouch with tube and cord organizers. size 30*30 cm, steridrip (basic surgical pack), inj. methylene blue 1.0% 10ml ampoule, inj. albumin 5% (100ml), inj. calcium chloride (100 mg/ml), inj. diltiazem (5 mg/1ml, inj. phenylephrine (10mg/1ml) in ampoule size, inj. dns 500ml (double layered sterile plastic polybag), inj. dns 500 ml ( in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), 0.33 ns (double layered sterile plastic polybag), 0.33 dns (double layered sterile plastic polybag), 3% ns (double layered sterile plastic polybag), inj gelofusion 500ml, single arterial & cvp pressure transducer ( compatible with edwards continuous cardiac output monitor ) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 2 three way stopcocks it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern. it should have a flow rate of 3 +/- 1 ml/hr under 300 mm hg iv bag pressure. should be usfda approved., arterial catheter 3fr-l-8cm usfda approved, gamjee roll, ky jelly, l-70 for fluid warmer set, d1-100 tubings for rapid fluid transfusion, hd catheter (size : 11.5 | 8.5 | 9 | 9.5 |10 | 10.5 ), et tube with suction port (size : 7 | 7.5 | 8 | 8.5), single pressure transducer with closed blood sampling system adult(vamp kit) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 1 shutoff valve, 60 patient pressure tubing along with inbuilt inline 12 cc reservoir & 2 self-sealing z-site sampling ports located 13 and 55 from patient for closed blood sampling; pole mountable. it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern, patient dress anti-bacterial ,anti-virus and anti-fungi :- fabric should be effective against bacteria , viruses, fungi, absorbency factor of less than 1 sec as per aatcc-79.has moisture wicking factor of 5 sec as per aatcc 197, fabric made up of 94% polyester ,6% spandex and 180 gsm +/-5% , free from toxin substances , breathable , skin friendly, antiseptic property ,should be iso 13485, cdsco & ce approved. size :- small to xl, pressure
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For corrigendum : 4 kw high frequency mobile machine- high capacity electronics oscillating system (5 kva to 100 kva), vitrectomy unit, flow cytometer, solid state photocoagulator, ent powered drill system, iol, hemo diafiltration machine, nct (non contact tonometer), 4 kw high frequency mobile machine, modular monitor, dialysis chair, video endoscope system, disinfectant generation system, fully automated allergy analyzer., body box (plethysmography system), automated plasma expresser., advance visual field analyzer, non contact biometer swept source oct technology., rapid biological indicator for autoclave., laparoscopic simulator.