Get complete information related to latest Hpsv Street Light Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hpsv Street Light Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hpsv Street Light Tenders.
Tender For corrigendum : nit for ntpc sipat station lighting system (turnkey package) - station lighting system for 1 x 800 mw ntpc sipat stpp, stage - iii
Tender For procurement of material and hiring of labour for day to day maintenance of various electrical installations in municipal parks and buildings in ward 140 inderpuri under kbz - supply of 1.5 sq. mm isi marked, frls pvc insulated,single core copper conductor cable as required., supply of 4.0 sq. mm isi marked, fr pvc insulated, single core copper conductor cable as required., supply of 63 amps., 2 pole isolator as required., supply of 6 a, to 32 a, ratings, dp mcb, "c" curve, 10 ka breaking capacity as required., supply of 6a to 32 a ratings, sp mcb, "c" curve, 10 ka breaking capacity as required., supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsvstreetlight fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:- 2x 6 sqmm, supply of xlpe insulated pvc sheathed al. conductor armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*10 sqmm, supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. (c) three phase 5.0 hp having discharge of 300 lpm approx. at 39 m head., providing following labour for day to day maintenance of ward i/c required t&p etc. in one shift in a day on all working days (required maintenance material will be provided by department) as required as per terms & condition of the department (excluding parts) complete as required. 1. skilled labour", providing following labour for day to day maintenance of ward i/c required t&p etc. in one shift in a day on all working days (required maintenance material will be provided by department) as required as per terms & condition of the department (excluding parts) complete as required. 1. un-skilled labour", supply of led streetlight fixture, powder coated pressure die cast aluminium body (system lumen efficacy 120 135 lm/watt) of following body materials. - 45 watt
Tender For re tender lac-ads-open air stage and bus shelter at arakkapady jn vengola gp-lighting of open stadium and bus shelter-general electrical work
Tender For corrigendum : providing audio and video system, stage lighting & stage curtain in nila auditorium at ncess, trivandrum. sh: providing audio & video system.
Tender For construction of 200 capacity auditorium at central staff training and research institute(cstari) campus, en 81,saltlake kolkata 700091 including interior acoustic treatment, external grc elements & art, providing internal electrical installation (iei) power points, lightening conductors, fire alarm system, cctv, audio video system, stage furnishing & stage lighting system. sh: geotechnical/soil investigation at the proposed construction site at cstari during the year 2026-27.
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For renovation work of dr. b.p. pall auditorium, iari pusa, campus, new delhi. (sh: supply, installation, testing and commissioning of stage lighting )
Tender For construction of extension of medical college at aiims bhopal. (supplying & fixing of stage lighting & miscellaneous electrical work in existing auditorium building at aiims bhopal)subwork/packages:supplying & fixing of stage lighting & miscellaneous electrical work in existing auditorium building at aiims bhopal
Tender For supply, installation, testing and commissioning of audio video system along with projection system, stage lighting and motorized curtain system at keshav mahavidyalaya, pitampura, delhi sh supply, installation, testing and commissioning of 19 rack mount antenna, power distribution system and shifting of light control).
Tender For providing of tentage service lumpsum based - inauguration of renovated old light house building - av and arrangements; lighting, furniture & equipment rentals, av - led wall, delay led wall, fly (line-array) audio system, stage lights, podium, generator, furnitur..