Get complete information related to latest Hrc Fuse Base Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hrc Fuse Base Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hrc Fuse Base Tenders.
Tender For supply of high voltage hrcfusebase (holder) suitable for hrcfuse 2amps, 1.2 kv, cylindrical type, size: 8x50 mm used in primary of 200va control transformer of switch board cabinet of lhb ac coaches confirming to 'rdso/pe/spec/ac/0184-2015 (rev.'2) dated 10.02.2026. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of set of spares for ckd make prv items suitable for aal make vcb 1. ckd prv with gauge , input & output bolts with washers, to suit aal vcb, ckd make asper part no. w-2000-10-w-m1. 2. ss input pipe with base plate for ckd prv suitable for aal vcb to m/s solutions automation part no: stap-3/8. 3. air gauge with metal adaptor, used at air tank in panel as per part no: g49d-6-10 p. make: ckd only. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of open type hrcfusebase size-2, rated current 400a to is:13703 part-2/iec-60269-2(latest),with isi mark,cat no.3nh3 330 of siemens or equivalent of ge/c&s/bussman/l&t make only as per drg. no.wgaccn-7-2-002 alt-h [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]
Tender For corrigendum : supply of accessories for cable- (i)piercing connector type-i 16-50, (ii)piercing connector type-ii 16-50, (i)piercing connector type-i for single phase/ three phase (main 70-150 sqmm. tape of 50-95sqmm), (ii)piercing connector type-ii (main 70-150 sqmm tape-of 50-95 sqmm), suspension clamp with attachment, tension clamp with attachment, cable straight-through joint kit suitable for 70 sqmm, cable end termination kit suitable for 70 sqmm, i)t clamp for bus bar for dog to dog conductor, ii)terminal clamp for busbar for panther conductor, bi-metallic clamps for vcb, bi-metallic clamps for transformer, 30v 100ah lead acid battery, battery charger suitable for 30 v 100ah battery, 30v dc lithium-ion battery set, lt robust fuse unit/switch fuse unit, gi pipe 150mm b grade, gi pipe 150mm a grade, heat shrinkable cable jointing kit with lugs for 33/11 kv 3 core (33/11kv, 3*300 sqmm), (i)ht bi-metallic clamps for dtr, (ii)lt bi-metallic clamps for dtr, (i) dc distribution board with mcb, (ii)ac distribution board with mcb, led lamp complete fitting, (i) aluminium lugs 70 sqmm, (ii) aluminium lugs 150 sqmm, (iii) aluminium lugs 300 sqmm, pf unit (kitkat) 200 amp., pf unit (kitkat) 300 amp., hrcfusebase 200/250 amp., hrcfusebase 300 amp., hrcfusebase 400 amp., hrcfuse link 200/250 amp., hrcfuse link 300 amp., hrcfuse link 400 amp, hand operated chain pulley block 3 ton, silica gel breather 500 gm., (i) bi-metallic clamp suitable for 12mm dia lt stud, (ii) bi-metallic clamp suitable for 20mm dia lt stud, (iii) bi-metallic clamp suitable for ht stud, i) i-bolt 20 mm., ii) i-bolt 16 mm., t.c. fuse wire 14,16,18 & 20 swg, ethical & generic medicines and surgical items for dispensary mppkvvcl, ujjain
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp