Web Analytics Made Easy - StatCounter

Hsc Pump Tenders

Get complete information related to latest Hsc Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hsc Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hsc Pump Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45732868 Due date: 03 Jul, 202603 Jul, 2026 2.36 Lacs
Tender For overhauling and re-conditioning of 120hp hsc pump set and induction motor no.03 including replacement of bearing shaft sleeves, casing rings, glands and other minor parts damaged if any with new parts at chennapur pump house, chandrapuri colony ward, keesara circle under eam cell, malkajgiri zone, hmwssb.

Central Government/Public Sector

CTN :45713851 Due date: 25 Jul, 202625 Jul, 2026 55.00 Lacs
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole

State Government

CTN :45737522 Due date: 27 Jul, 202627 Jul, 2026 22.59 Lacs
Tender For supply, erection, testing and commissioning of horizontal split case(hsc) pump complete set

CTN :45715693 Due date: 15 Jul, 202615 Jul, 2026 19.48 Lacs
Tender For tender for supply of erection and fabrication work - pan/quad bodies ki kamzor shell ko kaatkar hatana. 10/12 mm moti plate se taiyar kar yathasthan lagana. andar aur bahar se double coat welding kar leak/proof water/vacuum trial dena. , quad evam pan par lage vapour/steam line mein lage 600/1000 mm dia ke right/angle type vapour valves ko dismantle kar valve ki leak/proof marammat karna evam testing uparant punah yathasthan fit karna. , pan/quad ke vapour pipe ke gale/kamzor vapour pipe bends ko naye fabricate karke badalna 600 mm se 1100 mm dia. , quad evam pan ke vapour pipes. vapour/exhaust steam lines ko majbooti pradan karne ke liye angle iron athva plate se t/rings banakar support dena. , vapour cell. semi/kestner. pan va quad bodies ki purani gali steam jackets ko hatakar nikalna. 10/12 mm plate se naya banakar lagana tatha leak/proof trial dena. , pan. quad. vapour shell adi ka fin type cyclone fit karna. naya 8/10 mm plate se banakar fit karna tatha welding kar santoshjanak trial dena. , quad/pans par sthapit vibhinn steam ke gale/kamzor/leaky valves ko kaatkar/kholkar hatana tatha valve ki vanchhit marammat uparant nirdeshanusar fit karna. , air cooled/dry seed/vacuum/twin vertical crystallizer ki drive ke kshatigrast/ghise hue worm wheels ki gland housings ke bush badalne ke liye worm wheel evam worm shaft housings ko dismantle kar alag karna. gland housings mein naye gun metal bush lag jane par housings ki fitting uparant uplabdh karaye gaye worm wheel evam worm housings ko poorv ki bhanti fit kar alignment karna. , vacuum crystallizer ke shell ke gale/kamzor bhagon ko kaatkar hatana. nai/purani plate se shell modkar yathasthan fit karna. andar aur bahar se leak/proof welding karna tatha bahar se vanchhit strengthening karna. , air/water cooled/vacuum/twin vertical crystallizer ke kshatigrast danton wale worm evam worm wheel ko dismantle kar hatana evam unke sthan par naye worm evam worm wheel fit karna. reduction gear evam motor fit karke alignment karna evam trial dena. , pans/crystallizers par lage vibhinn gutters mein se kamzor gutters ko kaatkar hatana. purani plate se banakar lagana. , air/water cooled crystallizers ki purani/kamzor/tooti hui shaft ko dismantle karna. nai shaft taiyar kar yathasthan lagana evam samast arms lagakar santoshjanak trial dena. , air/water cooled crystallizers ki shaft ke gale/kamzor bhag ko kaatkar hatana. m.s. plate se shaft taiyar kar naye pipe ki shaft yathasthan fit karna evam samast arms poorv ki bhanti lagakar santoshjanak trial dena. , crystallizers ki drive shaft ke dono taraf dheele hue/ghise gun metal bush bearings ko nikalna. naye bush fit kar trial dena. , air/water cooled crystallizer ki shaft par lagi kamzor arms ko kaatkar hatana aur m.s. plate/pipe se nai arms fabricate karke shaft par lagakar sucharu trial dena. , air/water cooled crystallizer ke leaky/kamzor gate valve ko repair karke leak/proof fitting karna. , spray hetu sthapit mf 35x35 spray pumps ke elliptical suction pipes mein se gale/kamzor section pipes ko dismantle kar hatana. 8/10 mm moti m.s. plate se sample anusar may strainer fabricate kar yathasthan fit kar leak/proof trial dena. , quad/pans ke condenser mein lage multi/jet spray boxes ki vanchhit marammat karna. , spray pond ke main header. branch header evam branch lines ke gale/kamzor bhagon ko kaatkar nirdeshanusar nai evam purani plate se taiyar kar yathasthan fit kar leak/proof trial dena. , common injection header ke kamzor bhag ko kaatkar hatana. naya fabricate kar yathasthan erection kar leak/proof trial dena. , injection. spray pump ki drive motor ke gale/kamzor resistance box taiyar karna. sabhi internals fit karna. connection kar santoshjanak trial dena. , vertical spray pump ke gale/kamzor base frame ko dismantle karna. poorv ke anusar naya bed fabricate kar level karke yathasthan lagana evam pump fit kar alignment kar dena. , pans ke gale/kamzor feed distribution headers ko kaatkar hatana tatha unke sthan par nirdeshanusar m.s. plate

CTN :45520010 Due date: 06 Jul, 202606 Jul, 2026 37.98 Lacs
Tender For corrigendum : supply, installation, testing & commissioning of 700 kw, 989 rpm, 6.6 kv ht 3-phase induction motor compatible to existing base frame of wilo make hscf pump installation with suitable coupling & other required accessories including insurance, transportation, loading, unloading, inspection charges etc. complete for nc-6, khirai pumping station, tal-maliya, dist-morbi

CTN :45707130 Due date: 17 Jul, 202617 Jul, 2026 1.35 Crore
Tender For supply of jyoti make spares of vt and hscf pump for modhera, motidav and rasalpur pumping stations of modhera-dharoi pipe line project.(with buyback). - top shaft with sleeve, line shaft no.1 with sleeve, line shaft no.1 with sleeve, impiler shaft with sleeve, impiler shaft sleeve, impelier wear ring (de+nde), bering housing for thordon bearing, muff coupling, bering no-de, bering no-nde, providing spares for vt pump make: jyoti, serial n27943,n27946 & n27947, capacity: 3400 m3/hr., head - 96 m, rmp-960, l.p.m. 56667, type: 500hs style : ip419-145 with buy back sat motidav pumping station for modhera-dharoi pipeline project., top pump shaft, pump shaft sleeve, impeller wear ring ( de+nde), gunmetal bush ( rubber bush with sleeve coupling), bering no-de, bering no-nde, providing spares for vt pump make: jyoti, serial n27936,n27337, n27939 & n27940, capacity: 5100 m3/hr., head - 56 m, rmp-992, l.p.m. 85000, type: 600hs style : ip419-146 with buy back sat rasalpur pumping station for modhera-dharoi pipeline project., top pump shaft, pump shaft sleeve, impeller wear ring ( de+nde), gunmetal bush ( rubber bush with sleeve coupling), bering no-de, bering no-nde

corporations/Associations/Others

CTN :45720480 Due date: 08 Jul, 202608 Jul, 2026 2.00 Lacs
Tender For repair works to 50 hp hsc pumpset unit no i and allied works at kombupallam head works

State Government

CTN :45707316 Due date: 13 Jul, 202613 Jul, 2026 14.14 Lacs
Tender For supply, installation, testing and commissioning of hscf pumping machinery with associated mechanical and electrical equipment and accessories @ gorad esr in valli pumping station, under milrampura gorad rwss district: anand

State Government

CTN :45649131 Due date: 23 Jun, 202623 Jun, 2026 49.35 Lacs
Tender For supply, delivery and fixing of 100 hp hscc pump set to discharge 220m3/hr. at head of 80mtr along with panel board, cables, suction pipe line and accessories at sayednagar pump house asifnagar filter beds under eam section, sub div. no ii,transmission division i.

CTN :45622736 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of pump shaft of material carbon steel (part no-180) for 100000 gph hscf pump(kirloskar) , model no-dsm 150/46 [ warranty period: 30 months after the date of delivery ] ]
 Loading, Please wait...

Connect us via What's Up