Get complete information related to latest Ht Switchgear Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ht Switchgear Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ht Switchgear Tenders.
Tender For repairs and replacement of lt panel and lt ug cable poles and htswitchgears including earthing at coimbatore and madukkarai area under ge wellington
Tender For supply of design and supply of 11kv,3 phase,50 hz,630a bus bar 4panel,250 mva, indoor type htswitchgear consisting of vacuum circuit breakers,bus bars,pt,ct,mfms,protective relays,cable glands,trickle charger,insurance , transportation and unloading at site of the switchgear,installation, including civil foundation, consumable hardware and other accessories,testing and commissioning of the above htswitchgear,complete installation material for the above switchgear,charges for getting cea and state electricity board clearance for complete switchgear installation,special tools if any required for field maintenance and repair of vcbs list of tools to be enclosed,book of instruction for installation with finalized drawing
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh
Tender For corrigendum : supply of spares for lnt make lt and htswitchgear breakers and panel accessories of electrical circle and chp circle, csctpp, chhabra
Tender For electrical works - works under the 'business plan 2026-27' head—specifically comprising 33 kv vcbs, 33 kv switchyards, 11 kv switchgear, and the strengthening and protection of 33/11 kv substations—to be executed within the jurisdiction of the urban electricity distribution division (33 kv), trans-hindon area, ghaziabad, under the administrative control of the urban electricity distribution circle (commercial & technical), ghaziabad.
Tender For work for shifting of electrical equipments from old crb to new crb and construction of new crb with boundary wall and other related civil work at raninagar ss switch yard under domkal division wbsedcl - dismantling of existing rtcc pnl from old crb and re-installation the same tyo new crb., removal of existing 1.1kv 4c x 2.5 sq. mm copper control cable from existing cable trenches and relaying the same to new cable trenches with all complete., removal of existing 1.1kv 8c x 2.5 sq. mm copper control cable from existing cable trenches and relaying the same to new cable trenches with all complete., removal of existing 1.1kv 12c x 2.5 sq. mm copper control cable from existing cable trenches and relaying the same to new cable trenches with all complete., re-installation of 30v,100 ah battery from existing crb to new crb, re-installation of 30v, 35 a automatic float cum boost battery charger from existing crb to new crb., re-installation of ac 3-phase 4w (1a) ct/pt operated amr. tri-vector 33 kv feeder meter from old crb to new crb., re- installation of a.c. 3 phase, 3w ct/pt operated amr. tri-vector 11 kv feeder meter from old crb to new crb, re-arranging for installation of data communication system including hardwares & cable with telephone modem, mri for all meters for 33/11kv sub-station having features for lan and remote connectivity along with supply of materials., relaying & dressing of existing healthy portion of 11 kv 3c, 300 sq mm xlpe cable in the new cable trenches., laying of 1.1 kv 185 sq. mm 4c , pvc cable., laying of 1.1 kv 120 sq. mm 4c , xlpe cable., laying of 1.1 kv 50 sq. mm 4c , pvc cable., laying of 1.1 kv 25 sq. mm 4c , pvc cable., laying of 1.1 kv 16 sq. mm 2c , pvc cable., laying of 1.1 kv 10 sq. mm 2c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 185 sq. mm 4c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 120 sq. mm 4c , xlpe cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 50 sq. mm 4c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 25 sq. mm 4c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 16 sq. mm 2c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 10 sq. mm 2c , pvc cable., re-installation of a.c. switch board from old crb to new crb., re-installation of d.c. switch board from old crb to new crb., dismantling of existing switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 4 panel (1in +0bc+3out) from old crb and re-installation the same to new crb., erection of switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 8 panel (2in +1bc+5out)., erection of switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 1 panel (0in +1bc+0out) (one buscoupler pnl along with adaptor), dismantling of existing switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 3 panel (1in +0bc+2out) from old crb and return to store in good condition., dismantling of existing switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 4 panel (1in +1bc+2out) from old crb and return to store in good condition., removal/uprooting & returning of different size of 1.1 kv pvc cable. qty taken l.s amount as not submitted by site office in the list of returnable materials)