Get complete information related to latest Hub Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hub Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hub Switch Tenders.
Tender For providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above supplied stab
Tender For supply of spares for prabhu make ht starter pac bid - isolator 400 amp 3 point 3 kv on off part no ht100 , isolator fixed contact set part no ht1001 , isolator moving contact set part no ht1002 , vacuum contactor 400 amps 3 point 3 kv part no ht200 , vacuum contactor rectifier bridge part no ht201 , vacuum contactor closing coil 110v dc part no ht203 , vacuum contactor holding coil 110v dc part no ht204 , auxiliary switch for vacuum contactor 2n part no ht205 , p t 40va 0 8 12v 0 110v part no ht206 , auxiliary contactor 3no plus 1nc 110v part no ht208 , resin cast p t 750va 3 point 3kv 110 volt part no ht300 , ht control fuse 3 point 3kv 2mps part no ht400 , resin cast moulded ct for o l relay 75 part no ht600 , resin cast moulded ct for ammeter 150 5 part no ht650 , dmc moulded 3 point 3kv insulator for power fu part no ht700 , earth leakage relay unit complete witho part no ht800 , 3 pole magnetic o l relay part no ht900 , o l rly thrml 4 7 point 5 a ct oprtd w mntng part no 900b , 72sq mm ammeter 0 150 450a part no ht1000 , 72sq mm voltmeter 0 5kv part no ht1100 , ammeter selector switch part no 1001 , hrc fuse base and carrier for control part no ht1200 , hrc fuse link for control part no ht1201 , push button with element for start sto part no ht1300 , lamp holder with lamp on off trip part no ht1400 , power hrc fuse part no ht1500 , brass cable gland complete with ci clam part no 1600 , cable box complete w o gland for i c t part no 1600a , terminal chamber for i c t g o g and pa part no 1600b , isolator handle on off with axel bush part no 1501 , isolator limit switch part no ht1700 , single phasing preventor with module part no ht2001 , static type idmtl over current and short part no ht900a , voltmeter selector wsitch part no ht1101 , contactor tp 12 amps ac3 duty fitted wit part no ht200a , diode by255 for vacuum contactor part no ht200c , copper bus bar 400 amps set of 3 part no ht101 , pilot realy 12dc part no ht2200