Get complete information related to latest Humidifier Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Humidifier Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Humidifier Tenders.
Tender For supply of air purifier, rated voltage: 220-240v, rated frequency: 50/60 hz, rated power: 85w, noise( high speed): 59db/a, noise (low speed) : 38. odb/a, anion concentration: 10 million/cm3, amount particute cleaned air ( cadr)2: 101.6m3/h, applicable area 2: 1008 square feet/ 93 square meters, suggested period to replace filters 1: pre filter and humidifier filter life up to 2 years compound filter 1: anti-bacterial filters, silver ion and h13 filters life upto 9000 hrs or 1 year, compound filter 2: cold catalyst filter and activated carbon filters life upto 9000 hrs or 1 year, net weight: 11.3 kg, product measurement : l400xw230xh640mm, components: pre filter and humidifier, compound filter1: anti-bacterial filters, silver ion and h13 filters, compound filter 2: cold catalyst filter and activated carbon filters, fan speed :1-8, alexa-enabled, air quality display: yes, filter rest indicator: yes, 4color air quality indicator : yes, wi-fi & smart app control : yes, filters life : 9000hrs upto 1 years, uv : led, child lock button : yes, sleep mode : with 1-12 hr automatic shut- off time, warranty : 2 years onsite. [ warranty period: 24 months after the date of delivery ] ]
Tender For corrigendum : supply of air purifier, rated voltage: 220-240v, rated frequency: 50/60 hz, rated power: 85w, noise( high speed): 59db/a, noise (low speed) : 38. odb/a, anion concentration: 10 million/cm3, amount particute cleaned air ( cadr)2: 101.6m3/h, applicable area 2: 1008 square feet/ 93 square meters, suggested period to replace filters 1: pre filter and humidifier filter life up to 2 years compound filter 1: anti-bacterial filters, silver ion and h13 filters life upto 9000 hrs or 1 year, compound filter 2: cold catalyst filter and activated carbon filters life upto 9000 hrs or 1 year, net weight: 11.3 kg, product measurement : l400xw230xh640mm, components: pre filter and humidifier, compound filter1: anti-bacterial filters, silver ion and h13 filters, compound filter 2: cold catalyst filter and activated carbon filters, fan speed :1-8, alexa-enabled, air quality display: yes, filter rest indicator: yes, 4color air quality indicator : yes, wi-fi & smart app control : yes, filters life : 9000hrs upto 1 years, uv : led, child lock button : yes, sleep mode : with 1-12 hr automatic shut- off time, warranty : 2 years onsite. [ warranty period: 24 months after the date of delivery ] ]
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For corrigendum : supply of t.e.no.gmscl/d-791/rc/2026-27 tablet & capsule,injection,misseleneous items (74 items) - nepafenac eyedrops 0.3percent w/v (bak free), 385000, -, 7913900.00, each ml contains : polymyxin-b 10,000 units, 3446, one patch individually packednb: rate must be quoted for one unit, ketoralac patch 30mg (transdermal), 11000, -, 2509000.00, each 5 ml contain amoxycillin (400mg) plusclavulanic acid (57mg), 3450, 5 ml ffs vial individually packednb: rate must be quoted for one vial, lotepredenol etabonate eyedrops 0.5percent w/v, 102000, ip/usp/bp, 1538200.00, each tube contains : chloramphenicol 1percent w/w, polymixin b sulphate 5000iu, dexamethasone sodium phosphate 0.1percentw/w, 3454, 5 ml ffs vial individually packednb: rate must be quoted for one vial, sodium chromoglycate eyedrops 4percent w/v, 61000, ip/usp/bp, 774900.00, clindamycin phosphate gel, 3467, 100 ml bottle individually packednb: rate must be quoted for one bottle, distilled water for humidifier, 1146000, ip, 656800.00, each 2.5 ml contains levosalbutamol sulphate eq. to levosalbutamol 0.63 mg, 3471, box of 5 x 2.5 mlnb: rate must be quoted for 5 amp., levosalbutamol metered dose inhaler (50 mcg ), 281000, ip, 24398800.00, each capsule contains budesonide 400 mcg, 3475, 30 ml bottle individually packednb: rate must be quoted for one bottle, nepafenac eyedrops 0.3percent w/v (bak free), 385000, -, 7913900.00, each ml contains : polymyxin-b 10,000 units, 3446, one patch individually packednb: rate must be quoted for one unit, ketoralac patch 30mg (transdermal), 11000, -, 2509000.00, each 5 ml contain amoxycillin (400mg) plusclavulanic acid (57mg), 3450, 5 ml ffs vial individually packednb: rate must be quoted for one vial, lotepredenol etabonate eyedrops 0.5percent w/v, 102000, ip/usp/bp, 1538200.00, each tube contains : chloramphenicol 1percent w/w, polymixin b sulphate 5000iu, dexamethasone sodium phosphate 0.1percentw/w, 3454, 5 ml ffs vial individually packednb: rate must be quoted for one vial, sodium chromoglycate eyedrops 4percent w/v, 61000, ip/usp/bp, 774900.00, clindamycin phosphate gel, 3467, 100 ml bottle individually packednb: rate must be quoted for one bottle, distilled water for humidifier, 1146000, ip, 656800.00, each 2.5 ml contains levosalbutamol sulphate eq. to levosalbutamol 0.63 mg, 3471, box of 5 x 2.5 mlnb: rate must be quoted for 5 amp., levosalbutamol metered dose inhaler (50 mcg ), 281000, ip, 24398800.00, each capsule contains budesonide 400 mcg, 3475, 30 ml bottle individually packednb: rate must be quoted for one bottle, nepafenac eyedrops 0.3percent w/v (bak free), 385000, -, 7913900.00, each ml contains : polymyxin-b 10,000 units, 3446, one patch individually packednb: rate must be quoted for one unit, ketoralac patch 30mg (transdermal), 11000, -, 2509000.00, each 5 ml contain amoxycillin (400mg) plusclavulanic acid (57mg), 3450, 5 ml ffs vial individually packednb: rate must be quoted for one vial, lotepredenol etabonate eyedrops 0.5percent w/v, 102000, ip/usp/bp, 1538200.00, each tube contains : chloramphenicol 1percent w/w, polymixin b sulphate 5000iu, dexamethasone sodium phosphate 0.1percentw/w, 3454, 5 ml ffs vial individually packednb: rate must be quoted for one vial, sodium chromoglycate eyedrops 4percent w/v, 61000, ip/usp/bp, 774900.00, clindamycin phosphate gel, 3467, 100 ml bottle individually packednb: rate must be quoted for one bottle, distilled water for humidifier, 1146000, ip, 656800.00, each 2.5 ml contains levosalbutamol sulphate eq. to levosalbutamol 0.63 mg, 3471, box of 5 x 2.5 mlnb: rate must be quoted for 5 amp., levosalbutamol metered dose inhaler (50 mcg ), 281000, ip, 24398800.00, each capsule contains budesonide 400 mcg, 3475, 30 ml bottle individually packednb: rate must be quoted for one bottle
Tender For 2000w resistive heating element for electric stove,circular shape multi ring formed out of tubular single element,with outer supporting ring,moisture proof seals on tube ends,outer dia of coil:200mm+-5mm including outer supporting ring,isi certified brand and suitable for working on 230v ac,50hzsupply. ]
Tender For supply of transparent tape 0.5 inch , transparent tape 1 inch , brown tape 2 inch , paper cutter big size , scale , highlighter light yellow colour , binder clip 32mm 25mm 35mm , pilot pen v5 or uniball green red blue black , stapler no 10 , stapler pin no.10 small , eraser , cello tape coloured 1 inch blue red green , finger grip medium , pencil hb dark , tag good quality small , box file , stapler large kangaro , stapler pin large , ball pen blue black red , u clip round shape best quality , paper pin t shape , binder clip medium , sketch pen black , permanent marker pen for cd , duster cloth white , cd cover , cd , file binder , correction fluid whitener , water jug 2.5 ltr , paper weight , poach with bucket , wiper , transparent reading and writing table top , tea and coffee maker machine , water dispenser good quality , glue stick , dustbin with lid , broom soft , broom coconut , battery for wall clock , glass medium borosil , mosquito refill all out , toilet cleaner , floor cleaner phenol 1 ltr , collin spray , dettol hand wash liquid , room freshener , naphthalene ball 100 gms , stapler pin remover , gum bottle big size , punching machin big size , hit spray for mosquitoes , dak bag for daily dispatch , aroma diffuser humidifier , beverage cup warmer auto shu off coffee warmer pad for office , glass coster set of 06 , coffee mug set of 06 nos , streak tissue box holder with automatic spring , toilet rim hanger , toilet bowl cleaner tablets pkt for 20 nos , plastic spiral ring for spiral binding 15mm , spiral binding cover pkt of 100 sheet , routtering pen , wall clock , paper xerox legal size , envelope 9.9 x 4.5 brown colour heavy quality , paper xerox a4 size , canon cartridge 303 , flag three colour , flag self adhesive big , register 5 qr hard top , register 4 qr hard top , register 3 qr hard top , file cover plain white , automatic shoe polishing machine
Tender For corrigendum : procurement of “building spares and outdoor supply source. - geyser assembly 6-hole, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, geyser coil 2kw, geyser coil, 2 kw, 230 vac, 25 ltrs capacity, thermostat for geyser type-9-inch length, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, electric geyser neon indicator light red, 240v ac red indicator light pilot lamp, neon bulb, electric geyser neon indicator light green, 240v ac green indicator light pilot lamp, neon bulb, gyser model: ap-25v, cap:25ltrs, racold,crompton arno neo 25-l 5 star rated storage water heater (geyser) with advanced 3 level safetybrand cromptoncapacity 25 litres power source corded electricproduct dimensions 337.5w x 54.2h cmspecial feature auto restart, fast heating, geyser safety valve, for, 25 litre capacity geysers, make: crompton., cut out relay for geyser- type 9-inch, supply voltage-250v ac required for, 25 litre capacity geysers, make: crompton, ceiling fan, with copper winding coilnumber of blades-3, power consumption-52w, motor speed-380 rpm, design type-economy, type-ceiling fan, bee star rating-1, body material-aluminium, colour-white, 2 years company warranty, make-havells, crompton, bajaj, usha., portable type extension cable reel, without cable, portable i.e. lift & carryextension cable reel, heavy gaugetubular frame, sheet steel roller and al. discs with 2nos. m/c outletsocket 20a 3pin. reel capable of loading 50mtrs. 3core x 2.5mm.sq.pvc/pvc round sheathed flexible cable. (without cable)., power extension board - rating -15 amp, single phase extension board with 4core 2.5 sq.mm pvc insulated flexible cable (30 meter)component to be included in the board as bellow:1. 25a 2-pole mcb and 25a 2-pole rccb at incoming.3. 01 no s 1 phase 15a industrial socket with plug top and individual switch circuit4. 03 no s 1 phase 15a socket with individual switch circuit, industrial type extension box, fabricated from 16swg crcasheet of size 350mm x 250mm x 250mm. tower type powdercoated in deep orange shade gasketed doors conforming toip 55 and with the following components duly wired: -incomer: mcb and indication lampoutgoing: 4 no s f 10a socket & plug top each individuallycontrolled by a 10a dp rotary switch.