Tender For supply & fitting fixing of (0-4) mtrs range mechanical level indicator at gaighata glr under habra-gaighata surface water based w/s schemeunder emsd-i, phe dte.in 24pgs(n).
Tender For purchase of lab equipments for ice dept - purchase of lab equipments for ice dept, i/p and p/i converter (iemcode:g002) i/p converter:(4 20) ma to (3 15) psi conversion. p/i converter:(3 15) psi to (4 20) ma conversion. air filter regulator (afr):20 psi regulated air supply. built-in current source. 3 digit led display for process indication. power supply: 230 v ac, 50 hz. mounting:bench-top / panel-mounted trainer configuration., level measurement using float and sight glass indicator- itemcode: g005specifications: sight glass level indicator. float type level indicator. power supply:230 v ac, 50 hz. monoblock pump:0.5 hp / 1 hp. sump tank., 8051develop ment board with usb/rs 232 cable to connect with computer (item code: g008)specifications: communication interface:usb / rs-232. on-board facilities:8 output leds,8 input switches,ldr,reed switch,8-bit adc,8-bit dac. display interfaces:seven-segment display,16 2 lcd interface. motor interfacing:stepper motor with driver,dc motor with h-bridge driver, 8 bit adc/dac interface board (item code: g009)specifications: thermistor / lm35 input in one channel. variable input (0 5) v in another channel. 8 leds for digital output indication.. necessary control signals provided for adc0809. 8-bit dac using dac0808. 8-bit digital input from controller. single-channel dac output:(0 10) v. power supply: 12 v or 15 v for analog circuitry, water level measurement trainer kit using capacitive type transducer (item code: g020) tabletop model with transparent acrylic tank of approximately 50 cm height. capacitive type level sensor for continuous level measurement. sensor output: (4 20) ma and/or (0 5) v with built-in signal conditioning. vertical pump for water circulation from sump to tank. flow control valve, overflow, and drainage arrangement. digital display for water level indication in cm. power supply: 230 v ac, 50 hz, single phase. in-built regulated dc power supply for sensor and control circuit. mounted on powder-coated ms frame for laboratory use. suitable for calibration and study of capacitive level measurement., flow measurement using electromagn etic flow meter(item code: g021)specifications: medium: water (salt water / bore well water). electromagnetic flow measurement: instantaneous flow rate and totalized flow indication. electromagnetic flow meter: integral mounted type. power supply: 90 260 v ac, 50 hz. minimum media conductivity: 15 s/cm. flow rate unit: m /hr. operating pressure: up to 10 kg/cm . electrode material: ss-304 / ss-316 / ss 316l. lining material: ptfe / neoprene / hard rubber / pfa. line size: 15 nb 25 nb. flow range: 0.1 10 m /hr. connection type: flanged. display: digital indication for flow rate and totalized flow. water pump: submersible type, 230 v ac, 50 hz. water tank: approximately 20 25 liters capacity. flow control valve provided. drain valve and overflow arrangement provided. mounted on powder-coated ms frame suitable for laboratory use.
Tender For bid to ras bid to ras corrigendum : supply of wx9771615262 drg: 31611770128 rev: 00 condenser air evacuation packa ge (vacuum pump) 30scfm itemid: , w96716155317 drg: - rev: 00 complete vacuum pump (bare shaft vacuum pump) spec: he57016 rev: 04 itemi , w96716155465 heat exchanger for vacuum pump package. spec: he57016 rev: 04 size: - itemid: bh010 , wx9771615270 terminal plate for main motor of vacuum pump size: ----- itemid: bh010 , wx9771615289 heaters for main motor of vacuum pump size: ---- itemid: bh010 , wx9771615297 greasing arrangements for main motor of vacuum pump size: --- itemid: bh010 , w97716155067 bearing for motor of vacuum pump (30 scfm) (1set= 2nos) spec: he57016 rev: 04 size: to s , wx9771615300 terminal plate for rc pump mot or size: ---- itemid: bh010 , wx9771615319 heaters for rc pump motor size: ---- itemid: bh010 , wx9771615327 greasing arrangements for rc p ump motor size: ---- itemid: bh010 , wx9771615335 bearing for for rc pump motor (1set= 2nos) size: ---- itemid: bh010 , w96716155325 main motor for vacuum pump spec: he57016 rev: 04 size: - itemid: bh010 , wx9771615343 motor for recirculation pump for 30 scfm vacuum pump size: --- itemid: bh010 , w97716152033 temperature element for vacuum pump spec: he57016 rev: 04 size: - itemid: bh010 , w97716152041 thermowell for temperature element spec: he57016 rev: 04 size: - itemid: bh010 , w97716155822 pressure transmitter for vacuum pump system: 0-1 bar abs spec: he57016 rev: 04 itemid: b , w96716155244 drg: 31611770051 rev: 00 temperature transmitter for vacuum pump spec: he57016 rev: 04 i , w96716155813 level transmitter for vacuum pump spec: he57016 rev: 04 size: - itemid: bh010 , w96716155210 drg: 31611770047 rev: 00 differential pressure switch for vacuum pump. spec: he57016 rev , w96716155490 flow indicator cum switch for vacuum pump spec: he57016 rev: 04 size: - itemid: bh010 , w97716155733 drg: to suit original supply rev: 00 pressure gauge (0 to -1 bar) itemid: bh010 , w97716155741 drg: to suit original supply rev: 00 pressure gauge (service water) itemid: bh010 , w97716155466 temperature gauge 0-100 deg c, for vacuum pump heat exchanger size: 0 to 100 deg c dim. , w96716155457 differential pressure gauge for vacuum pump package duplex filter spec: he57016 rev: 04 , w97716155849 drg: to suit original supply rev: 00 air flow meter (rotameter) for vacuum pump system s , w97716155547 level gauge for vacuum pump separator tank spec: he57016 rev: 04 size: to suit original , w97716117106 supervision of commissioning lump sum per man day charges at site, including every expe , w97716117114 supervision of commissioning lump sum per visit charges (to & fro) including travelling
Tender For repair, maint and replacement of main pipelines, panels, cables, sluice valve, water level indicator, rewinding of pumpsets etc including allied works at zone b area of bagrakote mil stn under ge sevoke road
Tender For repair, maint and replacement of main pipelines, panels, cables, sluice valve, water level indicator, rewinding of pumpsets etc including allied works at zone a area of bagrakote mil stn under ge sevoke road
Tender For supply of grill sheet lh , grill sheet rh , front cab bush , panel board lh , panel board rh , head light , director indicator light , bolt , nut , fan belt vee ribbed , head fuel filter , catridge fuel filter , level sensor , element lubricant oil filter , radiatort top hose , radiator bottom hose , radiator mounting rubber pad lower , return line hose , service indicator , v clamp , ignation switch , fuel stainer , fuel filter with primer , oil filter , fuel slouite , hyd filter , hyd control volve seal , arm cyl seal kit , control valve hose , fuel pipe line set , water temp guage , tube inner 10 16 point , tubless tyre nozle , fuel tank filter cap , hyd tank filler cap , fuel line main , fuze mix 10 15 20 amp , relay all type , indicator , arm rest set
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign