Get complete information related to latest Hydrant Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hydrant Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hydrant Valve Tenders.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For corrigendum : procurement of “building spares and outdoor supply source. - geyser assembly 6-hole, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, geyser coil 2kw, geyser coil, 2 kw, 230 vac, 25 ltrs capacity, thermostat for geyser type-9-inch length, supply voltage-250v ac required for, 25 litre capacity geysersmake: crompton, electric geyser neon indicator light red, 240v ac red indicator light pilot lamp, neon bulb, electric geyser neon indicator light green, 240v ac green indicator light pilot lamp, neon bulb, gyser model: ap-25v, cap:25ltrs, racold,crompton arno neo 25-l 5 star rated storage water heater (geyser) with advanced 3 level safetybrand cromptoncapacity 25 litres power source corded electricproduct dimensions 337.5w x 54.2h cmspecial feature auto restart, fast heating, geyser safety valve, for, 25 litre capacity geysers, make: crompton., cut out relay for geyser- type 9-inch, supply voltage-250v ac required for, 25 litre capacity geysers, make: crompton, ceiling fan, with copper winding coilnumber of blades-3, power consumption-52w, motor speed-380 rpm, design type-economy, type-ceiling fan, bee star rating-1, body material-aluminium, colour-white, 2 years company warranty, make-havells, crompton, bajaj, usha., portable type extension cable reel, without cable, portable i.e. lift & carryextension cable reel, heavy gaugetubular frame, sheet steel roller and al. discs with 2nos. m/c outletsocket 20a 3pin. reel capable of loading 50mtrs. 3core x 2.5mm.sq.pvc/pvc round sheathed flexible cable. (without cable)., power extension board - rating -15 amp, single phase extension board with 4core 2.5 sq.mm pvc insulated flexible cable (30 meter)component to be included in the board as bellow:1. 25a 2-pole mcb and 25a 2-pole rccb at incoming.3. 01 no s 1 phase 15a industrial socket with plug top and individual switch circuit4. 03 no s 1 phase 15a socket with individual switch circuit, industrial type extension box, fabricated from 16swg crcasheet of size 350mm x 250mm x 250mm. tower type powdercoated in deep orange shade gasketed doors conforming toip 55 and with the following components duly wired: -incomer: mcb and indication lampoutgoing: 4 no s f 10a socket & plug top each individuallycontrolled by a 10a dp rotary switch.
Tender For supply of e.p rubber seats for juice heater exhaoust valve heat resistance 250c, size out dia 550, bore 350mm, thickness 25mm , e.p. rubber seat for juice heater double beat valve size out dia 280mm, bore 30mm, thickness 18mm. , butyl rubber seat for quintipal set main hole as per our hand sketch. , neoprene rubber strip for juice clarifiregarlock closer. , neoprene rubber strip for juice heater size 15mm x 15mm x 20mm , neoprene rubber strip for vapour line juice heater size 18mm x 20mm x 20mm. , neoprene rubber strip for 2nd set vapour line juice heater heating surface 500m2, as per our hand sketch. , e.p. rubber seats for exhaust valve 32 inch angle type for new vapour cell heat resistance 250c size outer dia 850mm, bore 650, thickness 25mm. , e.p. rubber seat for exhoust valve angle type valve 32 inch as per our drawing no. b.h. r.u. 01.2023 24 , e.p. rubber taper plug for 42mm id s.s. tube size for quitipal set.
Tender For maintenance and repair to fire fighting system pipe lines, stand post, hydrantvalves, hose boxes etc. at ins kalinga, drdl, ins karna and nad bheemunipatnam.
Tender For corrigendum : provision of electrical equipment against ber equipment held on charge of ge i cg goa - taking down existing industrial socket, indoor/outdoor unit of split type acs of any capacity and size with voltage stabiliser etc. contractor will carefully remove the aforesaid equipment from site and deposit to mes store under age e/m goa complete all as specified and directed., taking down old aluminium/copper sub main wiring of any type and capacity incl. all accessories and all as directed. note : (i) old dismantled wiring and accessories will be contractors property and credit will be charged against schedule of credit., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 1.5 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make: voltas, lg, bluestar, hitachi., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 2.0 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make : voltas, lg, bluestar, hitachi., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 4 kva. make: v-guard, luminious, microtek., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 5 kva. make: v-guard, luminious, microtek., m & l for sub main wiring with two runs of single core 4 sqmm frls copper conductor pvc insulated unsheathed cable as per is 694-1990 (third revision) drawn through & incl casing and caping of suitable size with all accessories such as tees, elbows,couplings, junction boxes etc, as required fixed on wall along with one run of 4 sqmm single core frls insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. note : (i) two runs of phase & neutral wire, one run of earth continuity conductor cable and one run of casing & capping will be measured as one unit for payment purpose.(ii) the wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads., s & f single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole c series mcb 20 amps complete all as specified., supply and fix refrigerators not less than 310 litres, electric driven (single phase), bee 5 star rate with the following features i.e frost free, double door, auto defrost to stop ice builtup, adjustable temperature controller, double door with separate compartment for freezer inverter type compressor with energy efficiency of 5 star rating, tuffened glass shelf complete with an overall product warranty of one year & 10 year on compressor complete including all as specified and directed. note - old removed item shall be deposited in mes store., supply and fix electric water heater, storage type fibre body with copper heating element upto 2 kw capacity 25 litre, bee 5 star rated complete with all accessories such as safety valve, thermostate, nrv, pvc connection pipe and plug top 15 amps etc. including taking out unserviceable one complete all as specified and directed. note - old removed geyser shall be deposited in mes store. make orient cat