Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For providing of custom bid for services - repair of faulty siemens smart line module type - 6sl31306te236aa3,custom bid for services - repair of faulty siemens double motor module type - 6sl31202te130aa3,custom bid for services - repair of faulty siemens op15 module type: 6fc5203-0af05-0ab0
Tender For supply of repair of ptz camera not powering on , repair of ptz camera lens damage , repair of ptz camera motor faulty , repair of ups 1 kva , repair of 4 tb nvr port faulty , repair of 4 tb nvr not booting , replacement of utp cable , repair of 8 port poe switch , repair of 43 inch led monitor display flickering , repair of 43 inch led monitor backlight faulty , repair and servicing of desktop computer , repair and servicing of nvidia graphics card , repair and servicing of optical in out camera , replacement of ofc 12 core , replacement of power cable
Tender For repair and maintenance of firefighting equipment at cutn 5 hp motor hydrant service work and rope, cupping, soft service, faulty shaft replacement, bearing replacement, pvc motor cooling leaf, 5 hp motor hydrant panel service work ,labour charges and transport charge
Tender For corrigendum : providing of custom bid for services - repair and rectification of faulty siemens single motor module of vertical turret lathe (vtl) machine, asset code: spl00246 installed in 612 shop of 105 hangar of sukhoi engine division
Tender For providing of custom bid for services - repair of faulty siemens spindle motor type - 1ph7 184-2qf030bc0,custom bid for services - repair of faulty siemens active line module type - 1p 6sl3130-7te28-0aa3,custom bid for services - repair of faulty siemens single motor module type - 1p 6sl3120-1te31-3aa3
Tender For providing of custom bid for services - repair and rectification of faulty siemens make manipulator motor of robotic plasma coating equipment asset code sps00056 installed in 631 shop of 105 hangar of sukhoi engine division
Tender For bid to ras corrigendum : supply of split ac at bsnl surendranagar oa : - cm of 1.5tr non inverter split ac units , replacement of blower fan motor in 1.5 or 2 tr ac unit , replacement of blower drum in 1.5 or 2 tr ac unit , replacement of condenser fan motor in 1.5 or 2 tr ac unit , replacement of condenser fan blade in 1.5 or 2 tr ac unit , pcb repair for indoor unit of 1.5 or 2 tr ac unit , pcb repair for outdoor unit of 1.5 or 2 tr ac unit , replacement of 1.5 tr rotary compressor in 1.5 tr ac unit , replacement of 1.5 tr rotary compressor in 2.0 tr ac unit , replacement of 25 or 35 mfdcapacitor in 1.5 or 2 tr ac unit , replacement of 2 pole 25 amp contactor for 1.5 or 2 tr ac unit , replacement of 4 or 6 way terminal box for 1.5 or 2 tr ac unit , water service for 1.5 or 2 tr ac unit , blower service for 1.5 or 2 tr ac unit , charging or topping up r22 or r134 gas in existing 1.5 or 2 tr ac unit , replacement of 50mm thick synthetic air filter for 1.5 or 2 tr ac unit , sitc of auto sequential micro controller for 2 no split or window ac units , replacement of faulty 25 a sp mcb in existing db for 1.5 or 2 tr ac unit , site visit for ac fuult clearing with minor repair
Tender For supply of carry out b check servicing of 320 kva dg set as per specifications , replacement fauly battery and sf of 12v 130 ah battery with 2 year waranty , sf 24v smps battery charger 10 16a , repairing of pumps as required , repair 3 hp borewell pump incl pull out and lowering , attending fault with monor repair and service for 7 or 7.5 tr pakckage ac , repair of split ac incl gas charging except compressor , rewinding of condenser motor for package ac unit 3 phase , supply and charging r22 gas incl notrogen pressure test for package ac units , repalcment of time relay circuit for package ac units , replacement of control card in existing afd system with testing as reqd , replacement of zone card in existing afd system with testing as reqd , replacement of power card in existing afd system with testing as reqd , sf 12v 26ahm battery for existing afd system with testing as required. , laying pvc or xlpe cable in ground upto 35 sq mm as required , laying pvc or xlpe cable on wall or surface upto 35 sq mm as required , supply and making cable end termination for 2 core 6 sq mm al cond cable , testing of existing co2 type fire extinguihsers , refilling of existing co2 type fire extinguihsers , replacment of faulty compressor of extg split ac units with gas charging