Get complete information related to latest Hydraulic Pipe Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hydraulic Pipe Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hydraulic Pipe Tenders.
Tender For supply of hydrolic seal , oil filter , air filter , fuel filter , hydraulicpipe , cabin windshield glass large , cabin windshield glass small , silicon , back light
Tender For mgsy/25-26/gopalganj-1 /01 - high level bridge across river on barai patti to niranjana janewali path me dhawast screw pipe pul ke asthan par new pul nirman in block - gopalganj , rwd division gopalganj-1 , district - gopalganj , bihar, pile load test on single vertical pile in accordance with is:2911(part-iv) including dynamic load test for its integrity , length & capacity a) initial and routine load test, pile load test on single vertical pile in accordance with is:2911(part-iv) including dynamic load test for its integrity , length & capacity a) initial and routine load test, pile load test on single vertical pile in accordance with is:2911(part-iv) including dynamic load test for its integrity , length & capacity b) lateral load test, earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. upto 3.000 m depth, providing and constructing temporary island 16 m diameter. all complete job as per specifications and direction of e/i., providing service road etc. all complete job as per specifications and direction of e/i., providing steel liner 6 mm thick for piles including fabricating and setting out as per detailed drawing., bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres(extra pile length). stripping off rcc m35 in the pile up to cut off level and disposal of debris with all leads and lifts., sand filling in foundation trenches as per drawing & technical specification, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., cement concrete for reinforced concrete m - 35 in pile cap complete as per drawing and technical specification, supplying, fitting and placing un-coated hysd bar reinforcement in foundation complete as per drawing and technical specifications., providing rcc m-30 mechanically mixed concrete in abutment shaft & pier shaft with stone aggregate 20 mm nominal size and clean coarse sand of fm-2 all complete job as per design upto 5 m hieght, providing rcc m-30 mechanically mixed concrete in abutment shaft & pier shaft with stone aggregate 20 mm nominal size and clean coarse sand of fm-2 all complete job as per design beyond 5 m and upto 10m hieght, supply fitting & fixing elasto-meric bearing & seismic pad :-- supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weep holes in abutment cap with 100mm dia ac pipe:-- providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications., supplying, fitting and placing hysd bar reinforcement in substructure complete as per drawing and technical specification., back filling behind abutment, wing wall and return wall, complete as per drawing and \technical specification.(sandy material ), providing and laying of filter media with granular materials/stone crushed aggregate satisfying the requirement laid down in ci. 2504.22 of morth specification of not less than 600mm behind abutment, wing and return wall to th
Tender For mgsy/25-26/teghra/01 - construction of h.l rcc bridge ( 6 x 21.750 m) in alapur to pasopur & l021 to pakthaul , ( khijir chak abm kirtoul ke bich balan nadi par pul ) under teghra block in the district of begusarai, excavation for structures , earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. up to 3.00 m depth ., levelling course for pile cap , providing and laying of pcc m15 levelling course 100mm thick below the pile cap., providing and laying reinforced cement concrete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5 , rcc grade m -35 in pile cap, bored cast in situ piles r.c.c m-35 , pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth with all lift and lead up to 1200 m, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawing and technical specifications , tmt in foundation , refer bbs ,qty = 54.273+16.411+74.929+ 29.651= 175.264, 6mm thick. steel liner as per drawing and technical specification ., providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. well. assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth @ rs. 3768.00 for each island., pile load test on single vertical pile in accordance with is:2911(part-iv) 1985, a) initial load test @ 2.5 times load on 1 pile, b) routine load test @ 1.5 times load on 2% pile, c) lateral load test, confirmatory boring at abutment and pier location, back filling behind abutment, wing wall and return wall complete as per drawing and technical specification, providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of morth specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification., plain/reinforced cement concrete in sub-structure complete as per drawing and technical specificationsheight upto 5m , rcc grade m30, plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications ,rcc grade m30 , height 5m to 10m, supplying, fitting and placing hysd bar reinforcement in sub-structure complete as per drawing and technical , reinf qty = 20.810+28.454+1.762+0.313+1.289+1.139 =53.77, providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., furnishing and placing reinforced/prestressed cement concrete in super-structure as per drawing and technical specificatio,rcc grade m 30, height 5m to 10m, reinforeced cement concrete m30 grade approach slab including reinforcement and formwork complete as per drawing and technical specification, pcc m15 grade leveling course below approach slab complete as per drawing and technical specification, construction of rcc railing of m30 grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical rcc post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space b
Tender For estimate for the work of removal of silt and jungle of clearance bd-1 of distry-1 from ch. 0.00 to 3.00 km of sli and lateral- 2 of bd-1 of distry-1 of sli from ch. km 0.00 to 4.00 (excluding pipe aquaduct)