Get complete information related to latest Hydro Plant Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hydro Plant Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hydro Plant Repair Tenders.
Tender For corrigendum : annual maintenance work of 33 kv and 11 kv vcb installed at various s/s fed from 132 kv power transmission centre majhola in the jurisdiction of eudd-(technical), 33 kv- moradabad
Tender For corrigendum : annual maintenance work of 33 kv and 11 kv vcb installed at various s/s fed from 220 kv power transmission centre majhola, 132 kv aashiyana and awas vikas in the jurisdiction of eudd-(technical), 33 kv- moradabad
Tender For bid to ras tender for supply of fixing self regulating heat tape cable insulation and accessories in ppr pipe - providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems , providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress , providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions , providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area , providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life
Tender For corrigendum : route survey for construction of 220kv transmission line for power import to oil, madhuban from 220kv namrup gss and preparation of master plan for construction of 1(one) no. of 220/132/33kv grid substation (ais and gis) at oil, madhuban
Tender For tender for supply of mmv trade equipments -auto electrical test bench , car jet washer with standard accessories , starter motor axial type , working model of air brake assembly , cut section working model of automatic transmission gear box , steering assembly power streeng elctric assisted , multi scan tool to scan engine , spring tension tester , air bag simulator with accessories , tube tyre vulcanizing machine 220 v , ultrasonic injection cleaning equipment flow analysis and spray pattern test , working model of torque converter model of lmv
Tender For supply, delivery and installation of advanced testing mechanism, lab equipment for conducting daily quality of drinking water in tanuku municipality supply, delivery & installation of compact photometer pf-12plus make: mn, germany (or) any equivalent isi make model no: 919250 technical specifications: type: filter photometer with microprocessor control, self-test and auto-calibration light source: xenon lamp optical system: automatic filter wheel with 7 interference filters wave length: 345 nm / 436 nm / 470 nm / 540 nm / 585 nm / 620 nm / 690 nm plus 1 compartment for an additional filter, 860 nm led for ntu measurement wave length accuracy: ± 2 nm, bandwidth at half transmission: 10 nm?12 nm photometric range: ± 3 e photometric accuracy: ± 1 % long term stability: < 0.002 a/h measuring modes: more than 100 preprogrammed tests and special methods, absorbance, transmission, factor, standard, nephelometric turbidity measurement; 50 freely programmable methods pre programmed tests: nanocolor tube tests, visocolor eco tests and powder pillows turbidity measurement: nephelometric turbidity measurement at 860 nm (based on iso 7027), 1?1000 ntu cuvette slot: round tubes 16 mm od data memory: 1000 results, glp conform display : backlit graphic display, 128 x 64 pixel auto off: inactive or automatic shutdown after 5 min, 10 min, 15 min, 20 min, 60 min internal quality control: with nanocontrol nanocheck 2.0 operation: self-explanatory menu guidance, plastic foil keypad, test selection via parameter lists language: de / en / fr / es / it / nl / hu / pl / pt / cz / id / sl / tr / my operating range: 10?40 °c (50?104 °f), max. 80 % relative humidity (non-condensing) power supply: via usb power supply, standard or rechargeable batteries or accu-pack weight: 0.7 kg dimensions (l x w x h): 215 x 100 x 65 mm scope of delivery photometer, software dvd, manual, visocolor eco test instructions, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, usb cable, calibration cuvette, cleaning cloth and certificate in rugged case hazardous material: no , supply, delivery & installation of mm42dp-ph,ec,tds portable multi-parameter water quality meter with ph, conductivity electrodes. includes: mm-42dp(main unit)+mm4-ph(1m) ph electrode+mm4-ec(1m) ec electrode make: dkk-toa corporation, japan. technical specifications : measuring method : ph : glass electrode method orp : platinum electrode method conductivity : ac bipolar method dissolved oxygen : optical type temperature : thermistor resistor display unit :custom lcd(with backlight) measurement items/ranges : ph : ph0.000 to ph14.000 mv (orp) : -2000 to 2000mv conductivity:0.1ms/m to 10s/m d0: 0.00-20.00mg/l or 0.0 to 200.0% electrical resistivity:0.1o.m to 10ko.m (converted from electric conductivity) salinity (nacl):conversion from electrical conductivity salinity (pss: practical salt):conversion from electrical conductivity total dissolved solids (tds):conversion from electrical conductivity temperature:0.0to100.0°c display range : ph : ph-2.000to ph16.000 mv (orp) : 0to99.99mg/l 0to999.9mg/l 0to9.999g/l 0to99.99g/l 0to999.9g/l (automatic/manual range switching) temperature :-5.0to110.0°c do:0.00-22.00mg/l or 0.0 to 220.0% display resolution : ph :0.01ph/0.001ph mv (orp) :1mv conductivity :0.05%fs electrical resistivity :0.05%fs, salt :0.01%(nacl)0.01psu(pss) total dissolved solids (tds) :0.01%fs temperature :0.1°c, repeatability (instrument body): ph :within ±0.006ph mv (orp) :±2mv, conductivity :±0.5%fs, do:when combined with 8mg/l ±0.1mg/l or 100%±1% electrical resistivity :±0.5%fs salt :±0.5%fs, total dissolved solids (tds) :±0.5%fs temperature :within ±0.2°c ph temperature compensation range: atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0? electrical conductivity temperature compensation range : atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0°c atc off (no temperature c
Tender For re-conductoring package oh01 associated with transmission scheme for evacuation of power from ratle hep (850 mw) and kiru hep (624 mw): part-b
Tender For request for proposal document for selection of bidder as transmission service provider through tariff based competitive bidding process to develop intra-state transmission project i.e. establishment of 765/400/220 kv ais apta ( dist raigad) is issued by rec power development and consultancy limited
Tender For corrigendum : provn of 200 kva transformer with transmission line for the enhanced power requirement of rnldc at comn complex, hq central comd under ge (e/m) lucknow