Get complete information related to latest Hydro Plant Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hydro Plant Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hydro Plant Repair Tenders.
Tender For tower dismantling and de-stringing of 56 nos. of 132 kv transmission tower from lilo point at 132 kv dumka-lalmatia circuit-ii to adani power ltd.
Tender For request for proposal document for selection of bidder as transmission service provider through tariff based competitive bidding process to establish inter-state transmission system for wr-er inter-regional network expansion scheme-part c is issued by rec power development and consultancy limited.
Tender For request for proposal document for selection of bidder as transmission service provider through tariff based competitive bidding process to establish inter-state transmission system for wr-er inter-regional network expansion scheme part a is issued by rec power development and consultancy limited.
Tender For corrigendum : expression of interest (eoi) from indian companies having experience in metros%2c railways%2c highways%2c marine and port works%2c major bridges%2c tunnels%2c institutional buildings%2c workshops%2fdepots%2c traction and power supply (mrts%2fmetro)%2c railway electrification%2c power transmission and distribution%2c solar power systems%2c railway sandt works%2c telecommunication works%2c and various mechanical works and willing to associate with rvnl for upcoming projects in india and abroad%2e
Tender For work for strengthening of existing earthing system of both 50mva trf1 & trf2 power transformer by special deep boring earthing at 132/33kv gss sariya under the jurisdiction of transmission division, hazaribag
Tender For corrigendum : engineering items ( non authorized dealer)-- , aira valve auto mation ce 1128 valve automation f/b- r/b full bore end type- s/e, size dn 25mm bore seat/stem htfe 98316 bore- 25mm flanged end both side., high flow pump size- 5 inch head- 40 mtr. with motor pump or base freme, s.s. ball valve flange type size- 25mm make- aira, rubber stator for high flow pump size- 4” x 4” model no. rbh4152aabn make- risanshi, rotary screen taflon roller assembly front assembly make- uttam, juice rotary screen, rotary screen taflon roller assembly rear assembly make- uttam, juice rotary screen, rotary screen taflon roller assembly front surface assembly make- uttam, juice rotary screen, ‘b’ mescuite pump spare roter with shaft and gen metel strips pump size- 8 x 8 inch make gita pump, valency welding rod bronzocar- 32 ac/dc size- 3.15mm, valency welding rod bronzocar- 32 ac/dc size- 4.00mm, sapre tyre for following size- f- 60, sapre tyre for following size- f- 70, sapre tyre for following size- f- 80, c.i. pin bush coupling complete assembly with pin bolt with rubber bush size- 10”, c.i. pin bush coupling complete assembly with pin bolt with rubber bush size- 12”, rubber bush for pin bush coupling rubber bush size- id 19 x od 38mm x length- 40mm, en- 8 round bar size- 25mm x 4 mtr., en- 8 round bar size- 30mm x 4 mtr., en- 8 round bar size- 36mm x 4 mtr., en- 8 round bar size- 40mm x 4 mtr., coupling bolt med. en- 8 size bush bolt dia- 19mm bush length bolt- 45mm bolt caller 5mm thick- 2500, thread length- 21mm, 5/8” bsw thread with out thread- 20mm length dia- 5/8 inch, "uc-1500 type uttam make machine continuous machine spare pully housing complete assembly", "uc-1500 type uttam make machine continuous machine spare main housing assembly complete set", "uc-1500 type uttam make machine continuous machine sparebuffer chamber assembly", top scraper for mill no. 3, 4 pitch 35mm material- c.i. 1030 gr. (as per drawing) , "discharge scraper for mill no. 3, 4 pitch 35mm material- c.i. 1030 gr. (as per drawing)", b messacute pump complete 6" x 6" for b messacute without motor make risanshi, top gear transmission make model no. 2340 hbx ratio- 36, s.no. 18026797, top gear transmission make model no. 22300 hbx ratio- 37.85, s.no. 16123824, level tranmitter range - (-2150 to 0 mmh2o) supply - 10.5 to 45vdc, output - 4 to 20ma with installation & trail support warranty - 2 year make - abb/siemens/yokogawa, controller for spray enggineering panel make - winpac model no - wp - 8147 pwr - (10 to 30 vdc) with installation & trail warranty - 02 year, solenoid valve coil with hand regulator make - rotex model - mf42 - 3012x3 - 62g (3/2 way) supply - 230vac, esp level switch probe with controller and cables material - stainless steel no of parts - 4 ports, meadia type - dry material working pressure - 150°c make - eip enviro level control pvt. limited with installation & trail warranty 02 year, mix bad (mb) conductivity sensor cable with its controller work on low cell constant make- ion exchange model - indian con 5000w with installation support warranty 02 year, ph sensor cable with controller make - ion exchange model no - indion 4000 phw with installation & trail supports warranty - 02 year, touch hmi programmed display make - formaplastic model - weintexmt 5017 input power supply 24 vdc warranty - 02 year, power supply transformer make - kasunga model - dvsc 200 aem4it ( ac415/110 . 100v 200va), load cell make - minibea model - cbe1 - 50k warranty 02 year, programmed plc for batch type machine make - mitsubishi electric r5485 & lan card suported model no - fx5u-64m, programmed by formaplastic warranty - 02 year installation service support & trail work, 24 volt dc coil for solenoid valve ip - 65 make - techno as per sample provided, coil for solenoid valve supply - i-230vacol make - rotex as per sample, temprerature controller make - electronic system & devices model - esd9223 warranty - 02 year, plastic chair - ni
Tender For corrigendum : providing of hiring of consultants - milestone/deliverable based - appointment of independent engineer for transmission scheme for evacuation of power from ratle hep (850 mw) & kiru hep (624 mw): part-a; energy (oil, gas, power, renewables); no; hybrid(as specifi..
Tender For corrigendum : providing of hiring of consultants - milestone/deliverable based - transmission system for evacuation of power from mahan energen limited generating station in madhya pradesh; energy (oil, gas, power, renewables); no; hybrid(as specified in scope of work)