Get complete information related to latest Hydrogen Plant Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hydrogen Plant Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hydrogen Plant Tenders.
Tender For auction sale of depot ferrous scrap - scrap ms s&t released items of sort and sizes including, signal base,signal post,root drum,stracher bar,emptyvrla battery box,junction box, stop signal, shunt signal with offset, point machine body , signal pole, signal ladder, unit to aspect, route drum, rodding set, location box, gate boom, signal base, shunt signal, point d bracket, route drum, impedance bond cover, protection cover, half location frame, signal post, plunger, ladder assay, offset bracket, point machine without motor, ground connection/point rodding, ms battery box, gate meeting post, gate pedestal, gate gear box, empty cabinet, strips, plates, rods, transmission assemble, levers, pipes, ladder, fabrication angle channels, signalling electrical substation machinery parts fittings, nut bolts, signalling poles, point motor,cycle machine point plunger, route drum, p bracket, point auxiliary, clamp assly, supporting patti, fuse alarm box, power supply box, rail deflector, point jb, aftc tu jb, relay and all kind of signalling items and other miscellaneous ms gi and ci fittings with or without n/f and other attachments. nf without attachment will not be delivered. note- cutting allowed only for location boxes for easy loading at the time of delivery. location - b by 1.
Tender For replacement of worn out ht and lt power transmission lines, rcc poles, pin & disc insulators at jnanabharathi campus, bangalore university, bangalore.
Tender For providing and fixing guarding (cradle guard) under high power transmission line (11kv) and low power transmission line (1.1kv) spacers to the sagged lt line at jbc,bub
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - transmission substation; substation, switchyard, power house equipment, electrical system or installation; service provider
Tender For corrigendum : annual maintenance work of 33 kv and 11 kv vcb installed at various s/s fed from 132 kv power transmission centre majhola in the jurisdiction of eudd-(technical), 33 kv- moradabad
Tender For corrigendum : annual maintenance work of 33 kv and 11 kv vcb installed at various s/s fed from 220 kv power transmission centre majhola, 132 kv aashiyana and awas vikas in the jurisdiction of eudd-(technical), 33 kv- moradabad
Tender For bid to ras tender for supply of fixing self regulating heat tape cable insulation and accessories in ppr pipe - providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems , providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress , providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions , providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area , providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life
Tender For corrigendum : route survey for construction of 220kv transmission line for power import to oil, madhuban from 220kv namrup gss and preparation of master plan for construction of 1(one) no. of 220/132/33kv grid substation (ais and gis) at oil, madhuban