Get complete information related to latest Idf Meter Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Idf Meter Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Idf Meter Repair Tenders.
Tender For supply of floor mounted indoor type lt distribution set panel with tpn cu bus bar and the following items: incoming: 2 nos. 400a 36ka 4 pole mccb, outgoing: 2 nos. 250a 36ka 4pole mccb, 2 nos. 100a 36ka 4pole panel mccb, 1 no. 63a 25ka 4pole mccb & 1 no. 63a 4 pole rccb. the lt panel should be complete with internal wiring, metering arrangement and all accessories. the panel shall conform to description no. ser/elec/gs/description/lt panel/1/rev-2/june 2025 (size wxhxd - 1600 mm x 1800 mm x 600 mm) the minimum clearance to be maintained for enclosed |indoor air insulated bus bars shall be as follows: phase to earth 26 mm minimum & phase to phase 32 mm minimum. the complete panel should be oem factory made as per latest is specification. all major components should be of same manufacturer as that of panel. make- l&t, bch, havells or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of carriage of pcc and stp poles 8.5, 11 and 13 mtr , carriage of line material , erection of pcc and stp poles 8.5, 11 and 13 mtr , erection of double poles 8.5, 11 and 13 mtr , installation and fixing of 11 kv tpmo. , erection and grouting of stay set , providing and fixing of insulator , laying of acsr weasal, rabbit and dog conductor. , erection of abc conductor , grouting of pcc and stp poles , making of plinth , fixing of earthing rod , chopping of tree branches , providing and fixing of clamps of lt , providing and fixing , carriage and installation of 25 kva transformer , carriage and installation of 63 kva transformer , carriage and installation of 100 kva transformer , carriage and installation of 400 kva transformer , dismantling of old pcc and stp poles , dismantling and removal of conductor , erection of section tee pole , carriage and installation of lt dist box , provding and fixing, filling cable joints , safe carriage of cables , laying of under ground cable , laying of overhead cable , guarding of 11 kv line by gi wire , safe carriage and installation of metering unit , safe carriage and installation of metering cubicle , provding and fixing wearing gi pipe
Tender For supply of supply of earthing rod complete , supply of top channel , supply of droper channel , supply of number plate , supply of danger board , supply of barbed wire , supply of stone pad , supply of clamp , supply of red oxide paint , supply of aluminium paint , supply of t-channel , supply of f- bracket , supply of guarding angle , supply of guarding angle clamp , supply of i-irag bolt , supply of lt fuse set protection unit , safe carriage of new 100 kva t f , safe carriage of 11 kv vcb , safe carriage of fuse set , safe carriage of tpmo , safe carriage of xlpe cable , safe carriage of i d cable jointing kit , safe carriage of o d cable jointing kit , safe carriage of gi pipe , safe carriage of stay set complete , safe carriage of extra stay at angle , safe carriage of acsr dog conductor , safe carriage of acsr weasel conductor , safe carriage of polymeric pin insulator , safe carriage of pin with nut , safe carriage of polymeric disc insulator , safe carriage of disc fitting , safe carriage of st pole , safe carriage of g.i. wire 8 swg , safe carriage of g.i. wire 6 swg , safe carriage of 3 ph-4 w static smart meter , safe carriage of pilfer proof metering cubicle , erection of 100 kva tf , erection of pipe earthing , erection of plinth , erection of fencing , erection of stp pole , erection of paint of pole , erection of danger board , erection of m.s. angle iron , erection of acsr weasel conductor , erection of acsr dog conductor , erection of barbed wire , erection of lt fuse set protection unit , erection of top channel , erection of dropper channel , erection of number plate , erection of stay set complete , erection of extra stay set complete , erection of g.i. wire 8 swg , erection of g.i. wire 6 swg , erection of fuse set , erection of tpmo , erection of xlpe cable , erection of i d cable jointing kit , erection of o d cable jointing kit , erection of 3 ph 4 w static smart meter , erection of pilfer proof metering cubicle , erection of 11 kv vcb , recieved back charges for carraige of dismantling material from site to store.
Tender For tender for supply of periodical maintenance and operation of electrical and mechanical installations involving operation , repairs and maintenance , attending to complaints/faults/ breakdowns and taking rectification action , ensuring serviceability/satisfactory working condition of the systems , carrying-out preventive maintenance , maintenance of records/ documents etc. under this contract on all working days including saturdays , sundays and holidays as per tender specifications , terms & conditions by providing/engaging following minimum number of man power i/c reliever. (a) highly skilled (sr. supervisor) - 1 nos. (b) highly skilled (supervisor) - 1 nos. (b) skilled data entry operator - 1 nos. (c) skilled technician - 14 nos. i/c relievers (d) unskilled helper - 14 nos. i/c relievers total minimum manpower i/c reliever- 31 nos. note- relievers shall do duty of electrician//helper as per site requirement. , carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site. note - empty drum will be provided by aai. , servicing of l&t make , model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel , cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts , releases etc , checking the hardware for wear & tear , checking of termination & tightness , checking for all hardwares for its presence , replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope) , regreasing of the acb parts as recommended by oem , refixing the acb , testing and observance for normal operation of acb complete as required. note - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head. , one time servicing , maintenance , testing , overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv , 630 a , 21ka/3sec , 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual load breaker switch and 01 no. 630a manual vaccum circuit breaker. transformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos. lv componenet - 4 p , 630a , drawout acb - 01 no. 3p 400a mccb for capacitor panel capacitor panel - apfc 200kvar capacitor panel- 01 nos. pss is comprising all above i/c metering , relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer , rmu , ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete. , carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine , di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement. note - the transformer having capacity of 330 ltrs of tranformer oil. , supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement. , one time servicing , maintenance , testing , overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of