Get complete information related to latest Idmt Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Idmt Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Idmt Relay Tenders.
Tender For supply of various type electrical accessories for electrical maintenance work at various municipal properties of part -1 area (mota varachha, utran, bharathana, umra, gothan, abrama, kathor, velanja) falling in the new east (sarthana) zone-tube light and lamp , light & accessories , , 2.0 x 2.0 feet square 36/40 (watt) led fixture for indoor lighting or its equivalent , , philips driver for 2.0 x 2.0 feet square 36/40 (watt) led fixture for indoor lighting or its equivalent, pin: 50w mac, u in: 240 vac, i in 0.22 a max, p.f. ≥0.95, i out: 280ma, v : u out -190 v dc max, self deciaration conforming to is 15885(part 2/sec:13) , , driver for 2.0 x 2.0 feet square 36/40 (watt) led fixture for indoor lighting or its equivalent, sidl-36-600, pin: 36w mac, v in: 230 vac 50hz, i in 160ma, p.f. > 0.9, athd: <10%, i out: 600ma, v : u out-54 v max, is 15885 (part 2/sec:13) , , 18/20 watt, led panel light (square/round), 1700 lumens , , 20/24 led panel light size 12 x 12 inch , , 12/15w led panel light (square/ round), 1020 lumens , , 50-55 watt led flood light fitting having efficacy 100lm/watt, cct 5000 k to 5700k , , 30-35 watt led flood light fitting having efficacy 100lm/watt, cct 5000 k to 5700k , , celling fan & accessories , , supply of 1200 mm sweep (48"), bee 5 star rated, ceiling fan with brush less direct current (bldc) permanent territe magnet motor. , , capacitor 440 v ac,36 uf , , capacitor 440 v ac,50 uf , , capacitor 440 v ac, 100/120 uf , , 1.5 ft celling fan ms pipe , , 2 ft celling fan ms pipe , , 2.5 ft celling fan ms pipe , , 3 ft celling fan ms pipe , , 4 ft celling fan ms pipe , , ding dong bell , , bell/buzzer/hooter , , remote operated ding dong bell , , buzzer , , industrial gong bell 9inch , , standard industrial bell (school bell) 240 v ac 225mm , , standard industrial bell (school bell) 240 v ac 150 mm , , musical bell , , parrot bell , , modular accessories , , modular board , , 2-up pvc modular board surface , , 3-up pvc modular board surface , , 4-up pvc modular board surface , , 6-up pvc modular board surface , tissino type switch, fan regulator & accessories , , tissino type switch 6 amp (simple) , , tissino type switch 16 amp (simple) , , tissino type 2-way switch 6 amp , , tissino type bell push , , tissino type plug 6 amp (simple) 2 in 1 socket , , tissino type plug 16 amp (simple) , , holder adapter , , electronic hum free eme socket type step fan regulator (plug type) , , electronic hum free eme switch type step fan regulator , , one no single pole 16a switch & one no 6/16a universal socket combined (ss combine with box) , , angle holder , , batten holder , , pendent holder , , bakelite celling rose , 10 amp connector strip , , male female 2 pin connector , , other accessories , , electrical insulation tape roll different colour box (r-y-b-n) , , water proof rubber tape , , wooden grip packet , , pvc grip packet , , aluminum strip (10 ft.long) , , rubber clamp (fan) , , pencil cell aaa size 1.5 v , , pencil cell aa size 1.5 v , , 9v battery cell , , 12 v 23 a alkaline battery cell , , aluminum lug pin type for 2.5/4 sq. mm cable/wire , , aluminums lug pin type size 6/10 sq. mm cable/wire , , aluminum lug pin type size 16 sq. mm cable/wire , , copper lug pin type for 2.5/4 sq. mm cable/wire , , copper lug pin type for 6/10 sq. mm cable/wire , , copper lug pin type for 16 sq. mm cable/wire , , aluminum lug ring type size 2.5/4 sq. mm cable , , aluminums lug ring type size 6/10 sq. mm cable , sheet steel powder coated mcb db board-flush/surface mounted 3 phase 8 way ss double door ppi type for 1 phase outgoing horizontal box , , odher equipments and accessories , , l&t mnx 22 power contactors , , relay for up to 3 hp submershible moter starter , , relay for 3 hp to 5 hp submershible moter starter , , relay for 5 hp to 12.5 hp submershible moter starter , , single phase submersible starter with digital ampere and volt meter , , with power contactor, start + run capacitor & start
Tender For supply of earth leakage device/relay (elr), suitable for feeder of lhb power cars control panel, as per model rd3 48 (12-48 v ac/dc) of m/s abb make, or model no. elr-3c (24-48 v ac/dc) of m/s fanox make, or model no. rcm 470ly-21 of m/s bender make, confirming to rcf specification no. edts-103, rev-d, am no. 4.accepted make & model no: as per sr. no. 2 of bom of rcf specification no. edts-103, rev-d, am no. 4 or any other rcf/rdso approved make. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]
Tender For supply of 2.2 kw ac crane drive , 5.5 kw ac crane drive , 11.0 kw ac crane drive , 22.0 kw ac crane drive , 37.0 kw ac crane drive , 55.0 kw ac crane drive , 75.0 kw ac crane drive 3 phase, digital ac crane drive 2.2 kw, ac drive should be suitable for heavy duty operation of 2.2 kw. offered ac drive should be suitable for crane-hoist operation. if, separate software required for crane application, it must be clubbed with supply of material. ac input voltage: 380 to 480v ac 10%, 3 phase, 3 wire, 50 hz; mode of control: bi-directional fully controlled 3-phase ac; speed regulation: 1% of base speed; braking: suitable dynamic braking resistance and chopper unit (external or in-built); acceleration time: 0.1 to 1000s or better; deacceleration time: 0.1 to 1000s or better; overload: 150%-1min, 200%-3.0s; ambient temperature: 0 to 50 c (derating shall not occur below 50 c. in the event that derating occurs below 50 c, the supplier shall provide a higher-rated drive to match the requirement); rated current at 50 c: min. current should be 5.5 amps at 50 c; high starting torque at low speed: 200% starting torque at 0.3 hz; two analog inputs: two nos. analog inputs having signal voltages of 0 to 10 vdc or 4 to 20 ma (configurable); two analog outputs: two nos. analog outputs having signal voltages of 0 to +/-10 vdc or 4 to 20 ma (configurable); six digital inputs: pnp/npn; one relay output: with short-circuit and overload protection; two digital outputs: with short- circuit and overload protection; brake release signals: outputs braking signals based on inverter operating conditions to prevent cargo bed rollback and overrunning; load adaptive control: when the actual load level is lower than the configured load level, the system can be operated at a ratio-multiplied speed (in terms of the configured frequency), resulting in significantly better efficiency; load ) /bid number : gem/2026/b/7563714 * /dated: 20-05-2026 & & / bid document 1 / 29 frequency), resulting in significantly better efficiency; load limiter: maintains the safety and rescuability of suspended loads by stopping when excessive torque is detected and by allowing operation only in the direction opposite to that in which the excessive load was detected; cooling capacity degradation alarm: detects and displays cooling capacity drop due to cooling fin clogging caused by dust and cooling fan airflow reduction; igbt life expectancy forecasting: estimates the power cycle life expectancy of the main circuit s igbt semiconductor device temperature due to frequent acceleration and deceleration stoppages, and displays the estimate before the design life is reached; protection: it must have all standard protections like stall protection, instantaneous power failure, single phasing, over voltage, under voltage, over current, inverter overload, thermal overload etc; display console: it must have alpha numeric display console for programming of drive, fault display and operating condition; dynamic qr code: it must have dynamic qr code for trouble shooting; tuning facility: it must have auto tuning facility. this must enable perfect matching of motor coupled to load with regards to optimum acceleration time, deceleration time, speed regulation etc; drive programming software: suitable drive programming software along with necessary connecting cable and adapter for connection with laptop and drive should be provided to get online with the offered drive (laptop not in scope); automatic voltage regulation: it must have automatic voltage regulation function to maintain high starting torque even at reduced voltage; regenerative option: it must be capable of regenerative operation; communication protocol: modbus (rtu/serial) or ethernet (tcp/ip); make of drives: fuji- electric/yasakawa/schneider/abb only; suitable dynamic breaking resistance unit of 60% wattage rating of drive, however the value of resistance is to be decided by manufacturer as per their technical manual for crane-ho
Tender For tender for supply of ac under voltage_over voltage circuit of solid state sensing type alv-d2 for ov , input surge protection network (mov based) in-20ka , imax-40ka up-2.2kv , current transformer 80 a / 5 a , cl 1.0 , 5 va , current transformer for ac ammeter am1 , 75a/5a , cl1.0 , 5va , emc filter (ac side) (mf-423-3-3d-80a-440vac , case r4) 440 v , 80 a ac , emc filter (ac side) (mf-423-3-3d-60a-440vac , case r7) 440v/60a ac , surge suppressor mov for ac input 275 v/20d (mov1-3) , surge suppressor mov for ac input 510v ac (k510) (mov 4-6) , control transformer for ac auxiliary supply 456 / 240vac , 500va , cooling fan with fan failure alarm contact 230v ac , 6 inch , 50w , 3ph , ac power capacitor 7.5kvar , 480v , 3ph , ac power capacitor 10kvar , 480v , ac reactor for pfc1 25a , 1550 micro henry , three phase , double wound , impregnated naturally air cooled mains transformer 50.03 kva (456/300v) , three phase , double wound , impregnated naturally air cooled mains transformer 38.21kva (456/40v) , semi-conductor hrc fuses for the rectifier bridge 80et , 690v , semi-conductor hrc fuses for the rectifier bridge 690v/500a (500mmt) , rectifier fuse fail detector circuit for rectifier fuse 220v dc , rectifier fuse fail detector circuit for above fuse 24v dc , diode skkd101/16 , scr1 12 425 a 12nos (425a/1000piv) , d1 300a 300a/600piv , interphase transformer 1.238kva , interphase transformer 1.13kva , shunt for cpc1 , cpc2 sh 100a/75mv , shunt for cpc1 , cpc2 sh 600a/75mv , bleeder resistance 350 ohm 750w 2 in parallel , bleeder resistance 50 ohm 100w 4 in parallel , bleeder resistance 2k 50w 2 in series , bleeder resistance 50 ohm 50w , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function 230v ac 744 a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 177a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 1014 a , filter choke 118 a 650 micro h , filter choke 676 a 16.5 micro h , filter condenser fuse fail detector circuit 220v dc , filter condenser fuse fail detector circuit 24v dc , 3 phase scr full controller card for scr firing 220v dc , 3 phase scr full controller card for scr firing 24v dc , 2 c_o plug in type auxiliary relay with base for ineterlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.4v function and interlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.75v function and interlock 240v ac 2c_o , double disk type wire wound potentiometer to adjust output voltage in float mode 10k _3w , potentiometer pcb for voltage control circuit for cpc1 and cpc2 mt 120a , potentiometer pcb for current control circuit for cpc1 and cpc2 mt 121a , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , 2 c_o plug in type auxiliary relay with base for trip latch function 240v ac 2c_o mpc , charger silicon blocker diode diode skr300_12 , 300a_1200 piv , 2 c_o plug in type auxiliary relay with base as contact multiplier for mccb4 220v dc 2c_o , load under voltage circuit of solid state sensing type for alarm indication and pfc , load under voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for pfc and trip function , d
Tender For supply of electrical items for air compressors and eot crane installed at ash handling system of unit 1 and 2 (2x600 mw), katpp, rvun, jhalawar - single phase preventer- wtr d1, aux. supply 240 vac , contactor- activa- av1-150 75 kw, 415 volt ac, 50 hz ith= 200 a, u = 1000 v aux. contact ac 15 4a, 415 v, coil voltage -220 vac , over load relay- activa avr3-83, 124-198 amp, class-20 , power contactor, 3 phase 415v ac 4 kw/9a 3 pole 3rt1023-1a, model no.:-3zx1012-0rt02-1aa1, coil voltage rating- 110 v acm , thermal overload relay 3ru1926-3aa01 with 1 no & 1nc 0.5 to 2a model no:-3zx1012-0ru11-1aa1 , thermal overload relay- 3ru1926-3aa01 with 1no&1nc 4.5 to 6.3a model no:-3zx1012-0ru11-1aa1 , power contactor- 3 phase 415v ac 3 pole 3 rt1036-1acoil voltage rating 110v ac , power contactor- 3 phase 415 v ac 3 pole 3 rt1023-1 a coil voltage rating 110 v ac , thermal overload relay- 3ru1926-3aa01 with 1 no. & 1 nc rating 11 to 16 a , thermal overload relay- 3ru1916-3aa01 with 1 no & 1 nc rating 1.5 to 2a , auxiliary contactor block no. l0120913, model no.- 3rh1921-1ca10 , auxiliary contactor block nc l0120917, model no:-3rh1921-1ca01 , make-schneider or equivalent , control traformer 250va 440v/110v/24v , power contractor auxiliary, model no.:- lc1d09, 3pole 415v ac/9a contract built in 1 no+1 nc , power contactor auxiliary, model no:- lc1d18, 3 pole 415v ac/18a up to7.5 kw, contactor inbuilt 1 no+1nc , thermal overload relay, electric lrd14 tesys d 7.0-10a , thermal over load relay lrd22 tesy 16-24a , power contactor, 3 phase 415 v ac 3 pole model no.-lc1d09 , smps, phaseo- abl1rem24062 (3ot29-660g) input: 100-120 vac, 5 amp., 200-240 vac, 2.5 amp., output-20 v dc, 6.25 a, 150 w (n998) , make-l&t or equivalent , power contactor 3 phase 415 v ac mnx 18 with 1 nc control 110 v ac , ad-on block mnx a1 2 no + 2 nc , ad-on block mnx a1 3 no + 1 nc , thermal overload relay, 2 to 3.3 a, mn-2-10a max., type-ss01214 , thermal overload relay- 3 to 5a, mn-2 max.-16 a , thermal overload relay, 4.5 to7.5 mn2 max.-25a
Tender For supply of goods, n & s aspirating type fire/smoke detection with alarm system to rdso specrdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part. relay card assembly with wiring, part no. cp-firelink-25/100rc input relay card, max.switching current 400ma at 24vdc,resistive load max.switchinh power 24w operating temparature -10 to +60 degree c relative humidity 0 to 90% [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of power circuit earth fault relay qop, type du to clw's spec. no. clw/es/r-27 (alt. z). [warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]