Get complete information related to latest Igniters Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Igniters Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Igniters Tenders.
Tender For sirsa town:- operation and maintenance of 20.00 mld stp based on sbr technology, including establishment, repair of mechanical parts i.e screens, manual screens, sluice gate complete at stp. repair and replacement of various pipes, repair of street lights and flood light i.e replacement of lamp chock, igniters and cable etc. civil structure i.e repair charges, lights, all electric wiring, all computer equipment`s, scada system, flow meter, analyzer, sensors, diffuser and all the other online monitoring system, consumable items, safety equipment`s, and chlorine gas, poly and all other works contingent thereto at stp kelina road sirsa town distt sirsa. (operation and maintenance for 3 years). -[dnit no.-148091]
Tender For supply of 2.2 kw ac crane drive , 5.5 kw ac crane drive , 11.0 kw ac crane drive , 22.0 kw ac crane drive , 37.0 kw ac crane drive , 55.0 kw ac crane drive , 75.0 kw ac crane drive 3 phase, digital ac crane drive 2.2 kw, ac drive should be suitable for heavy duty operation of 2.2 kw. offered ac drive should be suitable for crane-hoist operation. if, separate software required for crane application, it must be clubbed with supply of material. ac input voltage: 380 to 480v ac 10%, 3 phase, 3 wire, 50 hz; mode of control: bi-directional fully controlled 3-phase ac; speed regulation: 1% of base speed; braking: suitable dynamic braking resistance and chopper unit (external or in-built); acceleration time: 0.1 to 1000s or better; deacceleration time: 0.1 to 1000s or better; overload: 150%-1min, 200%-3.0s; ambient temperature: 0 to 50 c (derating shall not occur below 50 c. in the event that derating occurs below 50 c, the supplier shall provide a higher-rated drive to match the requirement); rated current at 50 c: min. current should be 5.5 amps at 50 c; high starting torque at low speed: 200% starting torque at 0.3 hz; two analog inputs: two nos. analog inputs having signal voltages of 0 to 10 vdc or 4 to 20 ma (configurable); two analog outputs: two nos. analog outputs having signal voltages of 0 to +/-10 vdc or 4 to 20 ma (configurable); six digital inputs: pnp/npn; one relay output: with short-circuit and overload protection; two digital outputs: with short- circuit and overload protection; brake release signals: outputs braking signals based on inverter operating conditions to prevent cargo bed rollback and overrunning; load adaptive control: when the actual load level is lower than the configured load level, the system can be operated at a ratio-multiplied speed (in terms of the configured frequency), resulting in significantly better efficiency; load ) /bid number : gem/2026/b/7563714 * /dated: 20-05-2026 & & / bid document 1 / 29 frequency), resulting in significantly better efficiency; load limiter: maintains the safety and rescuability of suspended loads by stopping when excessive torque is detected and by allowing operation only in the direction opposite to that in which the excessive load was detected; cooling capacity degradation alarm: detects and displays cooling capacity drop due to cooling fin clogging caused by dust and cooling fan airflow reduction; igbt life expectancy forecasting: estimates the power cycle life expectancy of the main circuit s igbt semiconductor device temperature due to frequent acceleration and deceleration stoppages, and displays the estimate before the design life is reached; protection: it must have all standard protections like stall protection, instantaneous power failure, single phasing, over voltage, under voltage, over current, inverter overload, thermal overload etc; display console: it must have alpha numeric display console for programming of drive, fault display and operating condition; dynamic qr code: it must have dynamic qr code for trouble shooting; tuning facility: it must have auto tuning facility. this must enable perfect matching of motor coupled to load with regards to optimum acceleration time, deceleration time, speed regulation etc; drive programming software: suitable drive programming software along with necessary connecting cable and adapter for connection with laptop and drive should be provided to get online with the offered drive (laptop not in scope); automatic voltage regulation: it must have automatic voltage regulation function to maintain high starting torque even at reduced voltage; regenerative option: it must be capable of regenerative operation; communication protocol: modbus (rtu/serial) or ethernet (tcp/ip); make of drives: fuji- electric/yasakawa/schneider/abb only; suitable dynamic breaking resistance unit of 60% wattage rating of drive, however the value of resistance is to be decided by manufacturer as per their technical manual for crane-ho
Tender For providing of custom bid for services - non comprehensive annual maintenance contract for hitachi make 1200kva variable frequency drives installed at iocl nrpl agra for preventive and breakdown maintenance
Tender For tmc package1 2026-27 - operation and maintenance of street lighting system 65w led lights complete with luminaries, lamps, control gear and an accessories . (excluding newly fixed fittings, which under maintainance period) ( for one year) specifications are specified as engineer charge work, supplying fixing led drivers suitable for 5700k led fitting outdoor fixtures.operating voltage range from180v to 265v, 50hzac power supply 150w 5700k suitable for outdoor led fitting pwd ele sr 2-23-24 p.no.53 it.no.12.52.6, supplying fixingleddriverssuitablefor5700kledfittingoutdoorfixtures.operatingvoltagerangefrom180vto265v,50hzac power supply 90w 5700k suitable for outdoor led fitting pwd ele sr 2-23-24 p.no.53 it.no.12.52.4, supplying fixingleddriverssuitablefor5700kledfittingoutdoorfixtures.operatingvoltagerangefrom180vto265v,50hzac power supply 40w 5700k suitable for outdoor led fitting pwd ele sr 2-23-24 p.no.53 it.no.12.52.2, operation and maintenance of street lighting systemsupply & replacing of 400 watts hpmh light accessories complete with chokes, igniters, lamps, control gear, control ropes, internal mast cable, etc complete for high mast lighting system. (excluding newly fixed fittings,) ( for one year)specifications are specified as engineer charge work, operation and maintenance of street lighting system poles with 250w hpsv lamps complete with luminaries, lamps, control gear and all accessories. (excluding newly fixed fittings, which are under maintainance period) ( for one year)
Tender For tmc package2 2026-27 - operation and maintenance of street lighting system 65w led lights complete with luminaries, lamps, control gear and an accessories . (excluding newly fixed fittings, which under maintainance period) ( for one year) specifications are specified as engineer charge work, supplying fixing led drivers suitable for 5700k led fitting outdoor fixtures.operating voltage range from180v to 265v, 50hzac power supply 150w 5700k suitable for outdoor led fitting pwd ele sr 2-23-24 p.no.53 it.no.12.52.6, supplying fixingleddriverssuitablefor5700kledfittingoutdoorfixtures.operatingvoltagerangefrom180vto265v,50hzac power supply 90w 5700k suitable for outdoor led fitting pwd ele sr 2-23-24 p.no.53 it.no.12.52.4, supplying fixingleddriverssuitablefor5700kledfittingoutdoorfixtures.operatingvoltagerangefrom180vto265v,50hzac power supply 40w 5700k suitable for outdoor led fitting pwd ele sr 2-23-24 p.no.53 it.no.12.52.2, operation and maintenance of street lighting systemsupply & replacing of 400 watts hpmh light accessories complete with chokes, igniters, lamps, control gear, control ropes, internal mast cable, etc complete for high mast lighting system. (excluding newly fixed fittings,) ( for one year)specifications are specified as engineer charge work, operation and maintenance of street lighting system poles with 250w hpsv lamps complete with luminaries, lamps, control gear and all accessories. (excluding newly fixed fittings, which are under maintainance period) ( for one year)s
Tender For tggenco ytps c andi unit4 assembling or dessembling , cleaning ,purging , testing, servicing, calibration and refixing of c and i equipments or instuments of main boiler , boiler auxiliaries id, fd, pa fans and lubeoil systems, blade pitch control dampers, guns and igniters, flame scanners, fuel oil valves and solenoids and instrumentation pertains to bowl mills,hot air and cold air gates of all mills, mill rejection system and gravimetric feeders, seal air and scanner air fans , sadcs power cylinders, smart positioners, transmitters, solenoid valves , limit switches, o2 analysers, aslds,seals replacement of pneumatic cylinders of had,cad,idf,paf,fdf dampers, burner tilt, movs pertaining to flue gas path gates and boiler valves, seperators and hwl valves, eco flow valves , bcw pumps, aph scaph system, soot blowing system, ervs, metal temperatures, flue gas temperatures, pressures and analysers and replacement of spare parts in unit 4 from commencement to 31.3.27
Tender For tender for supply, installation, testing and commissioning of variable frequency drives for various ahus installed at sbi samriddhi bhavan, lho kolkata