Get complete information related to latest Impedance Analyser Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Impedance Analyser Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Impedance Analyser Tenders.
Tender For bid to ras supply of setting upon lab infrastructure for keeping lab equipments - customized fabricated housing cabinet for 5 part hematology analyzer lxbxh 3x3x3 material used is resistant to chemical spills and corrosion , customized fabricated housing cabinet for fully automatic bio chemistry analyzer lxbxh 5x5x5 material used is resistant to chemical spills and corrosion , customized fabricated housing cabinet for semi automated urine analyzer lxbxh 2x2x2 material used is resistant to chemical spills and corrosion , customized fabricated housing cabinet for rpm rotospin test tube rotator lxbxh 2x2x2 material used is resistant to chemical spills and corrosion , electric cabling and earthing facility for 5 part hematology analyzer to avoid damage during power fluctuation , electric cabling and earthing facility for fully automatic bio chemistry analyzer to avoid damage during power fluctuation , electric cabling and earthing facility for semi automated urine analyzer to avoid damaged uring power fluctuation , electric cabling and earthing facility for rpm rotospin test tube rotator to avoid damaged uring power fluctuation , installation of bwm hdpe pipelines for disposal of bio waste fluids 5 part hematology analyzer , installation of bwm hdpe pipelines for disposal of bio waste fluids fully automatic bio chemistry analyzer , installation of bwm hdpe pipelines for disposal of bio waste fluids semi automated urine analyzer , installation of bwm hdpe pipelines for disposal of bio waste fluids rpm rotospin test tube rotator , customized fabrication of bio medical wastage unit
Tender For providing of calibration services - electrical, calibration for logic analyzer model no 16862a make keysight for 1 no; voltage, current, power (ac/dc); nabl labs; buyer premises (onsite),calibration services - electrical, calibration for triple o/p dc power supply model no e36313a make keysight for 2 nos; voltage, current, power (ac/dc); nabl labs; buyer premises (onsite),calibration services - electrical, calibration for waveform generator model no 33622a make keysight for 1 no; amplitude and frequency; nabl labs; buyer premises (onsite),calibration services - electrical, calibration for digital multi meter model no 34461a make keysight 2 nos; resistance, voltage, current, power (ac/dc); nabl labs; buyer premises (onsite)
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a