Tender For providing of operation and maintenance of electrical systems/electrical installations - annual job contract for operation and maintenance of e & m installations with fire fighting, fire alarm system, air conditioner units and allied works for non- operational are..
Tender For all in comprehensive maintenance contract for fire alarm detection systems installed at minister bungalow no 1 at minister site, gandhinagar
Tender For design, engineering, supply, installation, testing and commissioning of an alert, inform and direct system at six (6) sites - control & monitoring :- the control room shall be set up in the already constructed/available room at the pandoh dam area. this system should include a minimum 43-inch (hd) screen with an adjustable stand, capable of monitoring the operation of the siren station. it should display all feedback, including the status of being on or off, battery health, any faults etc. in the installed equipment. additionally, this system must have the capability to communicate directly with the control room to provide alerts and information in real time., for supply ,testing, designing, erection and commissioning of local station for alert, information and direct system comprising of the following hardware/software: panel/housing with power supply module. the controller, linked with all the control units through a communication and integration unit, displays the system via screens. the sirens should also be remote controlled. the control of the sirens should be according to the commands received from the remote central control station through a two-way gsm/gprs/3g/4g/lte and provision of vsat. security feature including intrusion alarm auxiliary/status control board for contact closure activation and status. the siren system should withstand outdoor environment condition & the siren assembly should be rust proof to withstand harsh and saline environmental condition. single point clicks activation & polling. status monitoring. complete configuration & reprogramming for control site. minimum 15,000 message alert notification through gsm/3g/4g/5g/lte/vsat to bbmb officials/ administrators and local residents according to requirement. programmable hot keys. communication over tcp/ip secure access with password. ethernet cable length :- the bidder shall be responsible for the supply and erection of all cabling required for the complete system, ensuring that the cables are of reputable make only and conform to the prescribed standards as per site requirements. rtu & software :- the r.t.u. and software as per the manufacturer`s design / program, the software should be suitable for controls up to 100+ sirens, the system can be expanded to accommodate changing needs. the software should be app and web based. communication between control centre and sirens. :- gsm/3g/4g/5g/lte network/vsat. pre-recorded voice messages :- live and pre-recorded voice messages in minimum 3 local languages i.e. (hindi, punjabi and english) strobe light :- high intensity led strobe light, color red, amber, green, 60-120 flashes per minute (adjustable), led life > 50000 hrs., pole/top mountable with 360 visibility preferably ip 66. alert tones & voice:- minimum 5 standard alert tones. support transmission of stored voice in siren/voice controller through wave file in memory card, remote activation. remote activation of alert tones and pre-recorded voices the voice messages will be customized, optimized for good quality for the intended location, language preferably in punjabi, hindi & english. warranty period:- 3 years., input power source :- the quantity of solar photovoltaic panels and batteries shall be adequate to meet the systems operational requirements. only reputed manufacturers such as tata solar, vikram, waaree, reil, or equivalent brands shall be supplied. the solar panel input source shall be integrated with the required number of batteries to run the installed system continuously for a minimum duration of three (3) days under idle running conditions. this includes six (6) operational cycles per day, with each cycle lasting a minimum of twenty (20) minutes. a secondary provision for electrical input supply shall be provided to enable system operation in the event of solar panel failure or insufficiency beyond the designed power supply capacity., siren type :- bi-directional electronic siren pre-programmed audio amp
Tender For agencies for the repair works for electrical systems mentioned below provided for 73 nos. of buildings on land bearing- repair work of 3.5 mld stp plant with electrical and mechanical equipments. repair work of 3.5 mld stp plant with electrical and mechanical equipments. repairing of fire alarm public address system of 73 nos. of buildings. providing lg make tv units-32 inch & sounder music system of 73 nos. of buildings. ,intercom repair & service work of 73 nos. of buildings. ,cctv repairing work completely of 73 nos. of buildings. ,supplying & installation of 3 m high (clear height) single arm & double arm decorative ,garden light pole with 50 watt led fittings with required accessories in provided concrete structure. ,providing & installation of lift door banging controller.
Tender For corrigendum : e-tender modernisation of branch office own premises including civil works, interior works, modular furniture, chairs, electrical installation, data and telephone cabling,fire alarm systems, air conditioning work at manjeri under kozhikode division
Tender For corrigendum : repairs maintenance to fire fighting system fire hydrants fire alarm systems control panels and lt panel lt cable and connected miscellaneous items at phase ii residential area under ge i r and d east bangalore
Tender For corrigendum : tender for supply of resistance temperature transmitter and indicator - resistance temperature transmitter ( resistance to current converter) , make -elektra precision .input- rtd pt-200. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-1.(bidder should comply one to one in specification as attached) , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd pt.200. temp range- 230 - 320 degree centigrade. o/p- 04 to 20 ma dc. single output. other common details as per attached annexure-1. , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd-pt.200. temp range- 0-320 degree centigrade. output- 04 to 20 ma dc with double isolated outputs. other common details as per attached annexure-1. , resistance temperature transmitter ( resistance to current converter) , make-elektra precision .input- rtd pt-100. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-2.(bidder should comply one to one in specification as attached) , indicatingalarmmeter , make - m/s elektra precision systems , tag-flow indicatingalarmmeter , range-0-400 ft/sec , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicatingalarmmeter , make - m/s elektra precision systems , tag-temperature indicatingalarmmeter , range-0-100 degree c , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicatingalarmmeter , make - m/s elektra precision systems , tag- differential pressure indicatingalarm , range- -15 to +25 gm/cm2 , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicatingalarmmeter , make - m/s elektra precision systems , tag- flow indicatingalarm , range- 0-700 (squre root scale flow) lpm , alarm -low , alarm relay-one for low alarm , input -10-50ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicatingalarmmeter , make - m/s elektra precision systems , tag- temperature indicatingalarm , range- 0 to 70 degree c , alarm -low/high , alarm relay-one for high alarm and one for low alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicatingalarmmeter , make - m/s elektra precision systems , tag- flow indicatingmeter , range- 0-6 (squre root scale) klpm , alarm -no alarm , alarm relay-no alarm , input -10-50 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicatingalarmmeter , make - m/s elektra precision systems , tag- level indicatingmeter , range- 0-10 meter , alarm -no alarm , alarm relay-no alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicatingalarmmeter , make - m/s elektra precision systems , tag- flow indicatingmeter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicatingalarmmeter , make - m/s elektra precision systems , tag- flow indicatingmeter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -0-4 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicatingalarmmeter , make - m/s elektra precision systems , tag- pressure indicatingalarmmeter , range- 0-0.7 kg/cm2 , alarm -high/low , alarm relay-one for high alarm & one for low alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , i
Tender For providing of custom bid for services - 44151395 annual maintenance contract for a period of two years for fire detection & alarm and gas suppressions systems across the engine division, as listed in the annexure-1 , as per scope of work and terms & conditions enc..,custom bid for services - 44151395 charges for refilling of fire supression system gas cylinders including hydraulic pressure testing, painting and transportation as per annexure-4,custom bid for services - 44151395 probables list of spares as per annexure-5
Tender For part b supply of material for comprehensive operation and maintenance of firefighting and fire alarm systems installed at engineering hub building for two years